2CSB203001R1250 ABB DDA203 AC-25/0.03 RCD Block 3P 25 A 30 mA Type AC

2CSB203001R1250 ABB DDA203 AC-25/0.03 RCD Block 3P 25 A 30 mA Type AC

ABB DDA203 AC-25/0.03 is a 3-pole Type AC residual current device block rated at 25 A with 30 mA sensitivity and 230/400 V AC operation for residential, commercial and industrial circuit protection.

SKU: 2CSB203001R1250Alt SKU: DDA203AC250.03MPN: 2CSB203001R1250
Price
List Price £173.54 ex VAT
Your Price (ex VAT) Save 35%
£112.80 35% OFF
You save £60.74 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £112.80
Trade pricing is personalised to your account

Manufacturer Lead Time

£112.80

Why Choose the ABB DDA203 AC-25/0.03 RCD Block?

The ABB DDA203 AC-25/0.03 is a 3-pole Type AC residual current device (RCD) block designed for assembly with compatible ABB miniature circuit breakers. Part of the ABB DDA200 RCD series, it combines a 25 A rated current with sensitive 30 mA residual-current protection for residential, commercial and industrial electrical installations.

Its Type AC characteristic responds to sinusoidal alternating earth fault currents. With a rated residual current of 30 mA, the DDA203 AC-25/0.03 provides protection against indirect contact together with additional protection against direct contact when correctly selected and installed as part of the electrical protection system.

The DDA203 is designed for on-site assembly with compatible ABB S200 series and S300P miniature circuit breakers. The resulting assembly combines residual-current protection from the DDA200 block with overload and short-circuit protection from the associated circuit breaker, providing a compact modular protection solution.

Key Advantages

  • 30 mA residual-current sensitivity for sensitive earth leakage detection and additional protection against electric shock.
  • Type AC protection against sinusoidal alternating residual currents.
  • 25 A rated current for compatible electrical distribution circuits.
  • 3-pole configuration for three-pole circuit protection arrangements.
  • Designed for assembly with compatible ABB S200 series and S300P MCBs.
  • Suitable for residential, commercial and industrial applications.

Key Features

  • ABB DDA200 RCD series.
  • 3-pole Type AC RCD block.
  • 25 A rated current.
  • 30 mA rated residual current.
  • 230/400 V AC rated voltage.
  • 50–60 Hz rated frequency.
  • 500 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • Instantaneous operating characteristic.
  • 3 W power loss.

30 mA Type AC Residual-Current Protection

Type AC residual-current devices are designed to detect sinusoidal alternating earth fault currents. The ABB DDA203 AC-25/0.03 therefore provides residual-current protection for circuits where the connected loads and applicable installation requirements permit the use of Type AC protection.

Its 30 mA sensitivity provides protection against indirect contact and additional protection against direct contact. When assembled with a compatible ABB miniature circuit breaker, the DDA203 forms a coordinated protection arrangement combining residual-current detection with overload and short-circuit protection.

Typical Applications

  • Residential electrical distribution systems.
  • Commercial building electrical installations.
  • Industrial electrical distribution systems.
  • Three-pole circuits requiring 30 mA residual-current protection.
  • Circuits with sinusoidal AC residual-current characteristics.
  • Electrical distribution boards.
  • Control panels and modular DIN-rail equipment.
  • Combined RCD and MCB assemblies using compatible ABB circuit breakers.

Technical Specifications

Series DDA200
SKU DDA203AC250.03
Order code 2CSB203001R1250
EAN 8012542792505
Product type Residual current device (RCD) block
Residual-current type Type AC
Leakage current type AC
Number of poles 3
Rated current 25 A
Rated residual current 30 mA
Rated voltage 230/400 V AC
Rated operational voltage 230/400 V AC
Rated frequency 50–60 Hz
Rated insulation voltage 500 V
Rated impulse withstand voltage 4 kV
Operating characteristic Instantaneous
Residual-current waveform Sinusoidal AC
Power loss 3 W
Electrical endurance 10,000 cycles
Degree of protection IP2X
Standard IEC/EN 61009 Annex G
Modular width 5 DIN modules
Dimensions (W × H × D) 122 × 93 × 76 mm
Catalogue weight 0.22 kg

Frequently Asked Questions

What is the ABB DDA203 AC-25/0.03 used for?

The DDA203 AC-25/0.03 is a 3-pole Type AC RCD block designed for assembly with compatible ABB miniature circuit breakers to provide 30 mA residual-current protection in residential, commercial and industrial electrical installations.

What residual-current sensitivity does the DDA203 AC-25/0.03 provide?

The device has a rated residual current of 30 mA, providing sensitive earth leakage detection, protection against indirect contact and additional protection against direct contact.

What does Type AC mean on the DDA203 AC-25/0.03?

Type AC means the RCD block is designed to respond to sinusoidal alternating residual currents. The suitability of Type AC protection should be determined according to the connected equipment and applicable electrical installation requirements.

What voltage is the ABB DDA203 AC-25/0.03 rated for?

The DDA203 AC-25/0.03 has a rated and rated operational voltage of 230/400 V AC and a rated frequency of 50–60 Hz.

Is the DDA203 AC-25/0.03 a complete RCBO on its own?

No. The DDA203 AC-25/0.03 is an RCD block designed for assembly with a compatible ABB miniature circuit breaker. The DDA203 provides residual-current protection, while the associated circuit breaker provides overload and short-circuit protection.

Trusted ABB Circuit Protection

ABB DDA200 residual current device blocks provide modular earth leakage protection for residential, commercial and industrial installations, combining with compatible ABB miniature circuit breakers to create coordinated residual-current, overload and short-circuit protection assemblies.