2CDS272447R0607 ABB S202MTR-K63 63A 2-Pole Type K Miniature Circuit Breaker

2CDS272447R0607 ABB S202MTR-K63 63A 2-Pole Type K Miniature Circuit Breaker

ABB S202MTR-K63 is a 63 A 2-pole Type K miniature circuit breaker with 10 kA DC ultimate short-circuit breaking capacity, designed for overload and short-circuit protection in rolling stock and traction electrical systems.

SKU: 2CDS272447R0607Alt SKU: S202MTRK63MPN: 2CDS272447R0607
Price
List Price £396.66 ex VAT
Your Price (ex VAT) Save 25%
£297.50 25% OFF
You save £99.17 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £297.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£297.50

Why Choose the ABB S202MTR-K63 Miniature Circuit Breaker?

The ABB S202MTR-K63 is a high-performance 2-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits in demanding rolling stock, traction and industrial electrical applications. As part of the specialised ABB S 200 MTR series, it combines robust circuit protection with ring-tongue connections developed for secure electrical installations in railway environments.

This miniature circuit breaker features a Type K tripping characteristic, making it particularly suitable for circuits supplying equipment with relatively high starting or inrush currents. Its two-pole configuration provides simultaneous circuit protection across two conductors, while the S 200 MTR construction is engineered to withstand demanding vibration, shock and environmental conditions encountered in rolling stock.

With a rated current of 63 A and a 10 kA DC ultimate short-circuit breaking capacity, the S202MTR-K63 provides dependable protection for higher-current distribution and auxiliary circuits. For ratings above 25 A, the S 200 MTR range also provides an AC ultimate short-circuit breaking capacity of 15 kA according to IEC/EN 60947-2.

Key Advantages

  • Specialised miniature circuit breaker for rolling stock and traction applications.
  • 63 A rated current for higher-current circuit protection.
  • 2-pole configuration for simultaneous protection of two conductors.
  • Type K tripping characteristic suitable for loads with higher starting currents.
  • 10 kA DC ultimate short-circuit breaking capacity.
  • 15 kA AC ultimate short-circuit breaking capacity according to IEC/EN 60947-2.
  • Special ring-tongue connection for secure electrical termination.
  • Designed for demanding environments with high resistance to vibration and shock.

Key Features

  • ABB S 200 MTR series miniature circuit breaker.
  • 63 A rated current.
  • 2 protected poles.
  • K characteristic tripping curve.
  • 10 kA DC ultimate breaking capacity.
  • 15 kA AC ultimate breaking capacity.
  • Short-circuit tested to 10 kA according to IEC/EN 60898.
  • Special ring-tongue terminal connection.
  • Operating temperature range from -40 °C to +75 °C.
  • Railway fire and smoke compliant housing materials.

Reliable Circuit Protection for Rolling Stock and Traction Systems

Miniature circuit breakers such as the ABB S202MTR-K63 automatically interrupt a circuit when excessive current caused by an overload or short circuit occurs. This helps protect cables, connected equipment and electrical distribution systems from damaging fault currents while allowing the circuit breaker to be reset after the cause of the fault has been corrected.

The ABB S 200 MTR range is specifically developed for railway applications and combines high short-circuit performance with resistance to vibration, shock and extreme temperatures. Its Type K characteristic and secure ring-tongue connections make the S202MTR-K63 particularly suitable for demanding electrical circuits in rolling stock and traction equipment.

Typical Applications

  • Railway rolling stock electrical systems.
  • Traction electrical distribution equipment.
  • Train auxiliary power circuits.
  • Higher-current equipment protection.
  • Circuits supplying loads with elevated starting currents.
  • Protection of long-cable AC systems.
  • DC electrical circuits with appropriate polarity configuration.
  • Industrial transportation and automation equipment.

Technical Specifications

Series S 200 MTR
ABB order code 2CDS272447R0607
Product type Miniature circuit breaker (MCB)
Product group DC / Traction MCB
Rated current 63 A
Number of poles 2
Tripping characteristic Type K
DC ultimate short-circuit breaking capacity 10 kA
AC ultimate short-circuit breaking capacity 15 kA
IEC/EN 60898 short-circuit rating 10 kA
Terminal type Ring-tongue connection
Operating temperature -40 °C to +75 °C
Dimensions per pole (H × D × W) 85 × 69 × 17.5 mm
Weight approx. 0.250 kg
Product standard IEC/EN 60947-2
Railway fire protection EN 45545-2
Railway vibration and shock IEC/EN 61373

Frequently Asked Questions

What is the ABB S202MTR-K63 used for?

The ABB S202MTR-K63 is a 2-pole miniature circuit breaker used to protect electrical circuits against overloads and short circuits, particularly in rolling stock, railway and traction applications.

What is the rated current of the S202MTR-K63?

The S202MTR-K63 has a rated current of 63 A.

What tripping characteristic does this MCB use?

The S202MTR-K63 uses a Type K tripping characteristic, making it suitable for circuits supplying equipment that can produce relatively high starting or inrush currents.

What is the breaking capacity of the ABB S202MTR-K63?

The S202MTR-K63 provides an ultimate short-circuit breaking capacity of 10 kA DC and 15 kA AC according to IEC/EN 60947-2.

Is the S202MTR-K63 designed for railway applications?

Yes. The ABB S 200 MTR series is specifically designed for rolling stock and railway applications, with ring-tongue connections and compliance with relevant fire, smoke, vibration and shock requirements.

Trusted Circuit Protection from ABB

ABB S 200 MTR miniature circuit breakers provide specialised overload and short-circuit protection for demanding rolling stock and traction electrical systems, combining high breaking capacity, secure ring-tongue connections and robust railway-oriented construction.