2CCS861001R0201 ABB S801S-D20 20 A 1-Pole Type D 50 kA High Performance MCB

2CCS861001R0201 ABB S801S-D20 20 A 1-Pole Type D 50 kA High Performance MCB

ABB S801S-D20 is a 20 A 1-pole Type D high-performance miniature circuit breaker with a maximum ultimate short-circuit breaking capacity of 50 kA at 240/415 V AC for demanding commercial and industrial circuit protection.

SKU: 2CCS861001R0201Alt SKU: S801SD20MPN: 2CCS861001R0201
Price
List Price £88.24 ex VAT
Your Price (ex VAT) Save 35%
£57.36 35% OFF
You save £30.88 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £57.36
Trade pricing is personalised to your account

Manufacturer Lead Time

£57.36

Why Choose the ABB S801S-D20 High Performance MCB?

The ABB S801S-D20 is a high-performance miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection where high breaking capacity is required. As part of the ABB S800S high-performance circuit breaker series, it combines compact modular construction with strong current-limiting performance for commercial and industrial electrical distribution systems.

This circuit breaker features a Type D tripping characteristic, making it particularly suitable for circuits supplying equipment with comparatively high starting or inrush currents. It incorporates a thermal tripping mechanism for overload protection and an electromechanical tripping mechanism for short-circuit protection, while fast arc extinction helps limit fault energy and protect the installation.

With a rated current of 20 A, a 1-pole configuration and a maximum ultimate short-circuit breaking capacity of 50 kA at 240/415 V AC, the S801S-D20 is engineered for demanding protection applications. It can be used at voltages up to 400/690 V AC and is also suitable for DC applications, providing a versatile protection solution within ABB's S800 platform.

Key Advantages

  • High-performance miniature circuit breaker for overload and short-circuit protection.
  • 20 A rated current for commercial and industrial circuits.
  • Type D tripping characteristic suited to loads with high starting or inrush currents.
  • 1-pole configuration in a compact modular format.
  • Maximum ultimate short-circuit breaking capacity of 50 kA at 240/415 V AC.
  • Fast arc extinction and current-limiting operation help reduce electrical and thermal fault stresses.

Key Features

  • ABB S800S high-performance circuit breaker series.
  • 20 A rated current.
  • Type D characteristic.
  • 1-pole construction.
  • 50 kA maximum ultimate breaking capacity at 240/415 V AC.
  • 25 kA rated short-circuit capacity at 230/400 V AC.
  • Thermal tripping mechanism for overload protection.
  • Electromechanical tripping mechanism for short-circuit protection.
  • Cage terminal connection system.
  • Designed to IEC/EN 60947-2, IEC/EN 60898-1 and UL 1077 requirements.

Reliable High-Performance Circuit Protection

Miniature circuit breakers such as the ABB S801S-D20 automatically disconnect an electrical circuit when excessive current occurs. Its thermal tripping mechanism responds to sustained overload conditions, while its electromechanical tripping mechanism provides rapid short-circuit protection, helping safeguard conductors, connected equipment and electrical distribution systems.

The S800S series is engineered for installations where high prospective fault currents demand enhanced interruption capability. The S801S-D20 combines high current limitation with a Type D tripping characteristic, making it particularly useful for circuits supplying equipment that can produce substantial transient currents during energisation or starting.

Typical Applications

  • Industrial electrical distribution systems.
  • Machine and automation control panels.
  • Circuits supplying equipment with high starting currents.
  • Commercial electrical distribution boards.
  • Industrial machinery and production equipment.
  • Installations with high prospective short-circuit currents.

Technical Specifications

Tick the specs you need, then view products that match.

Certification UL 1077
Series S800S
ABB order code 2CCS861001R0201
Product type High-performance miniature circuit breaker
Rated current 20 A
Number of poles 1
Tripping characteristic Type D
Ultimate short-circuit breaking capacity 50 kA at 240/415 V AC
DC ultimate short-circuit breaking capacity 30 kA at 125 V DC
Rated short-circuit capacity 25 kA at 230/400 V AC
UL 1077 interrupting rating 30 kA at 240 V AC
Frequency 50 / 60 Hz
Power loss 3.5 W per pole at rated operating conditions
Terminal type Cage terminal
Mounting type DIN rail
Dimensions (H × W × D) approx. 95 × 27 × 82.5 mm
Weight approx. 0.24 kg
GTIN / EAN 7612271200992
Standards IEC/EN 60947-2, IEC/EN 60898-1, UL 1077
Product group S800 / S800P / S750 MCB

Frequently Asked Questions

What is the ABB S801S-D20 used for?

The S801S-D20 provides overload and short-circuit protection for demanding commercial and industrial electrical circuits, particularly where high breaking capacity is required.

What is the rated current of the ABB S801S-D20?

The ABB S801S-D20 has a rated current of 20 A.

What tripping characteristic does the S801S-D20 use?

The circuit breaker has a Type D tripping characteristic, making it suitable for circuits supplying loads that can produce relatively high starting or inrush currents.

What is the breaking capacity of the ABB S801S-D20?

The S801S-D20 has a maximum ultimate short-circuit breaking capacity of 50 kA at 240/415 V AC.

How many poles does the ABB S801S-D20 have?

The ABB S801S-D20 is a 1-pole high-performance miniature circuit breaker.

What is the ABB order code for the S801S-D20?

The ABB order code for the S801S-D20 is 2CCS861001R0201.

Trusted by Electrical Professionals Worldwide

ABB S800 high-performance circuit breakers are designed for demanding commercial and industrial electrical installations where reliable overload protection, rapid short-circuit interruption and high fault-current performance are essential.