2CDS272011R0024 ABB SH202M-C2 MCB 10kA 2P Type C 2A

2CDS272011R0024 ABB SH202M-C2 MCB 10kA 2P Type C 2A

ABB SH202M-C2 is a 2 A two-pole Type C miniature circuit breaker with 10 kA short-circuit breaking capacity for reliable overload and short-circuit protection in electrical distribution and control applications.

SKU: 2CDS272011R0024Alt SKU: SH202MC2MPN: 2CDS272011R0024
Price
List Price £67.92 ex VAT
Your Price (ex VAT) Save 25%
£50.94 25% OFF
You save £16.98 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £50.94
Trade pricing is personalised to your account

Manufacturer Lead Time

£50.94

Why Choose the ABB SH202M-C2 Miniature Circuit Breaker?

The ABB SH202M-C2 is a compact and reliable two-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits. As part of the ABB SH200M MCB series, it provides dependable thermal-magnetic circuit protection for residential, commercial and similar electrical installations.

Featuring a 2 A rated current, Type C tripping characteristic and 10 kA short-circuit breaking capacity, the SH202M-C2 is well suited to low-current circuits where moderate starting or inrush currents may occur. Its Type C characteristic provides effective fault protection while accommodating the normal start-up behaviour of suitable electrical loads.

The two-pole configuration enables simultaneous switching and protection of two conductors, making the SH202M-C2 suitable for applications requiring coordinated two-pole disconnection. Its compact modular construction and standard DIN-rail mounting allow straightforward integration into electrical distribution boards and control panels.

Key Advantages

  • Reliable overload and short-circuit protection for electrical circuits.
  • 2 A rated current suitable for low-current distribution and control applications.
  • Type C tripping characteristic accommodates moderate starting and inrush currents.
  • 10 kA short-circuit breaking capacity provides robust fault protection.
  • Two-pole configuration provides simultaneous switching and protection of two conductors.
  • Standard DIN-rail mounting simplifies installation in distribution boards and control panels.

Key Features

  • ABB SH200M miniature circuit breaker series.
  • 2 A rated current.
  • Two poles (2P).
  • Type C tripping characteristic.
  • 10 kA short-circuit breaking capacity.
  • 400 V AC rated operational voltage.
  • 50 / 60 Hz rated frequency.
  • 440 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • Thermal-magnetic protection against overload and short-circuit conditions.
  • Compact DIN-rail construction for modular electrical distribution equipment.

Reliable Two-Pole Circuit Protection

Miniature circuit breakers such as the ABB SH202M-C2 automatically disconnect a circuit when excessive current results from an overload or short circuit. Thermal operation responds to sustained overload conditions, while magnetic operation provides rapid disconnection when severe short-circuit currents occur.

The Type C characteristic makes the SH202M-C2 suitable for many circuits where moderate inrush current occurs during normal equipment start-up. Its two-pole construction provides coordinated switching and protection, while the 10 kA breaking capacity supports dependable protection in appropriately designed electrical installations.

Typical Applications

  • Residential electrical distribution boards.
  • Commercial electrical distribution systems.
  • Industrial electrical control panels.
  • Low-current control and auxiliary circuits.
  • Circuits requiring simultaneous two-pole disconnection.
  • Equipment circuits with moderate normal starting currents.

Technical Specifications

Series SH200M
ABB order code 2CDS272011R0024
Product type Miniature circuit breaker (MCB)
Number of poles 2
Number of protected poles 2
Rated current 2 A
Tripping characteristic Type C
Rated short-circuit breaking capacity 10 kA
Rated operational voltage 400 V AC
Rated insulation voltage 440 V
Rated impulse withstand voltage 4 kV
Rated frequency 50 / 60 Hz
Standard IEC/EN 60898-1
Protection principle Thermal-magnetic
Mounting type DIN rail
Number of modules 2
Width 35 mm

Frequently Asked Questions

What is the ABB SH202M-C2 used for?

The ABB SH202M-C2 is a two-pole miniature circuit breaker used to protect electrical circuits against overloads and short circuits while providing simultaneous switching of two conductors.

What is the rated current of the SH202M-C2?

The SH202M-C2 has a rated current of 2 A.

What does the Type C characteristic mean?

The Type C tripping characteristic is suitable for circuits where moderate starting or inrush currents can occur during normal operation, helping accommodate normal equipment start-up while maintaining effective fault protection.

What is the breaking capacity of the ABB SH202M-C2?

The SH202M-C2 has a 10 kA short-circuit breaking capacity.

How many poles does the SH202M-C2 have?

The SH202M-C2 is a two-pole (2P) miniature circuit breaker, allowing two conductors to be switched and protected together.

Trusted ABB Circuit Protection

ABB SH200M miniature circuit breakers provide dependable thermal-magnetic protection in a compact DIN-rail format, helping protect electrical distribution and control circuits against overload and short-circuit conditions.