2CDS211103R0104 ABB SH201-C10NA 10 A Type C 1P+N 6 kA Miniature Circuit Breaker

2CDS211103R0104 ABB SH201-C10NA 10 A Type C 1P+N 6 kA Miniature Circuit Breaker

ABB SH201-C10NA is a 10 A Type C 1P+N miniature circuit breaker with 6 kA breaking capacity for overload and short-circuit protection with neutral switching in electrical circuits.

SKU: 2CDS211103R0104Alt SKU: SH201C10NAMPN: 2CDS211103R0104
Price
List Price £41.03 ex VAT
Your Price (ex VAT) Save 25%
£30.77 25% OFF
You save £10.26 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £30.77
Trade pricing is personalised to your account

Manufacturer Lead Time

£30.77

Why Choose the ABB SH201-C10NA Miniature Circuit Breaker?

The ABB SH201-C10NA is a compact and reliable 1P+N miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits while also switching the neutral conductor. As part of the ABB SH200 series, it provides thermal-magnetic circuit protection in a modular DIN-rail format for residential, commercial and electrical distribution applications.

Featuring a 10 A rated current, Type C tripping characteristic and 6 kA rated short-circuit breaking capacity, the SH201-C10NA is suitable for circuits where moderate short-duration starting or inrush currents may occur. The Type C characteristic provides tolerance of these transient currents while maintaining dependable overload and short-circuit protection.

The SH201-C10NA combines a protected phase pole and switched neutral in a 1P+N configuration. This makes it a practical choice for final, auxiliary and control circuits where phase protection and simultaneous neutral switching are required within a compact DIN-rail installation.

Key Advantages

  • Compact 1P+N miniature circuit breaker with phase protection and neutral switching.
  • 10 A rated current for dependable circuit protection.
  • Type C tripping characteristic suited to circuits with moderate starting or inrush currents.
  • 6 kA rated short-circuit breaking capacity.
  • Provides combined overload and short-circuit protection.
  • Switched neutral supports simultaneous phase and neutral disconnection.
  • DIN-rail format enables straightforward integration into modular distribution and control equipment.

Key Features

  • ABB SH200 series.
  • 1P+N configuration with one protected phase pole and switched neutral.
  • 10 A rated current.
  • Type C tripping characteristic.
  • 6 kA rated short-circuit breaking capacity.
  • Thermal protection against sustained overload currents.
  • Magnetic protection against short-circuit fault currents.
  • Suitable for appropriately designed circuits with moderate short-duration inrush currents.
  • Compact modular construction for DIN-rail installation.

Reliable Protection for Final and Control Circuits

Miniature circuit breakers such as the ABB SH201-C10NA automatically disconnect a circuit when excessive current occurs because of an overload or short circuit. The thermal element responds to sustained overload conditions, while the magnetic mechanism provides rapid disconnection during sufficiently high short-circuit fault currents.

The Type C characteristic provides tolerance of moderate short-duration inrush currents, making the SH201-C10NA suitable for appropriately designed circuits supplying lighting, control equipment and other loads that can draw increased current during energisation. Its 1P+N configuration additionally switches the neutral conductor when the breaker is operated.

Typical Applications

  • Lighting circuits with moderate inrush currents.
  • Control and auxiliary electrical circuits.
  • Building automation equipment.
  • General-purpose final circuits where a 10 A Type C breaker is appropriate.
  • Residential and commercial electrical distribution.
  • DIN-rail control panels and electrical enclosures.

Technical Specifications

Series SH200
ABB order code 2CDS211103R0104
Product type Miniature circuit breaker (MCB)
Number of poles 1P+N
Protected poles 1
Neutral switching Yes
Rated current 10 A
Tripping characteristic Type C
Rated frequency 50/60 Hz
Rated short-circuit capacity (Icn) 6 kA
Rated insulation voltage (Ui) 500 V
Rated impulse withstand voltage (Uimp) 4 kV
Energy limiting class 3
Overvoltage category III
Pollution degree 2
Operating temperature -25 to +55 °C
Mounting type DIN-rail mounting
Standard IEC/EN 60898-1

Frequently Asked Questions

What is the ABB SH201-C10NA used for?

The ABB SH201-C10NA is used to protect 10 A electrical circuits against overloads and short circuits while also switching the neutral conductor.

What is the current rating of the SH201-C10NA?

The SH201-C10NA has a rated current of 10 A.

What does the Type C characteristic mean?

The Type C tripping characteristic provides tolerance of moderate short-duration starting and inrush currents, making it suitable for appropriately designed circuits containing loads with moderate energisation currents.

What is the breaking capacity of the ABB SH201-C10NA?

The SH201-C10NA has a rated short-circuit breaking capacity of 6 kA.

What does the 1P+N configuration provide?

The 1P+N configuration provides overcurrent protection for the phase conductor together with switching of the neutral conductor, supporting simultaneous phase and neutral disconnection.

Trusted Circuit Protection from ABB

ABB SH200 miniature circuit breakers provide dependable thermal-magnetic protection in a compact modular format, supporting safe and efficient circuit protection across residential, commercial and electrical distribution applications.