ABB S802S-UCB63-R is a 63 A two-pole UC-B high-performance miniature circuit breaker with 50 kA Icu and Ics ratings at 500 V DC and ring tongue terminals for demanding commercial and industrial DC circuit protection.
£171.73
The ABB S802S-UCB63-R is a high-performance 2-pole miniature circuit breaker (MCB) designed specifically for demanding direct-current circuit protection. Part of the ABB S800S-UC range, it combines a 63 A rated current, UC-B tripping characteristic and high 50 kA short-circuit breaking capacity at 500 V DC.
The S802S-UCB63-R provides protection and control against overload and short-circuit conditions where high breaking capacity is required. Its UC-B characteristic is particularly suited to applications requiring sensitive magnetic tripping, including protection of people and long cable runs in TN and IT systems.
With a rated current of 63 A, a UC-B / Type B characteristic and both Icu and Ics ratings of 50 kA at 500 V DC, the S802S-UCB63-R provides robust two-pole protection for demanding DC systems. This version uses ring tongue terminals and is also suitable where selectivity with an upstream MCCB or back-up protection for downstream MCBs is required.
The ABB S802S-UCB63-R is engineered for protection and control of direct-current circuits against overload and short-circuit faults where high breaking capacity is required. Its 50 kA Icu and Ics ratings at 500 V DC provide substantial fault-clearing capability for demanding commercial and industrial DC distribution systems.
The UC-B characteristic supports sensitive circuit protection and is particularly useful for protection of people and long cable runs in TN and IT systems. The S802S-UCB63-R can also be applied where coordination with an upstream MCCB or back-up protection for downstream MCBs is required, while its ring tongue terminals provide secure electrical connections.
| Series | S800S-UC / S802S |
|---|---|
| ABB order code | 2CCS862002R1635 |
| Product type | High-performance miniature circuit breaker (MCB) |
| Number of poles | 2 |
| Number of protected poles | 2 |
| Rated current | 63 A |
| Tripping characteristic | UC-B / Type B |
| Rated operational voltage | 500 V DC |
| Rated ultimate short-circuit breaking capacity (Icu) | 50 kA at 500 V DC |
| Rated service short-circuit breaking capacity (Ics) | 50 kA at 500 V DC |
| Voltage type | DC |
| Power loss | 12.4 W |
| Degree of protection | IP20 |
| Operating ambient temperature | -25 to +60 °C |
| Storage ambient temperature | -40 to +70 °C |
| Contact-position indication | ON / OFF / TRIP |
| Terminal version | Ring tongue terminal |
| Flexible conductor capacity | 1–50 mm² |
| Flexible stranded conductor capacity | 1–70 mm² |
| Standard | IEC/EN 60947-2 |
| Dimensions (W × H × D) | 54 × 142 × 82.5 mm |
| Weight | 0.49 kg |
| EAN | 7612271208509 |
| Product group | S800 / S800P / S750 MCB |
The ABB S802S-UCB63-R is a high-performance two-pole circuit breaker designed to protect demanding DC circuits against overload and short-circuit faults, including applications involving long cable runs and TN or IT systems.
The S802S-UCB63-R has a rated current of 63 A and uses ABB's UC-B / Type B tripping characteristic.
The S802S-UCB63-R has a rated ultimate short-circuit breaking capacity (Icu) of 50 kA at 500 V DC and a rated service short-circuit breaking capacity (Ics) of 50 kA at 500 V DC.
The UC-B characteristic is suited to DC applications requiring sensitive circuit protection, including protection of people and long cable runs in TN and IT systems, as well as installations requiring coordination with other protective devices.
The S802S-UCB63-R uses ring tongue terminals and supports flexible conductors from 1–50 mm² and flexible stranded conductors from 1–70 mm².
ABB S800S high-performance circuit breakers provide robust overload and short-circuit protection for demanding commercial and industrial systems, with the S800S-UC range engineered specifically for direct-current applications requiring high breaking capacity and dependable circuit protection.