Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB DS803P-K125/0.3A is a 125 A three-pole K-characteristic Type A RCBO with 300 mA residual-current sensitivity for combined residual-current, overload and short-circuit protection in demanding three-phase installations.
£869.95
The ABB DS803P-K125/0.3A is a high-performance three-pole residual current circuit breaker with overcurrent protection (RCBO) designed to provide combined protection against overloads, short circuits and residual earth-fault currents. Part of ABB's high-performance circuit protection range, it combines a 125 A rated current, K tripping characteristic and 300 mA Type A residual-current sensitivity in a single protective device.
Type A residual-current protection enables the DS803P-K125/0.3A to respond to sinusoidal AC residual currents as well as pulsating DC residual currents. Combined with its K-characteristic overcurrent protection, the device is particularly suited to demanding commercial and industrial circuits where connected equipment can produce functional peak or inrush currents during normal operation.
With a three-pole configuration and 300 mA rated residual operating current, the DS803P-K125/0.3A provides integrated residual-current and overcurrent protection for three-phase electrical systems. Its combined RCBO design helps simplify circuit protection by incorporating multiple protective functions within one device.
The ABB DS803P-K125/0.3A combines residual-current monitoring with thermal and magnetic overcurrent protection. The RCBO disconnects the protected circuit when qualifying earth-leakage, overload or short-circuit conditions occur, allowing a single protective device to provide multiple forms of circuit protection.
Its Type A residual-current characteristic provides detection of sinusoidal AC and pulsating DC residual currents, while the K tripping characteristic is suited to circuits where functional current peaks can occur during normal equipment operation. These characteristics make the DS803P-K125/0.3A suitable for demanding three-phase distribution, machinery, motor and industrial equipment circuits.
| Series | DS803P |
|---|---|
| SKU | DS803PK1250.3A |
| ABB order code | 2CCG001317R0001 |
| Product group | S800 / S800P / S750 MCB |
| Product type | Residual current circuit breaker with overcurrent protection (RCBO) |
| Number of poles | 3 |
| Rated current | 125 A |
| Tripping characteristic | K |
| Residual-current type | Type A |
| Rated residual operating current | 300 mA |
| Protection functions | Residual current, overload and short-circuit protection |
| Application | Three-phase commercial and industrial circuit protection |
The ABB DS803P-K125/0.3A is an RCBO designed to protect three-phase electrical circuits against residual earth-fault currents, overloads and short circuits.
The DS803P-K125/0.3A has a rated current of 125 A.
The DS803P-K125/0.3A has a rated residual operating current of 300 mA.
Type A residual-current protection is designed to respond to sinusoidal AC residual currents and pulsating DC residual currents.
The K tripping characteristic is suited to circuits that can experience functional peak or inrush currents, including motor, transformer and other industrial equipment applications.
The DS803P-K125/0.3A is a three-pole RCBO designed for three-phase circuit protection.
The ABB order code for the DS803P-K125/0.3A is 2CCG001317R0001.
ABB high-performance circuit protection devices are used in demanding commercial and industrial electrical systems where dependable overload, short-circuit and residual-current protection is required for safe and reliable power distribution.
We use cookies