2CDS211103R0065 ABB SH201-B6NA Miniature Circuit Breaker 1P+N Type B 6 A 6 kA

2CDS211103R0065 ABB SH201-B6NA Miniature Circuit Breaker 1P+N Type B 6 A 6 kA

ABB SH201-B6NA miniature circuit breaker, a 6 A 1P+N Type B MCB with a 6 kA short-circuit capacity, overcurrent protection for the phase conductor and simultaneous neutral switching.

SKU: 2CDS211103R0065Alt SKU: SH201B6NAMPN: 2CDS211103R0065
Price
List Price £77.51 ex VAT
Your Price (ex VAT) Save 25%
£58.13 25% OFF
You save £19.38 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £58.13
Trade pricing is personalised to your account

Manufacturer Lead Time

£58.13

Why Choose the ABB SH201-B6NA Miniature Circuit Breaker?

The ABB SH201-B6NA is a compact 1P+N miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits while providing simultaneous switching of the neutral conductor. Part of the ABB Compact Home SH200 range, it combines thermal overload protection with electromagnetic short-circuit protection in a practical DIN-rail format.

Featuring a Type B tripping characteristic, the SH201-B6NA is suited to circuits with relatively low normal inrush currents, including appropriately designed lighting, resistive, control and general-purpose loads. Its 6 A rated current makes it suitable for low-current final circuits where phase protection and neutral switching are required.

With a rated short-circuit capacity of 6 kA, the SH201-B6NA provides dependable circuit protection for residential and similar electrical installations. ABB order code 2CDS211103R0065 identifies this specific 6 A Type B phase-and-neutral model.

Key Advantages

  • Provides overload and short-circuit protection for the phase conductor.
  • 1P+N configuration combines a protected phase pole with simultaneous neutral switching.
  • 6 A rated current for appropriately designed low-current final circuits.
  • Type B tripping characteristic suits circuits with relatively low normal inrush currents.
  • 6 kA rated short-circuit capacity for dependable fault protection.
  • DIN-rail construction supports straightforward installation in compatible distribution equipment.

Key Features

  • ABB Compact Home SH200 series.
  • 6 A rated current.
  • 1P+N configuration.
  • One overcurrent-protected phase pole plus switched neutral.
  • Type B tripping characteristic.
  • Thermal tripping mechanism for overload protection.
  • Electromagnetic tripping mechanism for short-circuit protection.
  • 6 kA rated short-circuit capacity.
  • Phase and neutral conductors are disconnected together when the device operates.
  • DIN-rail mounting for use in compatible consumer units and distribution boards.

Compact Phase and Neutral Circuit Protection

The ABB SH201-B6NA combines overcurrent protection of the phase conductor with switching of the neutral conductor. Its thermal mechanism responds to sustained overloads, while its electromagnetic mechanism provides rapid operation under short-circuit conditions. The linked neutral pole is switched with the protected phase pole, allowing both conductors to be disconnected together.

The Type B characteristic is appropriate for circuits with relatively low normal starting currents. Combined with a 6 A rating, 1P+N configuration and 6 kA short-circuit capacity, the SH201-B6NA provides a practical protection solution for suitably designed residential and similar final circuits requiring neutral switching.

Typical Applications

  • Residential electrical installations.
  • Low-current lighting circuits.
  • Control and auxiliary circuits.
  • Resistive and general-purpose loads with relatively low normal inrush currents.
  • Final circuits requiring simultaneous phase and neutral disconnection.
  • Consumer units and distribution boards using compatible DIN-rail devices.
  • Applications specifically requiring a 6 A Type B 1P+N miniature circuit breaker.

Technical Specifications

Series Compact Home SH200
Product group SH200 MCB
ABB order code 2CDS211103R0065
Product type Miniature circuit breaker (MCB)
Pole configuration 1P+N
Protected poles 1
Neutral Switched, non-overcurrent-protected
Rated current 6 A
Tripping characteristic Type B
Rated short-circuit capacity 6 kA
Protection principle Thermal-magnetic
Mounting type DIN rail

Frequently Asked Questions

What is the ABB SH201-B6NA used for?

The ABB SH201-B6NA is a 1P+N miniature circuit breaker used to protect suitably rated electrical circuits against overloads and short circuits while also switching the neutral conductor.

What is the current rating of the SH201-B6NA?

The SH201-B6NA has a rated current of 6 A.

What does the Type B characteristic mean?

The Type B tripping characteristic is suited to circuits with relatively low normal starting or inrush currents, including appropriately designed lighting, resistive, control and general-purpose loads.

What is the short-circuit capacity of the ABB SH201-B6NA?

The SH201-B6NA has a rated short-circuit capacity of 6 kA.

What does 1P+N mean on the ABB SH201-B6NA?

1P+N means the device has one overcurrent-protected phase pole together with a switched neutral pole. The neutral is not independently protected against overcurrent, but it is switched with the phase so that both conductors are disconnected together when the breaker operates.

Trusted Circuit Protection from ABB

ABB Compact Home SH200 miniature circuit breakers provide dependable overload and short-circuit protection for residential and similar installations, with the SH201-B6NA combining a 6 A Type B characteristic with phase protection and simultaneous neutral switching.