ABB S803U-K60 is a 60 A three-pole high-performance miniature circuit breaker with K tripping characteristic, 50 kA short-circuit breaking capacity and UL 489 compliance for demanding electrical circuit protection.

SKU: 2CCS863017R0587Alt SKU: S803UK60MPN: 2CCS863017R0587
Price
List Price £361.10 ex VAT
Your Price (ex VAT) Save 35%
£234.72 35% OFF
You save £126.39 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £234.72
Trade pricing is personalised to your account

Manufacturer Lead Time

£234.72

Why Choose the ABB S803U-K60 High-Performance MCB?

The ABB S803U-K60 is a high-performance three-pole miniature circuit breaker (MCB) designed to provide dependable overload and short-circuit protection in demanding electrical distribution systems. As part of the ABB S800U circuit breaker range, it combines a rated current of 60 A, K tripping characteristic and high short-circuit performance for industrial machinery, control and power-distribution applications.

The S803U-K60 uses thermal and electromagnetic tripping mechanisms to protect conductors and connected equipment against sustained overloads and short-circuit faults. Its current-limiting design rapidly interrupts high fault currents, helping reduce thermal and electrodynamic stresses on downstream components while providing reliable protection in installations with high prospective fault levels.

With a three-pole configuration, 60 A rated current and K characteristic, the S803U-K60 is suited to appropriately rated circuits containing motors, transformers and other inductive loads with elevated starting currents. Its 50 kA short-circuit breaking capacity and UL 489 compliance make it a robust protective solution for demanding electrical installations.

Key Advantages

  • High-performance three-pole miniature circuit breaker for demanding electrical installations.
  • 60 A rated current for appropriately rated machinery, control and distribution circuits.
  • K tripping characteristic suited to loads with elevated starting or inrush currents.
  • High 50 kA short-circuit breaking capacity for installations with substantial prospective fault currents.
  • UL 489 compliance for branch-circuit protection applications within applicable ratings.
  • Thermal and electromagnetic tripping provides overload and short-circuit protection.
  • Current-limiting technology helps reduce fault energy and stresses on connected equipment.
  • Compact modular construction supports integration into professional electrical distribution assemblies.

Key Features

  • ABB S800U high-performance MCB range.
  • 3-pole configuration.
  • 60 A rated current.
  • K tripping characteristic.
  • 50 kA short-circuit breaking capacity.
  • UL 489 compliant.
  • Thermal overload and electromagnetic short-circuit tripping.
  • Current-limiting circuit protection technology.
  • Suitable for appropriately rated motor, transformer and inductive-load circuits.
  • DIN rail mounting for integration into electrical distribution assemblies.

High-Performance UL 489 Circuit Protection

The ABB S800U range provides high-performance circuit protection for applications requiring dependable interruption of overload and short-circuit currents. The S803U-K60 automatically disconnects the protected circuit when fault conditions occur, helping safeguard conductors, machinery and downstream electrical equipment.

Its K characteristic provides tolerance of temporary starting currents while retaining effective protection for appropriately rated circuits. This makes the S803U-K60 particularly useful for motors, transformers and other inductive equipment where elevated inrush currents can occur during normal starting or energisation.

Typical Applications

  • Industrial electrical distribution systems.
  • Three-phase machinery and equipment circuits.
  • Motor and inductive-load circuits within appropriate ratings.
  • Transformer and equipment protection.
  • Control panels and switchgear assemblies.
  • Industrial automation and manufacturing equipment.
  • UL 489 branch-circuit protection applications.
  • High fault-level installations requiring high-performance circuit protection.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Series S800U
ABB order code 2CCS863017R0587
Product type High-performance miniature circuit breaker (MCB)
Number of poles 3
Rated current 60 A
Tripping characteristic K
Short-circuit breaking capacity 50 kA
Protection function Overload and short-circuit protection
Tripping mechanisms Thermal and electromagnetic
Standard UL 489
Mounting type DIN rail

Frequently Asked Questions

What is the ABB S803U-K60 used for?

The ABB S803U-K60 is a high-performance three-pole miniature circuit breaker used to protect appropriately rated electrical circuits against overloads and short circuits, including suitable machinery, motor and inductive-load applications.

What is the rated current of the S803U-K60?

The S803U-K60 has a rated current of 60 A.

What tripping characteristic does the S803U-K60 use?

The breaker uses a K tripping characteristic, making it suitable for appropriately rated circuits containing motors, transformers and other loads that can experience elevated temporary starting currents.

What is the breaking capacity of the ABB S803U-K60?

The S803U-K60 has a short-circuit breaking capacity of 50 kA, providing high fault-current interruption capability for demanding electrical installations.

Which standard does the ABB S803U-K60 comply with?

The S803U-K60 is designed for compliance with UL 489 for applicable branch-circuit protection applications.

Trusted ABB Circuit Protection

ABB S800 high-performance circuit breakers are designed for demanding electrical distribution applications, combining high short-circuit performance, current-limiting technology and dependable overload and short-circuit protection in a compact modular format.