Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB S201MTR-C40 DC is a 40 A single-pole Type C miniature circuit breaker with 10 kA DC ultimate short-circuit breaking capacity, designed for overload and short-circuit protection in rolling stock and traction DC circuits.
£114.23
The ABB S201MTR-C40 DC is a high-performance single-pole miniature circuit breaker (MCB) designed for the protection and control of DC circuits against overloads and short circuits. Part of ABB's specialised S 200 MTR DC series for rolling stock and traction applications, this breaker combines a 40 A rated current with Type C tripping characteristics and robust construction for demanding transportation electrical systems.
Developed specifically for DC railway applications, the S201MTR-C40 DC features ABB's ring-tongue connection and a polarity-dependent design as marked on the device. The S 200 MTR DC range provides high resistance to vibration, shock, humidity and demanding environmental conditions, making it suitable for electrical installations on rolling stock.
With a rated current of 40 A, single-pole configuration and 10 kA DC ultimate short-circuit breaking capacity, the S201MTR-C40 DC provides dependable protection for auxiliary, control and distribution circuits. ABB order code 2CDS271565R0404 identifies this exact Type C model.
Miniature circuit breakers such as the ABB S201MTR-C40 DC automatically interrupt an electrical circuit when excessive current results from an overload or short circuit. Its Type C characteristic provides effective protection while accommodating the moderate transient currents encountered in many control, auxiliary and distribution loads.
The S 200 MTR DC series has been engineered specifically for demanding rolling stock environments. Its dedicated DC design, secure ring-tongue connection, wide operating temperature range and railway-focused vibration, shock and fire-safety characteristics provide reliable protection for electrical systems installed in rail vehicles.
| Series | S 200 MTR DC |
|---|---|
| ABB order code | 2CDS271565R0404 |
| Product type | DC miniature circuit breaker |
| Product group | DC / Traction MCB |
| Rated current | 40 A |
| Number of poles | 1 |
| Tripping characteristic | Type C |
| Voltage type | DC |
| DC ultimate short-circuit breaking capacity | 10 kA |
| AC ultimate short-circuit breaking capacity | 15 kA |
| Standard | IEC/EN 60947-2 |
| Fire-safety classification | R26/HL3 according to EN 45545 |
| Vibration / shock classification | Category 1, Class A/B (body mounted) according to IEC 61373 |
| Connection type | Ring-tongue terminals |
| Polarity | Polarity dependent as marked on device |
| Operating temperature | -40 °C to +75 °C |
| Degree of protection | IP20; IP40 in enclosure with cover |
| Mounting | DIN rail TH35-7.5 / TH35-15 |
| Modular width | 1 module |
| Dimensions (H × W × D) | 85 × 17.5 × 69 mm |
| Weight | 0.125 kg |
The S201MTR-C40 DC is designed to protect DC electrical circuits against overloads and short circuits, particularly in railway rolling stock and traction applications.
The breaker has a rated current of 40 A.
The S201MTR-C40 DC uses a Type C tripping characteristic, providing dependable circuit protection while accommodating moderate transient and inrush currents.
The S201MTR-C40 DC provides a 10 kA DC ultimate short-circuit breaking capacity according to IEC/EN 60947-2.
Yes. The S 200 MTR DC range is specifically designed for rolling stock applications and meets railway-focused requirements including R26/HL3 according to EN 45545 and Category 1, Class A/B according to IEC 61373.
ABB S 200 MTR DC miniature circuit breakers provide dedicated overload and short-circuit protection for demanding DC rolling stock installations, combining specialised railway construction with dependable electrical performance.
We use cookies
We use essential cookies to run this site, your basket and checkout. With your permission we'd also like to use analytics and advertising cookies to understand how the site is used and to measure our adverts.