ABB S802C-K50 is a 50 A two-pole Type K high-performance miniature circuit breaker with a 25 kA ultimate short-circuit breaking capacity at 415 V AC for demanding commercial and industrial circuit protection.
£98.86
The ABB S802C-K50 is a high-performance two-pole miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits. Part of the ABB S800C high-performance circuit breaker series, it combines high breaking capacity with current-limiting performance for demanding commercial and industrial electrical installations.
This MCB features a Type K tripping characteristic, making it particularly suitable for circuits supplying motors, transformers and other equipment with elevated starting or inrush currents. Thermal overload protection is combined with electromagnetic short-circuit protection to provide dependable circuit protection while accommodating appropriate equipment start-up currents.
With a rated current of 50 A, a two-pole configuration and a rated ultimate short-circuit breaking capacity of 25 kA at 415 V AC, the S802C-K50 provides robust protection where substantial prospective fault currents may occur. Its modular construction and cage terminals support integration into industrial switchgear, machinery and electrical distribution assemblies.
Miniature circuit breakers such as the ABB S802C-K50 automatically disconnect electrical circuits when excessive current occurs because of an overload or short circuit. The S800C series combines thermal overload protection with electromagnetic short-circuit protection and current-limiting operation, helping protect conductors and connected equipment while reducing the energy passed through during severe fault conditions.
The Type K characteristic makes the S802C-K50 particularly suitable for circuits supplying equipment that can draw elevated current during normal start-up. Combined with its 50 A current rating, two-pole construction and 25 kA ultimate breaking capacity at 415 V AC, it provides a high-performance protection solution for motors, transformers, industrial machinery and electrical distribution systems.
Tick the specs you need, then view products that match.
| Certification | UL 1077 | |
|---|---|---|
| Series | S800C | |
| ABB order code | 2CCS882001R0577 | |
| EAN | 7612271213336 | |
| Product group | S800 / S800P / S750 MCB | |
| Product type | High-performance miniature circuit breaker (MCB) | |
| Number of poles | 2 | |
| Number of protected poles | 2 | |
| Rated current | 50 A | |
| Tripping characteristic | Type K | |
| Rated operational voltage | 400 V AC according to IEC 60898-1; 415 V AC according to IEC 60947-2 | |
| Rated ultimate short-circuit breaking capacity (Icu) | 25 kA at 415 V AC | |
| Rated service short-circuit breaking capacity (Ics) | 25 kA at 415 V AC | |
| Rated short-circuit breaking capacity (Icn) | 15 kA at 400 V AC according to EN 60898 | |
| Rated insulation voltage (Ui) | 500 V | |
| Rated impulse withstand voltage (Uimp) | 8 kV | |
| Voltage type | AC/DC | |
| Frequency | 50 Hz | |
| Contact position indication | ON / OFF / TRIP | |
| Energy limiting class | 3 | |
| Terminal type | Cage screw terminals | |
| Flexible conductor capacity | up to 50 mm² | |
| Rigid conductor capacity | up to 70 mm² | |
| Tightening torque | 3.5 N·m | |
| Built-in depth | 82.5 mm | |
| Standards | IEC/EN 60947-2, IEC/EN 60898-1, UL 1077 | |
| Weight | approx. 0.49 kg |
The ABB S802C-K50 provides overload and short-circuit protection for two-pole electrical circuits in commercial and industrial installations, particularly circuits supplying motors, transformers and other equipment with elevated starting currents.
The S802C-K50 has a rated current of 50 A and uses a two-pole configuration with both poles protected.
The Type K tripping characteristic is suited to circuits supplying equipment with elevated starting or inrush currents, including motors, transformers and appropriate industrial machinery.
The S802C-K50 has a rated ultimate short-circuit breaking capacity of 25 kA at 415 V AC according to IEC 60947-2, providing high-performance protection where substantial prospective fault currents may occur.
The S802C-K50 is specified to IEC/EN 60947-2 and IEC/EN 60898-1 and is also listed to UL 1077.
ABB S800C high-performance miniature circuit breakers provide dependable overload and short-circuit protection for demanding commercial and industrial electrical installations, combining high breaking capacity, current-limiting operation and robust modular construction.