2CCS891001R0081 ABB S801N-D8 8 A 1-Pole Type D High Performance MCB 36 kA

2CCS891001R0081 ABB S801N-D8 8 A 1-Pole Type D High Performance MCB 36 kA

ABB S801N-D8 is an 8 A single-pole Type D high-performance miniature circuit breaker with a 36 kA breaking capacity for reliable overload and short-circuit protection.

SKU: 2CCS891001R0081Alt SKU: S801ND8MPN: 2CCS891001R0081
Price
List Price £95.72 ex VAT
Your Price (ex VAT) Save 35%
£62.22 35% OFF
You save £33.50 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £62.22
Trade pricing is personalised to your account

Manufacturer Lead Time

£62.22

Why Choose the ABB S801N-D8 High Performance MCB?

The ABB S801N-D8 is a high-performance 1-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in demanding electrical distribution and industrial control systems. As part of the ABB S800N high-performance circuit breaker series, it combines high fault-current interruption capability with a compact modular design for commercial and industrial applications.

This current-limiting circuit breaker features a Type D tripping characteristic and a rated current of 8 A. Its thermal tripping mechanism provides protection against sustained overloads, while the electromagnetic mechanism responds rapidly to short-circuit faults. The D characteristic is particularly suitable for circuits supplying equipment with relatively high starting or inrush currents.

With a breaking capacity of 36 kA, the S801N-D8 is designed for installations where substantial prospective fault currents can occur. Its single-pole configuration makes it suitable for individual conductor protection, while the S800 series' current-limiting design and fast arc-extinction technology support dependable fault interruption.

Key Advantages

  • High-performance 1-pole miniature circuit breaker for demanding electrical installations.
  • 8 A rated current for reliable circuit protection.
  • Type D tripping characteristic suitable for loads with high starting or inrush currents.
  • High 36 kA breaking capacity for installations with substantial prospective fault currents.
  • Thermal overload and electromagnetic short-circuit protection.
  • Current-limiting design with fast arc extinction for dependable fault interruption.

Key Features

  • ABB S800N high-performance MCB series.
  • 1-pole configuration.
  • 8 A rated current.
  • Type D tripping characteristic.
  • 36 kA breaking capacity.
  • Thermal and electromagnetic trip mechanisms.
  • Fast current-limiting operation and arc extinction.
  • Modular construction for integration into electrical distribution and industrial control systems.

High-Performance Circuit Protection

The ABB S800N range is engineered for installations requiring compact circuit protection combined with high short-circuit interruption capability. Its thermal trip responds to sustained overload conditions, while the electromagnetic trip provides rapid interruption when severe short-circuit currents occur.

The S801N-D8 combines an 8 A rating with a Type D trip curve, making it particularly useful for circuits supplying equipment with elevated starting currents. Current-limiting operation helps reduce the energy passed through during a fault, supporting the protection of conductors and downstream electrical equipment.

Typical Applications

  • Industrial machinery and control circuits.
  • Motor and transformer circuits with elevated starting currents.
  • Industrial control panels and switchboards.
  • Commercial electrical distribution systems.
  • Automation and production equipment.
  • Circuits requiring high short-circuit interruption capability.

Technical Specifications

Series S800N
ABB order code 2CCS891001R0081
Product type High-performance miniature circuit breaker (MCB)
Number of poles 1
Rated current 8 A
Tripping characteristic Type D
Breaking capacity 36 kA
Protection function Overload and short-circuit protection
Trip technology Thermal and electromagnetic
Mounting Modular rail mounting

Frequently Asked Questions

What is the ABB S801N-D8 used for?

The S801N-D8 is used to protect electrical circuits against overloads and short circuits, particularly in demanding commercial and industrial applications.

What is the current rating of the S801N-D8?

The ABB S801N-D8 has a rated current of 8 A.

What tripping characteristic does the S801N-D8 use?

The S801N-D8 uses a Type D tripping characteristic, making it suitable for loads that can produce relatively high starting or inrush currents.

What is the breaking capacity of the ABB S801N-D8?

The S801N-D8 has a high breaking capacity of 36 kA, making it suitable for installations where substantial prospective short-circuit currents may occur.

How many poles does the S801N-D8 have?

The S801N-D8 is a 1-pole circuit breaker designed to provide overload and short-circuit protection for a single protected conductor.

Trusted High-Performance Protection from ABB

ABB S800N high-performance miniature circuit breakers provide dependable overload and short-circuit protection for demanding electrical distribution and industrial applications, combining high interruption capability, current limitation and robust modular construction.