2CCG000528R0001 ABB S403P-B3NP MCB 40 kA 3P+NP Type B 3 A

2CCG000528R0001 ABB S403P-B3NP MCB 40 kA 3P+NP Type B 3 A

ABB S403P-B3NP 3P+NP 3 A Type B miniature circuit breaker with 40 kA Icu breaking capacity, designed for the SMISSLINE TP plug-in distribution system.

SKU: 2CCG000528R0001Alt SKU: S403PB3NPMPN: 2CCG000528R0001
Price
List Price £265.52 ex VAT
Your Price (ex VAT) Save 35%
£172.59 35% OFF
You save £92.93 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £172.59
Trade pricing is personalised to your account

Manufacturer Lead Time

£172.59

Why Choose the ABB S403P-B3NP Miniature Circuit Breaker?

The ABB S403P-B3NP is a high-performance three-pole plus protected neutral miniature circuit breaker (MCB) designed to protect electrical circuits against overload and short-circuit currents. As part of the ABB S400P series for the SMISSLINE TP plug-in system, it combines high fault-current interruption capability with ABB's practical plug-in distribution architecture.

Featuring a Type B tripping characteristic and a rated current of 3 A, the S403P-B3NP is designed for three-phase plus neutral circuits requiring dependable low-current overcurrent protection. Its 3P+NP configuration provides three phase poles together with a protected neutral pole, making it suitable for compatible four-pole distribution applications.

The S403P-B3NP provides a rated ultimate short-circuit breaking capacity of 40 kA according to IEC/EN 60947-2. Its four-module SMISSLINE TP plug-in format supports efficient installation and replacement in compatible socket-base assemblies, making it a dependable solution for industrial and commercial electrical distribution.

Key Advantages

  • High-performance 3P+NP miniature circuit breaker for three-phase plus neutral circuits.
  • 3 A rated current for suitable low-current electrical circuits.
  • Type B tripping characteristic for dependable overload and short-circuit protection.
  • High 40 kA Icu breaking capacity according to IEC/EN 60947-2.
  • Protected neutral configuration for suitable four-pole distribution circuits.
  • Designed for the ABB SMISSLINE TP plug-in system for efficient installation and maintenance.

Key Features

  • ABB S400P miniature circuit breaker series.
  • 3P+NP pole configuration.
  • 3 A rated current.
  • Type B tripping characteristic.
  • 40 kA Icu rated ultimate short-circuit breaking capacity.
  • Designed in accordance with IEC/EN 60947-2.
  • Four-module device format.
  • 0.460 kg unit weight.
  • Direct integration with compatible SMISSLINE TP socket-base systems.

Reliable Protection for Three-Phase and Neutral Circuits

Miniature circuit breakers such as the ABB S403P-B3NP automatically disconnect an electrical circuit when excessive current caused by an overload or short circuit occurs. This helps protect cables, conductors, connected equipment and distribution infrastructure against thermal and electrical damage associated with overcurrent conditions.

The ABB SMISSLINE TP system uses a plug-in architecture that allows compatible protective devices to be integrated efficiently with its socket-base system. Combined with the S403P-B3NP's 3P+NP configuration and high short-circuit breaking capacity, this provides an effective protection solution for professional industrial and commercial distribution installations.

Typical Applications

  • Three-phase plus neutral electrical circuits.
  • Industrial electrical distribution boards.
  • Commercial power distribution systems.
  • Machinery and industrial control panels.
  • Automation and manufacturing installations.
  • ABB SMISSLINE TP plug-in distribution assemblies.

Technical Specifications

Series S400P
Product system SMISSLINE TP Plug-in System
ABB order code 2CCG000528R0001
EAN / GTIN 7612271508982
Product type Miniature circuit breaker (MCB)
Pole configuration 3P+NP
Total number of poles 4
Neutral Protected neutral
Rated current 3 A
Tripping characteristic Type B
Rated ultimate short-circuit breaking capacity (Icu) 40 kA
Standard IEC/EN 60947-2
Number of modules 4
Weight 0.460 kg
Pack quantity 2 pieces
Mounting type SMISSLINE TP plug-in socket-base system

Frequently Asked Questions

What is the ABB S403P-B3NP used for?

The ABB S403P-B3NP is a 3P+NP miniature circuit breaker designed to protect compatible three-phase plus neutral circuits against overload and short-circuit currents.

What is the rated current of the S403P-B3NP?

The S403P-B3NP has a rated current of 3 A.

What tripping characteristic does the S403P-B3NP use?

The S403P-B3NP uses a Type B tripping characteristic for dependable overcurrent protection.

What is the breaking capacity of the ABB S403P-B3NP?

The S403P-B3NP has a rated ultimate short-circuit breaking capacity (Icu) of 40 kA according to IEC/EN 60947-2.

Which ABB distribution system is the S403P-B3NP designed for?

The circuit breaker is designed for the ABB SMISSLINE TP plug-in system, enabling integration with compatible socket-base electrical distribution assemblies.

Trusted ABB Circuit Protection

ABB SMISSLINE TP circuit protection products combine dependable electrical protection with a flexible plug-in architecture, supporting efficient installation, expansion and maintenance in professional industrial and commercial distribution systems.