2CDS272334R0981 ABB ST202M-D0.5 0.5 A 2-Pole Type D Miniature Circuit Breaker

2CDS272334R0981 ABB ST202M-D0.5 0.5 A 2-Pole Type D Miniature Circuit Breaker

ABB ST202M-D0.5 is a 0.5 A 2-pole Type D miniature circuit breaker from the ST200M series designed for reliable UL 1077 supplementary overload and short-circuit protection of low-current industrial electrical circuits with high-inrush loads.

SKU: 2CDS272334R0981Alt SKU: ST202MD0.5MPN: 2CDS272334R0981
Price
List Price £82.20 ex VAT
Your Price (ex VAT) Save 25%
£61.65 25% OFF
You save £20.55 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £61.65
Trade pricing is personalised to your account

Manufacturer Lead Time

£61.65

Why Choose the ABB ST202M-D0.5 Miniature Circuit Breaker?

The ABB ST202M-D0.5 is a high-performance 2-pole miniature circuit breaker (MCB) designed to provide reliable supplementary overcurrent and short-circuit protection for low-current industrial electrical equipment and circuits. As part of the robust ABB ST200M series, it combines a 0.5 A rated current with a Type D tripping characteristic for circuits that may experience high starting or inrush currents relative to their normal operating current.

Designed for supplementary protection in accordance with UL 1077, the ST202M-D0.5 uses thermal-magnetic operation to disconnect protected circuits during overload and short-circuit conditions. Its Type D characteristic provides increased tolerance of normal inrush currents while maintaining dependable protection against sustained overcurrent and fault conditions.

With two protected poles, a rated current of 0.5 A and a Type D characteristic, this breaker is well suited to low-current industrial control and equipment circuits where transient starting currents need to be accommodated. ABB order code 2CDS272334R0981 provides precise product identification for specification, procurement and replacement.

Key Advantages

  • Reliable 2-pole supplementary circuit protection for industrial electrical equipment.
  • 0.5 A rated current suitable for low-current equipment and control circuits.
  • Type D tripping characteristic suited to circuits with high starting or inrush currents.
  • Designed for supplementary protection in accordance with UL 1077.
  • Thermal-magnetic protection against overload and short-circuit conditions.
  • Compact modular construction simplifies DIN-rail installation in control panels.

Key Features

  • ABB ST200M miniature circuit breaker series.
  • 2-pole configuration.
  • 0.5 A rated current.
  • Type D tripping characteristic.
  • 15 kA short-circuit breaking capacity.
  • Thermal-magnetic overcurrent protection.
  • UL 1077 supplementary protector classification.
  • Compact modular format for DIN-rail mounting.

Reliable Protection for Low-Current High-Inrush Circuits

Miniature circuit breakers such as the ABB ST202M-D0.5 automatically disconnect protected circuits when excessive current results from an overload or short circuit. Unlike a fuse, the breaker can be reset after the electrical fault has been identified and corrected, helping simplify maintenance and reduce replacement requirements in industrial equipment.

The Type D operating characteristic provides increased tolerance of high instantaneous starting currents compared with characteristics intended for lower-inrush loads. Combined with the ST200M series' compact modular construction and high breaking capacity, this makes the ST202M-D0.5 a practical supplementary protection device for low-current industrial circuits where transient inrush conditions are expected.

Typical Applications

  • Industrial control panels and automation equipment.
  • Low-current circuits with elevated starting or inrush currents.
  • Control and auxiliary equipment circuits.
  • Industrial machinery and OEM equipment.
  • Equipment protection circuits.
  • Supplementary circuit protection where UL 1077 devices are specified.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 1077
Series ST200M
ABB order code 2CDS272334R0981
Product type Miniature circuit breaker / supplementary protector
Number of poles 2
Rated current 0.5 A
Tripping characteristic Type D
Short-circuit breaking capacity 15 kA
Protection principle Thermal-magnetic
UL classification UL 1077 supplementary protector
Mounting DIN rail
Modular width 2 modules

Frequently Asked Questions

What is the ABB ST202M-D0.5 used for?

The ABB ST202M-D0.5 is a 2-pole miniature circuit breaker designed to provide supplementary overload and short-circuit protection for low-current industrial electrical circuits, particularly where high starting or inrush currents may occur.

What is the rated current of the ST202M-D0.5?

The ST202M-D0.5 has a rated current of 0.5 A.

What tripping characteristic does the ST202M-D0.5 use?

The breaker uses a Type D tripping characteristic, making it suitable for circuits that can experience high normal starting or inrush currents.

What is the short-circuit breaking capacity of the ST202M-D0.5?

The ST202M-D0.5 has a specified short-circuit breaking capacity of 15 kA.

What is the ABB order code for the ST202M-D0.5?

The ABB order code for the ST202M-D0.5 is 2CDS272334R0981.

Trusted ABB Circuit Protection