ABB DDA202AS630.5 DDA202 A S-63/0.5 is a 2-pole 63 A 500 mA Type A selective residual current device block designed for coordinated earth-fault protection with compatible ABB miniature circuit breakers.
£121.88
The ABB DDA202AS630.5, manufacturer type DDA202 A S-63/0.5, is a 2-pole Type A selective residual current device (RCD) block designed for combination with compatible ABB miniature circuit breakers. Part of the ABB DDA200 RCD series, it provides residual-current protection with a selective time-delay characteristic for coordinated electrical distribution systems.
The DDA202 A S-63/0.5 is designed to detect sinusoidal alternating and pulsating DC residual currents. Its selective S characteristic introduces an intentional operating delay, helping achieve discrimination with suitable downstream instantaneous residual-current devices and reducing unnecessary interruption of upstream circuits.
With a rated current of 63 A, a rated residual operating current of 500 mA and a 2-pole configuration, the DDA202AS630.5 is suitable for commercial and industrial distribution systems requiring selective Type A earth-fault protection. Its modular construction enables integration with compatible ABB miniature circuit breakers for combined residual-current and overcurrent protection.
Selective residual current protection is used where coordinated operation between upstream and downstream protective devices is required. The intentional operating delay of the ABB DDA202 A S-63/0.5 allows a suitable downstream instantaneous residual-current device to respond first to a local earth fault, helping maintain power to unaffected parts of the installation.
As a Type A device, the DDA202AS630.5 responds to both sinusoidal alternating and pulsating DC residual currents. Combined with a compatible ABB miniature circuit breaker, the DDA200 modular design provides a coordinated solution for residual-current and overcurrent protection in modern electrical distribution systems.
| Series | DDA200 |
|---|---|
| SKU | DDA202AS630.5 |
| ABB order code | 2CSB202201R4630 |
| Product type | Selective residual current device block / RCD block |
| Residual-current type | Type A |
| Operating characteristic | Selective (S) |
| Number of poles | 2 |
| Rated current | 63 A |
| Rated residual operating current | 500 mA |
| Rated voltage | 230/400 V AC |
| Rated frequency | 50–60 Hz |
| Rated insulation voltage | 500 V |
| Rated impulse withstand voltage | 4 kV |
| Protection rating | IP2X |
| Standard | IEC/EN 61009 Annex G |
The ABB DDA202AS630.5 is a selective Type A RCD block designed for combination with compatible ABB miniature circuit breakers to provide coordinated residual-current protection.
The ABB DDA202 A S-63/0.5 has a rated current of 63 A.
The DDA202 A S-63/0.5 has a rated residual operating current of 500 mA.
The selective S characteristic provides an intentional operating delay to help coordinate the RCD block with suitable downstream instantaneous residual-current devices.
As a Type A device, it is designed to detect sinusoidal alternating residual currents and pulsating DC residual currents.