ABB S403P-C50 is a 50 A Type C 3-pole miniature circuit breaker with 20 kA ultimate short-circuit breaking capacity, designed for overload and short-circuit protection in SMISSLINE TP plug-in distribution systems.

SKU: 2CCG000393R0001Alt SKU: S403PC50MPN: 2CCG000393R0001
Price
List Price £247.72 ex VAT
Your Price (ex VAT) Save 35%
£161.02 35% OFF
You save £86.70 per unit
Manufacturer Lead Time Estimated Delivery 7 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £161.02
Trade pricing is personalised to your account

Manufacturer Lead Time

£161.02

Why Choose the ABB S403P-C50 Miniature Circuit Breaker?

The ABB S403P-C50 is a high-performance 3-pole miniature circuit breaker (MCB) designed to provide reliable overload and short-circuit protection in commercial and industrial electrical distribution systems. As part of the ABB S400P range for the SMISSLINE TP plug-in system, it combines robust circuit protection with a convenient plug-in format for compatible distribution assemblies.

The S403P-C50 uses thermal overload protection together with electromagnetic short-circuit protection to safeguard cables, conductors and connected equipment. Its Type C tripping characteristic is suitable for circuits where moderate starting or inrush currents can occur, while the three-pole configuration provides coordinated protection across three conductors.

With a rated current of 50 A, a 3-pole configuration and a rated ultimate short-circuit breaking capacity of 20 kA, the S403P-C50 is designed for demanding SMISSLINE TP distribution applications. ABB order code 2CCG000393R0001 identifies this specific 50 A Type C version.

Key Advantages

  • High-performance 3-pole miniature circuit breaker for overload and short-circuit protection.
  • 50 A rated current for three-phase distribution and equipment circuits.
  • Type C tripping characteristic suitable for loads with moderate inrush currents.
  • 20 kA ultimate short-circuit breaking capacity for demanding electrical distribution applications.
  • Thermal overload and electromagnetic short-circuit tripping mechanisms.
  • Direct plug-in connection designed for the ABB SMISSLINE TP socket system.

Key Features

  • ABB S400P / SMISSLINE TP series.
  • 50 A rated current.
  • 3-pole configuration.
  • Type C tripping characteristic.
  • 20 kA rated ultimate short-circuit breaking capacity.
  • Designed in accordance with IEC/EN 60947-2.
  • Current-limiting miniature circuit breaker design.
  • Direct contact with the compatible SMISSLINE TP plug-in socket system.
  • Connection terminals accept conductors up to 35 mm².
  • IP20 protection at the insulated connection terminal.

Reliable Circuit Protection for Three-Phase Systems

Miniature circuit breakers such as the ABB S403P-C50 protect cables and conductors against damaging overload and short-circuit currents. The thermal trip responds to sustained overload conditions, while the electromagnetic trip provides rapid disconnection during short-circuit faults, helping to protect the electrical installation.

The ABB SMISSLINE TP architecture allows compatible protective devices to connect directly to the plug-in socket system. This provides a practical approach to assembling and maintaining distribution systems, while the three-pole S403P-C50 provides coordinated protection for three-phase circuits requiring a 50 A Type C protective device.

Typical Applications

  • Industrial three-phase electrical distribution systems.
  • Commercial building distribution boards.
  • SMISSLINE TP plug-in distribution assemblies.
  • Machine and automation control panels.
  • Three-phase equipment and auxiliary circuits.
  • Electrical installations with moderate load inrush currents.
  • Branch circuit overload and short-circuit protection.

Technical Specifications

Series S400P / SMISSLINE TP
ABB order code 2CCG000393R0001
Product type Miniature circuit breaker (MCB)
Rated current 50 A
Number of poles 3
Tripping characteristic Type C
Rated ultimate short-circuit breaking capacity 20 kA
Standard IEC/EN 60947-2
Mounting system SMISSLINE TP plug-in system
Maximum conductor cross-section 35 mm²
Protection at connection terminal IP20
Module width 3 modules
Weight approx. 345 g

Frequently Asked Questions

What is the ABB S403P-C50 used for?

The ABB S403P-C50 is a 3-pole miniature circuit breaker designed to protect electrical circuits, cables and connected equipment against overload and short-circuit currents in compatible SMISSLINE TP installations.

What is the rated current of the S403P-C50?

The ABB S403P-C50 has a rated current of 50 A.

What tripping characteristic does the S403P-C50 use?

The S403P-C50 uses a Type C tripping characteristic, making it suitable for circuits where moderate starting or inrush currents can occur.

What is the breaking capacity of the ABB S403P-C50?

The S403P-C50 has a rated ultimate short-circuit breaking capacity of 20 kA.

Which mounting system is the S403P-C50 designed for?

The S403P-C50 is designed for the ABB SMISSLINE TP plug-in system, allowing direct connection to compatible SMISSLINE TP socket assemblies.

Trusted Circuit Protection from ABB

ABB SMISSLINE TP S400P miniature circuit breakers combine dependable overload and short-circuit protection with a practical plug-in architecture for commercial and industrial electrical distribution systems.