2CDA381799R0101 ABB M301P-D10 MCB 25kA 1P D 10A Magnetic

2CDA381799R0101 ABB M301P-D10 MCB 25kA 1P D 10A Magnetic

ABB M301P-D10 is a single-pole 10 A magnetic-only miniature circuit breaker with a 140 A instantaneous trip current and 25 kA ultimate short-circuit breaking capacity at 240 V AC for industrial short-circuit protection applications.

SKU: 2CDA381799R0101Alt SKU: M301PD10MPN: 2CDA381799R0101
Price
List Price £43.31 ex VAT
Your Price (ex VAT) Save 45%
£23.82 45% OFF
You save £19.49 per unit
Manufacturer Lead Time Estimated Delivery 14 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £23.82
Trade pricing is personalised to your account

Manufacturer Lead Time

£23.82

Why Choose the ABB M301P-D10 Magnetic-Only Miniature Circuit Breaker?

The ABB M301P-D10 is a high-performance single-pole magnetic-only miniature circuit breaker (MCB) designed specifically for short-circuit protection in industrial electrical applications. As part of ABB's M300P / S300P circuit protection range, it combines a 10 A rated current with magnetic instantaneous operation for applications where overload protection is provided separately.

The M301P-D10 offers a 25 kA ultimate short-circuit breaking capacity (Icu) at 240 V AC, making it suitable for industrial circuits with high prospective fault currents. Unlike conventional thermal-magnetic MCBs, this model provides magnetic-only short-circuit protection; a separate device is therefore required where protection against sustained overloads is necessary.

With its single-pole configuration, compact modular construction and DIN-rail mounting, the M301P-D10 integrates efficiently into industrial distribution and control panels. Its instantaneous magnetic trip current is 140 A, allowing it to accommodate substantial transient currents while providing rapid operation under short-circuit conditions.

Key Advantages

  • Dedicated magnetic-only short-circuit protection for industrial electrical circuits.
  • 10 A rated current with a 140 A instantaneous magnetic trip current.
  • Single-pole (1P) configuration for compact circuit protection.
  • 25 kA ultimate short-circuit breaking capacity (Icu) at 240 V AC.
  • Designed for applications where overload protection is provided by a separate protective device.
  • Compact modular construction for straightforward DIN-rail installation.

Key Features

  • ABB M300P / S300P magnetic-only MCB range.
  • 10 A rated current.
  • Single protected pole (1P).
  • Magnetic-only tripping mechanism.
  • 140 A rated instantaneous trip current.
  • 25 kA Icu at 240 V AC.
  • 12.5 kA Ics at 240 V AC.
  • Designed for industrial short-circuit protection.
  • DIN-rail mounting for modular distribution and control panels.
  • ABB order code 2CDA381799R0101.

High-Capacity Magnetic Protection for Industrial Circuits

The ABB M301P-D10 differs from a conventional thermal-magnetic MCB because its primary function is magnetic short-circuit protection. When current rises rapidly to the magnetic operating threshold during a short circuit, the breaker trips quickly to disconnect the affected circuit. For complete protection against both short circuits and sustained overloads, an appropriately selected separate overload protection device is required.

Its combination of a 10 A rated current, 140 A instantaneous trip current and 25 kA Icu at 240 V AC makes the M301P-D10 suitable for industrial applications where high fault-current capability and tolerance of normal transient currents are important. The modular single-pole format also makes it practical for integration into machinery, automation and industrial distribution panels.

Typical Applications

  • Industrial machinery and automation systems.
  • Industrial electrical distribution panels.
  • Control and auxiliary circuits requiring magnetic-only protection.
  • Circuits where separate overload protection is already provided.
  • Equipment circuits with substantial transient or starting currents.
  • Industrial applications requiring high short-circuit breaking capacity.

Technical Specifications

Series M300P / S300P
Order code 2CDA381799R0101
EAN 4016779089203
Product type Magnetic-only miniature circuit breaker (MCB)
Rated current 10 A
Number of poles 1
Number of protected poles 1
Trip characteristic D / magnetic-only
Instantaneous trip current 140 A
Ultimate short-circuit breaking capacity (Icu) 25 kA at 240 V AC
Service short-circuit breaking capacity (Ics) 12.5 kA at 240 V AC
DC ultimate short-circuit breaking capacity (Icu) 25 kA at 72 V DC
Rated insulation voltage (Ui) 500 V
Rated impulse withstand voltage (Uimp) 6 kV
Frequency 50 / 60 Hz and DC
Protection function Short-circuit protection
Trip mechanism Magnetic only
Standard IEC/EN 60947-2
Degree of protection IP20
Operating temperature -40 to +70 °C
Terminal type Screw terminal
Tightening torque 2.8 N·m
Mounting type DIN rail
Number of modules 1
Dimensions (H × W × D) approx. 88 × 17.5 × 66.7 mm
Weight approx. 0.124 kg

Frequently Asked Questions

What is the ABB M301P-D10 used for?

The ABB M301P-D10 is a magnetic-only miniature circuit breaker designed primarily to protect industrial electrical circuits against short circuits. Where overload protection is required, it must be provided by a suitable separate protective device.

What is the rated current of the M301P-D10?

The M301P-D10 has a rated current of 10 A and a rated instantaneous magnetic trip current of 140 A.

How many poles does the ABB M301P-D10 have?

The M301P-D10 is a single-pole (1P) magnetic-only miniature circuit breaker with one protected pole.

Does the ABB M301P-D10 provide overload protection?

No. The M301P-D10 uses magnetic-only operation for short-circuit protection. A separate protective device is required where protection against sustained overload currents is necessary.

What is the breaking capacity of the ABB M301P-D10?

The ABB M301P-D10 has an ultimate short-circuit breaking capacity (Icu) of 25 kA at 240 V AC and a service short-circuit breaking capacity (Ics) of 12.5 kA at 240 V AC.

Trusted ABB Industrial Circuit Protection

ABB modular circuit protection products provide dependable solutions for demanding industrial installations, with the M301P-D10 combining magnetic-only operation, a 10 A rating, 140 A instantaneous trip current and 25 kA ultimate short-circuit breaking capacity for specialised short-circuit protection applications.