ABB DS804P-K125/0.3A is a four-pole 125 A Type A RCBO with 300 mA residual-current protection, K tripping characteristic and 50 kA ultimate breaking capacity at 415 V AC for industrial electrical distribution systems.

SKU: 2CCG001321R0001Alt SKU: DS804PK1250.3AMPN: 2CCG001321R0001
Price
List Price £1,616.27 ex VAT
Your Price (ex VAT) Save 35%
£1,050.58 35% OFF
You save £565.69 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,050.58
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,050.58

Why Choose the ABB DS804P-K125/0.3A RCBO?

The ABB DS804P-K125/0.3A is a high-performance four-pole residual current circuit breaker with overcurrent protection (RCBO) designed for industrial electrical distribution systems. As part of the ABB DS800P range, it combines protection against overloads, short circuits and residual earth fault currents within a single protective device.

Designed for demanding industrial applications, the DS804P-K125/0.3A combines a 125 A rated current with a 300 mA rated residual operating current. Its Type A residual-current protection detects sinusoidal AC residual currents and pulsating DC residual currents, while the K tripping characteristic is suited to circuits and equipment where higher starting currents may occur.

The four-pole configuration provides simultaneous switching across a three-phase system with neutral, while a high 50 kA ultimate short-circuit breaking capacity at 415 V AC provides robust protection for industrial distribution applications. Manufactured to IEC/EN 60947-2, the DS804P-K125/0.3A is designed for reliable circuit protection in installations requiring high breaking capacity.

Key Advantages

  • Combines residual-current, overload and short-circuit protection in one device.
  • 125 A rated current for demanding industrial circuits.
  • 300 mA rated residual current for earth-fault protection.
  • Type A residual-current protection for AC and pulsating DC residual currents.
  • K tripping characteristic suitable for loads with higher starting currents.
  • High 50 kA ultimate breaking capacity at 415 V AC.
  • Four-pole configuration with simultaneously switched neutral conductor.
  • Designed for industrial applications in accordance with IEC/EN 60947-2.

Key Features

  • ABB DS800P RCBO range.
  • 125 A rated operational current.
  • 300 mA rated residual operating current.
  • Four protected poles.
  • Type A residual-current characteristic.
  • K overcurrent tripping characteristic.
  • 50 kA Icu at 415 V AC.
  • Rated operational voltage up to 690 V AC in accordance with IEC 60947-2.
  • 50–60 Hz rated frequency.
  • Compatible with accessories for the ABB high-performance circuit protection range.

High-Performance Circuit Protection for Industrial Systems

RCBOs combine residual-current protection with protection against overload and short-circuit currents, allowing multiple electrical hazards to be addressed by a single protective device. The ABB DS804P-K125/0.3A is engineered specifically for industrial installations where high current ratings and substantial short-circuit breaking capacity are required.

Its Type A residual-current functionality provides protection against sinusoidal alternating and pulsating DC earth fault currents. Combined with its K characteristic and four-pole configuration, this makes the device suitable for protecting three-phase industrial circuits, machinery and distribution systems where dependable operation under demanding electrical conditions is essential.

Typical Applications

  • Industrial electrical distribution systems.
  • Three-phase circuits with neutral conductors.
  • Industrial machinery and production equipment.
  • Motor and inductive-load circuits with higher starting currents.
  • Distribution boards and industrial switchgear assemblies.
  • Manufacturing and process automation installations.
  • Commercial and industrial infrastructure requiring high breaking capacity.

Technical Specifications

Series DS800P
ABB order code 2CCG001321R0001
Product type Residual current circuit breaker with overcurrent protection (RCBO)
Residual-current type Type A
Rated current 125 A
Rated residual current 300 mA
Tripping characteristic K
Number of poles 4P
Number of protected poles 4
Neutral conductor Simultaneously switched
Rated operational voltage Up to 690 V AC
Rated frequency 50–60 Hz
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 50 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 30 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 10 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 4.5 kA
Rated service short-circuit breaking capacity (Ics) at 240/415 V AC 40 kA
Standard IEC/EN 60947-2
Dimensions (H × W × D) 108.2 × 227.5 × 82.3 mm
Product net weight approx. 1.76 kg
EAN / GTIN 7612271517908

Frequently Asked Questions

What is the ABB DS804P-K125/0.3A used for?

The ABB DS804P-K125/0.3A is an industrial RCBO designed to protect electrical circuits against overloads, short circuits and residual earth fault currents.

What is the rated current of the DS804P-K125/0.3A?

The device has a rated current of 125 A and uses a K tripping characteristic.

What is the residual-current rating?

The DS804P-K125/0.3A has a rated residual operating current of 300 mA and provides Type A residual-current protection.

What is the breaking capacity of the ABB DS804P-K125/0.3A?

The device has an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, making it suitable for demanding industrial distribution applications.

How many poles does the DS804P-K125/0.3A have?

The DS804P-K125/0.3A is a four-pole RCBO with four protected poles and a simultaneously switched neutral conductor, making it suitable for three-phase circuits with neutral.

Trusted Industrial Circuit Protection from ABB

ABB DS800P residual current circuit breakers with overcurrent protection combine high short-circuit performance with residual-current protection for demanding industrial electrical distribution and machinery applications.