2CDS272527R0357 ABB SU202DC-K5 5A 2-Pole Type K 14kA DC Miniature Circuit Breaker

2CDS272527R0357 ABB SU202DC-K5 5A 2-Pole Type K 14kA DC Miniature Circuit Breaker

ABB SU202DC-K5 is a 5 A two-pole Type K DC miniature circuit breaker with a 14 kA UL 489 short-circuit current rating, designed for reliable overload and short-circuit protection in commercial and industrial DC circuits.

SKU: 2CDS272527R0357Alt SKU: SU202DCK5MPN: 2CDS272527R0357
Price
List Price £191.19 ex VAT
Your Price (ex VAT) Save 25%
£143.39 25% OFF
You save £47.80 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £143.39
Trade pricing is personalised to your account

Manufacturer Lead Time

£143.39

Why Choose the ABB SU202DC-K5 Miniature Circuit Breaker?

The ABB SU202DC-K5 is a two-pole miniature circuit breaker (MCB) developed specifically for direct-current circuit protection. Part of ABB's SU200DC series, this model combines a 5 A rated current, Type K tripping characteristic and 14 kA short-circuit current rating for demanding commercial and industrial DC installations.

The SU202DC-K5 provides two complementary protection mechanisms: delayed thermal tripping for overload protection and electromechanical tripping for short-circuit protection. Designed for DC circuits up to 250 V DC, it provides robust branch-circuit protection while retaining the compact modular format associated with ABB System pro M compact devices.

Its Type K characteristic is particularly suited to motors, transformers, control equipment and other loads that can produce elevated functional peak currents. The SU202DC-K5 complies with UL 489 and CSA 22.2 No. 5 and provides a high 14 kA SCCR, making it a dependable solution for professional DC distribution and equipment protection.

Key Advantages

  • 14 kA short-circuit current rating (SCCR) according to UL 489.
  • 5 A rated current for low-current DC circuits.
  • Two-pole configuration with two protected poles.
  • Type K tripping characteristic suited to loads with elevated starting or peak currents.
  • Designed specifically for direct-current circuit protection.
  • Suitable for operation up to 250 V DC.
  • Thermal protection against overloads and electromechanical protection against short circuits.
  • UL 489 and CSA 22.2 No. 5 compliance for commercial and industrial applications.

Key Features

  • ABB SU200DC series miniature circuit breaker.
  • 5 A rated current.
  • 2-pole configuration.
  • 2 protected poles.
  • Type K tripping characteristic.
  • 14 kA SCCR according to UL 489.
  • Designed for DC circuits up to 250 V DC.
  • Delayed thermal overload tripping mechanism.
  • Electromechanical short-circuit tripping mechanism.
  • 250 V rated insulation voltage (Ui).
  • 3 kV rated impulse withstand voltage (Uimp).
  • Energy limiting class 3.
  • Overvoltage category III.
  • Pollution degree 3.
  • IP20 protection rating.
  • Additional auxiliary equipment can be fitted.
  • ABB order code 2CDS272527R0357.

Reliable Protection for Demanding DC Circuits

The ABB SU202DC-K5 protects cables, conductors and connected equipment against excessive current caused by overload and short-circuit conditions. Its delayed thermal mechanism responds to sustained overloads, while the electromechanical trip mechanism provides rapid interruption under short-circuit conditions. The 14 kA SCCR provides substantial fault-current capability for demanding DC installations.

The Type K characteristic accommodates the elevated functional peak currents associated with motors, transformers and similar equipment while retaining effective overcurrent protection. Combined with its two-pole construction, compact two-module width and operation up to 250 V DC, the SU202DC-K5 is well suited to industrial automation, auxiliary distribution and other professional DC applications. Correct device polarity must be observed when installed in DC circuits.

Typical Applications

  • Industrial DC distribution systems.
  • Commercial DC electrical installations.
  • DC motor circuits.
  • Transformer and inductive-load circuits.
  • Control and automation equipment.
  • DC auxiliary circuits.
  • Low-current DC branch-circuit protection.
  • DC electrical panels and distribution assemblies.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Series SU200DC
ABB order code 2CDS272527R0357
EAN 4053546176940
Product type Miniature circuit breaker (MCB)
Product group DC / Traction MCB
Number of poles 2
Number of protected poles 2
Rated current 5 A
Tripping characteristic K
Short-circuit current rating (SCCR) 14 kA according to UL 489
DC operating voltage up to 250 V DC
Rated insulation voltage (Ui) 250 V
Rated impulse withstand voltage (Uimp) 3 kV
Energy limiting class 3
Overvoltage category III
Pollution degree 3
Degree of protection IP20
Operating ambient temperature -20 to +55 °C
Solid conductor capacity 0.75–35 mm²
Multi-wired conductor capacity 0.75–25 mm²
Installation depth 69 mm
Width 2 modular units
Power loss 2.2 W
Auxiliary equipment Additional devices can be fitted
Standards UL 489, CSA 22.2 No. 5

Frequently Asked Questions

What is the ABB SU202DC-K5 used for?

The ABB SU202DC-K5 is a two-pole DC miniature circuit breaker designed to protect cables, conductors and connected equipment against overloads and short circuits in commercial and industrial DC applications.

What is the rated current of the SU202DC-K5?

The SU202DC-K5 has a rated current of 5 A and features two protected poles.

What does the Type K tripping characteristic mean?

The Type K characteristic is particularly suitable for motors, transformers and other circuits where elevated functional peak or starting currents can occur during normal operation.

What is the short-circuit rating of the ABB SU202DC-K5?

The SU202DC-K5 has a 14 kA short-circuit current rating (SCCR) according to UL 489 and is designed for DC operation up to 250 V DC.

What is the ABB order code for the SU202DC-K5?

The ABB order code for this specific 5 A, two-pole Type K DC MCB is 2CDS272527R0357.

Trusted DC Circuit Protection from ABB

ABB SU200DC miniature circuit breakers provide robust overload and short-circuit protection for commercial and industrial DC systems, combining high short-circuit capability with application-specific tripping characteristics and compact modular construction.