2CCG001346R0001 ABB DS804P-B125/0.03AP-R 125 A 4-Pole APR 30 mA RCBO

2CCG001346R0001 ABB DS804P-B125/0.03AP-R 125 A 4-Pole APR 30 mA RCBO

ABB DS804P-B125/0.03AP-R is a 125 A four-pole B-characteristic APR RCBO with 30 mA residual-current sensitivity for combined residual-current, overload and short-circuit protection.

SKU: 2CCG001346R0001Alt SKU: DS804PB1250.03APRMPN: 2CCG001346R0001
Price
List Price £1,306.29 ex VAT
Your Price (ex VAT) Save 35%
£849.09 35% OFF
You save £457.20 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £849.09
Trade pricing is personalised to your account

Manufacturer Lead Time

£849.09

Why Choose the ABB DS804P-B125/0.03AP-R RCBO?

The ABB DS804P-B125/0.03AP-R is a high-performance four-pole residual current circuit breaker with overcurrent protection (RCBO) designed to combine residual-current, overload and short-circuit protection in one device. Part of ABB's DS800P high-performance circuit protection range, it combines a 125 A rated current, B tripping characteristic and 30 mA APR residual-current protection.

The APR characteristic is designed for enhanced resistance to unwanted tripping caused by transient disturbances while maintaining residual-current protection. This makes the DS804P-B125/0.03AP-R well suited to demanding commercial and industrial circuits where continuity of service and reliable earth-fault protection are important.

With its four-pole configuration and 30 mA rated residual operating current, the DS804P-B125/0.03AP-R provides integrated protection for multi-pole and three-phase distribution circuits. Its combined RCBO architecture reduces the need for separate overcurrent and residual-current protective devices.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one RCBO.
  • 125 A rated current for demanding distribution circuits.
  • Four-pole configuration for multi-pole and three-phase applications.
  • 30 mA rated residual operating current.
  • APR residual-current characteristic provides enhanced immunity to unwanted tripping from transient disturbances.
  • B tripping characteristic for overcurrent protection.
  • Suitable for demanding commercial and industrial electrical installations.

Key Features

  • ABB DS800P high-performance RCBO.
  • 4-pole configuration.
  • 125 A rated current.
  • B tripping characteristic.
  • 30 mA rated residual operating current.
  • APR residual-current characteristic.
  • Integrated overload protection.
  • Integrated short-circuit protection.
  • Integrated residual earth-fault current protection.
  • Enhanced resistance to nuisance tripping caused by transient disturbances.

High-Performance Residual-Current and Overcurrent Protection

The ABB DS804P-B125/0.03AP-R combines residual-current monitoring with thermal overload and magnetic short-circuit protection. This integrated design allows the device to disconnect the protected circuit when qualifying earth-fault, overload or short-circuit conditions occur, providing multiple protection functions within a single RCBO.

Its 30 mA APR characteristic combines sensitive residual-current protection with enhanced immunity to transient disturbances that can otherwise cause unwanted operation. Together with its B tripping characteristic and four-pole architecture, this makes the DS804P-B125/0.03AP-R suitable for demanding multi-pole distribution circuits where dependable protection and continuity of operation are required.

Typical Applications

  • Commercial electrical distribution systems.
  • Industrial power distribution installations.
  • Three-phase distribution boards and switchboards.
  • Industrial machinery supply circuits.
  • Circuits requiring 30 mA residual-current protection.
  • Installations susceptible to transient disturbances and unwanted residual-current tripping.
  • Circuits requiring combined residual-current and overcurrent protection.

Technical Specifications

Series DS800P
SKU DS804PB1250.03APR
ABB order code 2CCG001346R0001
Product group S800 / S800P / S750 MCB
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 4
Rated current 125 A
Tripping characteristic B
Residual-current characteristic APR
Rated residual operating current 30 mA
Protection functions Residual current, overload and short-circuit protection
Application Commercial and industrial circuit protection

Frequently Asked Questions

What is the ABB DS804P-B125/0.03AP-R used for?

The ABB DS804P-B125/0.03AP-R is a four-pole RCBO designed to provide combined residual-current, overload and short-circuit protection for demanding electrical circuits.

What is the rated current of the DS804P-B125/0.03AP-R?

The DS804P-B125/0.03AP-R has a rated current of 125 A.

What residual-current sensitivity does the DS804P-B125/0.03AP-R have?

The RCBO has a rated residual operating current of 30 mA.

What does APR mean on the DS804P-B125/0.03AP-R?

The APR characteristic provides enhanced immunity to unwanted residual-current tripping caused by transient disturbances while retaining residual-current protection.

What does the B characteristic mean on this RCBO?

The B tripping characteristic defines the device's overcurrent tripping behaviour and is suited to circuits where relatively low normal starting or inrush currents are expected.

How many poles does the ABB DS804P-B125/0.03AP-R have?

The DS804P-B125/0.03AP-R is a four-pole RCBO suitable for multi-pole and three-phase electrical distribution applications.

What is the ABB order code for the DS804P-B125/0.03AP-R?

The ABB order code for the DS804P-B125/0.03AP-R is 2CCG001346R0001.

Trusted by Electrical Professionals Worldwide

ABB DS800P high-performance RCBOs are designed for demanding commercial and industrial electrical distribution systems where dependable overload, short-circuit and residual-current protection is required in a robust integrated protective device.