2CDS272447R0407 ABB S202MTR-K8 8A 2-Pole Type K 10kA Miniature Circuit Breaker

2CDS272447R0407 ABB S202MTR-K8 8A 2-Pole Type K 10kA Miniature Circuit Breaker

ABB S202MTR-K8 is an 8 A two-pole Type K 10 kA miniature circuit breaker designed for reliable overload and short-circuit protection in railway, rolling stock and traction electrical systems.

SKU: 2CDS272447R0407Alt SKU: S202MTRK8MPN: 2CDS272447R0407
Price
List Price £357.31 ex VAT
Your Price (ex VAT) Save 25%
£267.98 25% OFF
You save £89.33 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £267.98
Trade pricing is personalised to your account

Manufacturer Lead Time

£267.98

Why Choose the ABB S202MTR-K8 Miniature Circuit Breaker?

The ABB S202MTR-K8 is a specialised two-pole miniature circuit breaker (MCB) designed to provide dependable overload and short-circuit protection in railway, rolling stock and traction electrical systems. Part of the ABB S200 MTR series, this model combines an 8 A rated current, Type K tripping characteristic and 10 kA rated short-circuit capacity.

The S200 MTR range is engineered for demanding railway electrical installations and provides protection for conductors and connected equipment against excessive current. The S202MTR-K8 uses thermal-magnetic protection and a two-pole configuration, allowing both poles to be disconnected when an overload or short-circuit condition requires circuit interruption.

Its Type K characteristic is particularly suitable for circuits supplying inductive loads and equipment that can produce increased starting currents, including motors, transformers and control equipment. Railway-oriented construction and secure ring-tongue connections make the S202MTR-K8 a practical choice for onboard auxiliary and equipment circuits, with ABB order code 2CDS272447R0407 identifying this exact model.

Key Advantages

  • Designed for railway, rolling stock and traction electrical applications.
  • 8 A rated current with two-pole circuit protection.
  • Type K tripping characteristic suited to loads with increased starting currents.
  • 10 kA rated short-circuit capacity for robust fault protection.
  • Thermal-magnetic operation provides overload and short-circuit protection.
  • Suitable for motors, transformers and other inductive loads.
  • Special ring-tongue terminal arrangement supports secure railway wiring.
  • Compact modular construction facilitates integration into rolling stock electrical equipment.

Key Features

  • ABB S200 MTR series miniature circuit breaker.
  • 8 A rated current.
  • 2-pole configuration.
  • Type K tripping characteristic.
  • 10 kA rated short-circuit capacity.
  • Thermal-magnetic overcurrent protection.
  • Designed for railway and rolling stock electrical systems.
  • Ring-tongue terminal connection for secure conductor termination.
  • Suitable for inductive loads with increased starting currents.
  • Compact modular construction.
  • ABB order code 2CDS272447R0407.

Reliable Protection for Railway and Inductive Loads

The ABB S202MTR-K8 protects electrical conductors and connected equipment against excessive current caused by overloads and short circuits. Its thermal protection responds to sustained overload conditions, while the magnetic mechanism provides rapid interruption when a high short-circuit current occurs.

The Type K characteristic allows the breaker to accommodate the increased starting currents associated with many inductive loads while maintaining effective fault protection. Combined with the railway-oriented S200 MTR construction and ring-tongue connection system, this makes the S202MTR-K8 well suited to demanding rolling stock control, auxiliary and equipment circuits.

Typical Applications

  • Railway rolling stock electrical systems.
  • Traction auxiliary electrical circuits.
  • Train control and equipment cabinets.
  • Electric motor circuits.
  • Transformers and inductive loads.
  • Control and automation equipment.
  • Onboard auxiliary power systems.
  • Railway electrical distribution and protection assemblies.

Technical Specifications

Series S200 MTR
ABB order code 2CDS272447R0407
Product type Miniature circuit breaker (MCB)
Product group DC / Traction MCB
Number of poles 2
Rated current 8 A
Tripping characteristic K
Rated short-circuit capacity 10 kA
Protection principle Thermal-magnetic
Connection type Ring-tongue terminal
Application Railway / rolling stock / traction circuit protection

Frequently Asked Questions

What is the ABB S202MTR-K8 used for?

The ABB S202MTR-K8 is a two-pole miniature circuit breaker designed to protect electrical circuits against overload and short-circuit faults, particularly in railway, rolling stock and traction applications.

What is the rated current of the S202MTR-K8?

The S202MTR-K8 has a rated current of 8 A.

What does the Type K tripping characteristic mean?

The Type K characteristic is suited to circuits containing motors, transformers and other inductive loads that can produce increased starting or inrush currents during normal operation.

What is the breaking capacity of the ABB S202MTR-K8?

The S202MTR-K8 is specified with a rated short-circuit capacity of 10 kA.

What is the ABB order code for the S202MTR-K8?

The ABB order code for this specific 8 A, two-pole Type K MCB is 2CDS272447R0407.

Trusted Protection for Railway Electrical Systems

ABB S200 MTR miniature circuit breakers provide dependable overload and short-circuit protection for rolling stock and traction electrical systems, combining application-specific tripping characteristics with secure railway-oriented connections.