2CCG001329R0001 ABB DS804P-C125/1AS RCBO 4P Type AS 1000 mA 125 A

2CCG001329R0001 ABB DS804P-C125/1AS RCBO 4P Type AS 1000 mA 125 A

ABB DS804P-C125/1AS four-pole RCBO with 125 A rated current, Type C overcurrent characteristic and 1000 mA Type AS selective residual current protection for demanding industrial and commercial electrical circuits.

SKU: 2CCG001329R0001Alt SKU: DS804PC1251ASMPN: 2CCG001329R0001
Price
List Price £1,417.66 ex VAT
Your Price (ex VAT) Save 35%
£921.48 35% OFF
You save £496.18 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £921.48
Trade pricing is personalised to your account

Manufacturer Lead Time

£921.48

Why Choose the ABB DS804P-C125/1AS RCBO?

The ABB DS804P-C125/1AS is a high-performance four-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and residual currents. As part of ABB’s high-performance circuit protection range, it integrates overcurrent and residual current protection within a single device for demanding industrial and commercial electrical installations.

Featuring a 125 A rated current, Type C overcurrent tripping characteristic and 1000 mA rated residual operating current, the DS804P-C125/1AS provides coordinated protection for higher-current distribution circuits. Its Type AS residual current characteristic provides selective, time-delayed operation for applications where discrimination with downstream residual current protective devices is required.

The four-pole configuration makes the DS804P-C125/1AS suitable for multiphase electrical distribution systems requiring coordinated switching and protection. With ABB order code 2CCG001329R0001, this RCBO is particularly suited to upstream distribution applications requiring high-current overcurrent protection combined with selective residual current protection.

Key Advantages

  • Combined residual current, overload and short-circuit protection in one device.
  • 125 A rated current for higher-current electrical circuits.
  • 1000 mA rated residual operating current.
  • Type AS selective residual current protection for coordinated protection arrangements.
  • Type C overcurrent tripping characteristic suitable for circuits with moderate inrush currents.
  • Four-pole configuration for multiphase electrical systems.
  • Integrated design simplifies protection arrangements compared with separate overcurrent and residual current devices.

Key Features

  • ABB DS800P high-performance RCBO range.
  • Four-pole configuration.
  • 125 A rated current.
  • Type C overcurrent characteristic.
  • Type AS selective residual current characteristic.
  • 1000 mA rated residual operating current.
  • Time-delayed residual current operation for selective protection arrangements.
  • Integrated overload protection.
  • Integrated short-circuit protection.
  • Integrated residual current protection.

Selective Residual Current and Overcurrent Protection

An RCBO combines residual current protection with overload and short-circuit protection in a single protective device. The ABB DS804P-C125/1AS therefore protects a circuit against excessive current while also monitoring for residual current caused by leakage to earth, disconnecting the protected circuit when the relevant operating conditions are reached.

The selective Type AS characteristic provides time-delayed residual current operation to support coordination with downstream residual current protective devices. This arrangement can allow an appropriate downstream protective device to disconnect a faulty circuit before an upstream device operates, helping maintain continuity elsewhere in the electrical distribution system.

Typical Applications

  • Industrial electrical distribution systems.
  • Commercial distribution boards.
  • Multiphase equipment and machinery circuits.
  • Industrial control and automation installations.
  • Upstream protection in installations with downstream residual current devices.
  • Circuits requiring selective residual current coordination.
  • Electrical installations requiring 1000 mA selective residual current protection.

Technical Specifications

Series DS800P
ABB order code 2CCG001329R0001
Order designation DS804PC1251AS
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Rated current 125 A
Number of poles 4
Overcurrent tripping characteristic Type C
Residual current characteristic Type AS (selective)
Rated residual operating current 1000 mA
Residual current operation Selective / time-delayed
Protection functions Overload, short circuit and residual current
Application Commercial and industrial circuit protection

Frequently Asked Questions

What is the ABB DS804P-C125/1AS used for?

The DS804P-C125/1AS provides combined overload, short-circuit and selective residual current protection for multiphase commercial and industrial electrical circuits.

What is the rated current of the DS804P-C125/1AS?

The ABB DS804P-C125/1AS has a rated current of 125 A.

What residual operating current does this RCBO have?

The DS804P-C125/1AS has a rated residual operating current of 1000 mA, equivalent to 1 A.

What does the AS characteristic mean?

The AS characteristic denotes selective, time-delayed residual current operation, helping provide discrimination between upstream and downstream residual current protective devices.

What does the Type C overcurrent characteristic mean?

The Type C overcurrent characteristic is suitable for many commercial and industrial circuits where moderate inrush or starting currents can occur during normal operation.

Trusted High-Performance Circuit Protection from ABB

ABB high-performance protective devices provide dependable overload, short-circuit and residual current protection for demanding industrial and commercial electrical systems, including selective protection arrangements designed to support continuity across distribution networks.