ABB S403M-D16NP is a 16 A 3P+N Type D SMISSLINE TP miniature circuit breaker with protected neutral, providing overload and short-circuit protection with a 10 kA rated short-circuit capacity.

SKU: 2CCS573103R8161Alt SKU: S403MD16NPMPN: 2CCS573103R8161
Price
List Price £186.05 ex VAT
Your Price (ex VAT) Save 35%
£120.93 35% OFF
You save £65.12 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £120.93
Trade pricing is personalised to your account

Manufacturer Lead Time

£120.93

Why Choose the ABB S403M-D16NP Miniature Circuit Breaker?

The ABB S403M-D16NP is a current-limiting 3P+N miniature circuit breaker (MCB) with protected neutral, designed to protect three-phase-plus-neutral electrical circuits against overload and short-circuit conditions. Part of the ABB SMISSLINE TP S400M series, it combines four-pole protection with the installation efficiency of ABB's plug-in distribution system.

Rated at 16 A with a Type D tripping characteristic, the S403M-D16NP is particularly suited to appropriately engineered circuits supplying equipment with high starting or inrush currents. Its protection characteristics make it suitable for applications involving motors, transformers and other inductive loads where normal energisation can produce substantial transient currents.

The S403M-D16NP operates at a rated voltage of 400 V AC and provides a rated short-circuit capacity of 10 kA. Its protected neutral is rated at 100% of the nominal value of the pole conductor, while its four-module SMISSLINE plug-in construction enables efficient integration into compatible ABB distribution assemblies.

Key Advantages

  • 3P+N configuration with protected neutral for comprehensive three-phase-plus-neutral circuit protection.
  • 16 A rated current for appropriately designed industrial and equipment circuits.
  • Type D tripping characteristic suited to circuits with high starting or inrush currents.
  • 10 kA rated short-circuit capacity for dependable fault protection.
  • Neutral protected at 100% of the nominal pole-conductor value.
  • Provides both overload and short-circuit protection.
  • Energy-limiting class 3 helps reduce the energy passed during short-circuit faults.
  • Plug-in construction for efficient integration with the ABB SMISSLINE TP system.

Key Features

  • ABB SMISSLINE TP S400M series.
  • 16 A rated current.
  • 3P+N configuration with four protected poles.
  • Type D tripping characteristic.
  • 10 kA breaking capacity.
  • 400 V AC rated voltage.
  • 440 V rated insulation voltage.
  • 4 kV rated impulse withstand voltage.
  • IP20 protection rating.
  • Energy-limiting class 3.
  • 10,000-cycle electrical and mechanical endurance.
  • Plug-in connection for compatible ABB SMISSLINE TP assemblies.

Reliable Protection for High-Inrush Three-Phase Loads

The ABB S403M-D16NP protects electrical conductors and connected circuits by automatically interrupting excessive current caused by sustained overloads or short-circuit faults. Its current-limiting construction helps reduce the electrical and thermal stress associated with high fault currents.

The Type D characteristic accommodates significantly higher transient currents than characteristics intended for low- or moderate-inrush loads, making the S403M-D16NP suitable for appropriately selected motor, transformer and inductive-load circuits. Combined with its protected neutral and SMISSLINE TP plug-in architecture, it provides a practical protection solution for demanding three-phase-plus-neutral industrial circuits.

Typical Applications

  • Three-phase-plus-neutral industrial circuits.
  • Motor circuits with high starting currents.
  • Transformer and inductive-load circuits.
  • Industrial machinery and automation equipment.
  • Manufacturing and production equipment.
  • Electrical control panels and distribution assemblies.
  • ABB SMISSLINE TP distribution systems.

Technical Specifications

Series SMISSLINE TP S400M
ABB order code 2CCS573103R8161
EAN 7612270104017
Product type Miniature circuit breaker (MCB)
Pole configuration 3P+N
Total poles 4
Protected poles 4
Neutral Protected at 100% of nominal pole-conductor value
Rated current 16 A
Tripping characteristic Type D
Rated voltage 400 V AC
Rated insulation voltage 440 V
Rated impulse withstand voltage 4 kV
Rated short-circuit capacity 10 kA
Energy-limiting class 3
Protection rating IP20
Maximum conductor cross-section 35 mm²
Electrical endurance 10,000 cycles
Mechanical endurance 10,000 cycles
Operating temperature −25 to +55 °C
Protection functions Overload and short-circuit protection
Installation system ABB SMISSLINE TP plug-in system
Standards IEC/EN 60898-1, IEC/EN 60947-2
Module width 4 modules
Height 91 mm
Width 72 mm
Depth 75 mm
Weight approx. 428 g

Frequently Asked Questions

What is the ABB S403M-D16NP used for?

The ABB S403M-D16NP is a 3P+N miniature circuit breaker with protected neutral designed to protect three-phase-plus-neutral circuits against overload and short-circuit currents, particularly where connected equipment can produce high starting or inrush currents.

What is the current rating of the S403M-D16NP?

The S403M-D16NP has a rated current of 16 A.

What does the Type D tripping characteristic mean?

The Type D characteristic is intended for appropriately engineered circuits where equipment can produce high transient starting or inrush currents, such as motors, transformers and other inductive loads.

What is the breaking capacity of the ABB S403M-D16NP?

The S403M-D16NP has a rated short-circuit breaking capacity of 10 kA.

Does the ABB S403M-D16NP have a protected neutral?

Yes. The S403M-D16NP is a 3P+N device with protected neutral. The neutral is protected at 100% of the nominal value of the pole conductor, and the device is designed for integration with compatible ABB SMISSLINE TP assemblies.