2CCS862017R0577 ABB S802U-K50 50 A 2-Pole Type K 50 kA UL 489 MCB

2CCS862017R0577 ABB S802U-K50 50 A 2-Pole Type K 50 kA UL 489 MCB

ABB S802U-K50 is a 50 A two-pole Type K high-performance miniature circuit breaker with 50 kA breaking capacity at 240 V AC and UL 489 compliance for demanding industrial circuit protection.

SKU: 2CCS862017R0577Alt SKU: S802UK50MPN: 2CCS862017R0577
Price
List Price £255.00 ex VAT
Your Price (ex VAT) Save 35%
£165.75 35% OFF
You save £89.25 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £165.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£165.75

Why Choose the ABB S802U-K50 High-Performance MCB?

The ABB S802U-K50 is a robust two-pole high-performance miniature circuit breaker (MCB) designed to protect electrical circuits against overloads and short circuits in demanding industrial applications. Part of the ABB S800U high-performance circuit breaker series, it combines a 50 A rated current with a powerful 50 kA short-circuit breaking capacity and compliance with UL 489.

Featuring a Type K tripping characteristic, the S802U-K50 is particularly suitable for circuits containing equipment with elevated starting or inrush currents. Its thermal release provides effective overload protection, while the electromechanical release responds rapidly to short-circuit conditions, helping provide dependable protection for cables, conductors and connected equipment.

With a two-pole configuration, 50 A rated current and 240 V AC operational voltage, the S802U-K50 is engineered for industrial distribution and equipment applications requiring high fault-current interruption capability. Its S800U design and UL 489 certification also make it suitable for installations where recognised North American circuit-breaker standards are required.

Key Advantages

  • High-performance two-pole miniature circuit breaker for industrial circuit protection.
  • 50 A rated current for demanding electrical loads.
  • High 50 kA short-circuit breaking capacity at 240 V AC.
  • Type K tripping characteristic suited to equipment with elevated starting and inrush currents.
  • UL 489 compliant for applications requiring recognised North American circuit-breaker standards.
  • Thermal and electromechanical releases provide effective overload and short-circuit protection.

Key Features

  • ABB S800U high-performance circuit breaker series.
  • 50 A rated current.
  • 2-pole configuration.
  • Type K tripping characteristic.
  • 50 kA breaking capacity at 240 V AC.
  • Compliant with UL 489 and IEC/EN 60947-2.
  • Thermal overload and electromechanical short-circuit protection.
  • Contact position indication for ON / OFF / TRIP status.

High-Performance UL 489 Circuit Protection

High-performance circuit breakers such as the ABB S802U-K50 automatically disconnect electrical circuits when excessive current occurs. Its thermal release responds to sustained overload conditions, while its electromechanical short-circuit release provides rapid interruption when severe fault currents occur.

The S800U range is designed for industrial applications requiring high short-circuit interruption capability and compliance with international standards. The Type K characteristic makes the S802U-K50 particularly useful where normal equipment operation can produce elevated starting currents, while its 50 kA interruption capability provides robust protection in installations with substantial prospective fault currents.

Typical Applications

  • Industrial electrical distribution systems.
  • Machinery and production equipment.
  • Motor and transformer-related circuits with elevated starting currents.
  • Industrial control and power panels.
  • Electrical installations requiring UL 489 circuit breakers.
  • Distribution systems requiring high short-circuit breaking capacity.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 489
Series S800U
ABB order code 2CCS862017R0577
Product type High-performance miniature circuit breaker (MCB)
Rated current 50 A
Number of poles 2
Number of protected poles 2
Tripping characteristic Type K
Rated operational voltage 240 V AC
Rated voltage 240 / 415 V AC
Short-circuit breaking capacity 50 kA at 240 V AC
Standards IEC/EN 60947-2, UL 489
Protection rating IP20
Power loss 4.3 W
Terminal type Screw
Contact position indication ON / OFF / TRIP
Operating temperature -25 to +60 °C
Storage temperature -40 to +70 °C
Dimensions (H × W × D) 95 × 54 × 82.5 mm
Weight approx. 0.49 kg

Frequently Asked Questions

What is the ABB S802U-K50 used for?

The ABB S802U-K50 is used to protect industrial electrical circuits against overloads and short circuits, particularly where high breaking capacity and UL 489 compliance are required.

What is the rated current of the S802U-K50?

The circuit breaker has a rated current of 50 A.

What breaking capacity does the S802U-K50 provide?

The S802U-K50 provides a short-circuit breaking capacity of 50 kA at 240 V AC.

What does the Type K characteristic mean?

The Type K tripping characteristic is suited to circuits containing equipment that can experience elevated starting or inrush currents, helping reduce unwanted tripping while maintaining effective overload and short-circuit protection.

Is the ABB S802U-K50 UL 489 compliant?

Yes. The S802U-K50 complies with UL 489 and also meets IEC/EN 60947-2 requirements for industrial circuit breakers.

Trusted High-Performance Circuit Protection from ABB

ABB S800U high-performance circuit breakers provide dependable overload and short-circuit protection for demanding industrial electrical installations, combining high breaking capacity with UL 489 compliance and robust circuit protection technology.