2CCG001326R0001 ABB DS804P-B125/0.3AS 125 A 4-Pole Type AS 300 mA RCBO

2CCG001326R0001 ABB DS804P-B125/0.3AS 125 A 4-Pole Type AS 300 mA RCBO

ABB DS804P-B125/0.3AS is a 125 A four-pole B-characteristic Type AS selective RCBO with 300 mA residual-current sensitivity and 50 kA ultimate short-circuit breaking capacity for industrial circuit protection.

SKU: 2CCG001326R0001Alt SKU: DS804PB1250.3ASMPN: 2CCG001326R0001
Price
List Price £1,492.30 ex VAT
Your Price (ex VAT) Save 35%
£970.00 35% OFF
You save £522.31 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £970.00
Trade pricing is personalised to your account

Manufacturer Lead Time

£970.00

Why Choose the ABB DS804P-B125/0.3AS RCBO?

The ABB DS804P-B125/0.3AS is a high-performance four-pole residual current circuit breaker with overcurrent protection (RCBO) designed for demanding industrial electrical installations. Part of the ABB DS800P high-performance protection range, it combines overload, short-circuit and residual-current protection in one device, with a 125 A rated current, B tripping characteristic and 300 mA rated residual operating current.

This model uses ABB's Type AS selective residual-current characteristic. It is pulse-current sensitive and incorporates an intentional tripping delay, allowing residual-current selectivity with suitable downstream instantaneous protective devices. This makes it particularly useful in industrial distribution systems where coordinated protection and continuity of supply are important.

With four protected poles, a rated operational voltage up to 690 V AC and an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, the DS804P-B125/0.3AS provides robust protection for demanding three-phase distribution circuits. It is designed to IEC/EN 60947-2 for industrial applications.

Key Advantages

  • Combined residual-current, overload and short-circuit protection in one RCBO.
  • 125 A rated current for demanding industrial distribution circuits.
  • Four-pole configuration with four protected poles.
  • 300 mA Type AS selective residual-current protection.
  • Intentional residual-current tripping delay supports selectivity with suitable downstream instantaneous devices.
  • High 50 kA ultimate short-circuit breaking capacity at 415 V AC.
  • B tripping characteristic for overcurrent protection.

Key Features

  • ABB DS800P high-performance RCBO series.
  • 4-pole configuration.
  • 125 A rated current.
  • B tripping characteristic.
  • 300 mA rated residual operating current.
  • Type AS selective residual-current characteristic.
  • 50 kA Icu at 415 V AC.
  • 40 kA Ics at 240 / 415 V AC.
  • 50–60 Hz rated frequency.
  • Designed in accordance with IEC/EN 60947-2.

Selective Protection for Industrial Distribution Systems

The ABB DS804P-B125/0.3AS combines thermal and magnetic overcurrent protection with residual-current monitoring, allowing one device to protect against overload currents, short circuits and earth-fault currents. Its high short-circuit breaking capacity supports use in industrial systems with substantial prospective fault levels.

The Type AS characteristic incorporates intentional residual-current tripping delay. This enables selective coordination with suitable downstream instantaneous residual-current devices so that a downstream fault can be cleared locally without unnecessarily disconnecting a larger upstream section of the installation.

Typical Applications

  • Industrial power distribution systems.
  • Three-phase distribution boards and switchboards.
  • Industrial machinery supply circuits.
  • Circuits requiring selective residual-current protection.
  • Industrial installations with downstream residual-current protective devices.
  • Resistive and inductive load circuits.
  • Installations requiring high short-circuit breaking capacity.

Technical Specifications

Series DS800P
SKU DS804PB1250.3AS
ABB order code 2CCG001326R0001
Product group S800 / S800P / S750 MCB
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Number of poles 4
Protected poles 4
Rated current 125 A
Tripping characteristic B
Residual-current characteristic Type AS, selective
Rated residual operating current 300 mA
Rated operational voltage Up to 690 V AC
Rated frequency 50–60 Hz
Ultimate short-circuit breaking capacity (Icu) 50 kA at 415 V AC
Service short-circuit breaking capacity (Ics) 40 kA at 240 / 415 V AC
Standard IEC/EN 60947-2
Application Industrial
Dimensions (H × W × D) approx. 108.2 × 227.5 × 82.3 mm

Frequently Asked Questions

What is the ABB DS804P-B125/0.3AS used for?

The ABB DS804P-B125/0.3AS provides combined overload, short-circuit and residual-current protection for demanding industrial electrical circuits.

What is the rated current of the DS804P-B125/0.3AS?

The DS804P-B125/0.3AS has a rated current of 125 A.

What residual-current sensitivity does this RCBO have?

The device has a rated residual operating current of 300 mA.

What does Type AS mean on the DS804P-B125/0.3AS?

Type AS denotes pulse-current-sensitive selective residual-current protection with an intentional tripping delay, allowing coordination with suitable downstream instantaneous residual-current devices.

What is the breaking capacity of the DS804P-B125/0.3AS?

The DS804P-B125/0.3AS has an ultimate short-circuit breaking capacity Icu of 50 kA at 415 V AC.

How many poles does the ABB DS804P-B125/0.3AS have?

The DS804P-B125/0.3AS is a four-pole RCBO with four protected poles.

What is the ABB order code for the DS804P-B125/0.3AS?

The ABB order code is 2CCG001326R0001.

Trusted by Electrical Professionals Worldwide

ABB DS800P high-performance RCBOs are designed for demanding industrial power distribution systems where dependable overcurrent protection, residual-current protection, high breaking capacity and selective coordination are required.