ABB F404A-K63/0.03 is a 63 A four-pole Type A 30 mA short-time delayed residual current circuit breaker rated at 230/400 V for plug-in installation in ABB SMISSLINE TP low-voltage distribution systems.
£290.67
The ABB F404A-K63/0.03 is a short-time delayed Type A residual current circuit breaker (RCCB) designed for the ABB SMISSLINE TP plug-in distribution system. Rated at 63 A with a rated residual operating current of 30 mA, it provides four-pole residual-current protection for compatible low-voltage circuits.
As part of the ABB F404 K series, this RCCB combines Type A residual-current detection with a short-time delayed operating characteristic. It is sensitive to sinusoidal AC and pulsating DC residual currents, while the delayed characteristic provides increased resistance to unwanted tripping caused by short-duration transient leakage currents.
The F404A-K63/0.03 features a four-pole configuration, 63 A rated current, 30 mA residual-current sensitivity and 230/400 V rated voltage. It occupies four SMISSLINE space units and integrates directly with the modular SMISSLINE TP system for efficient and flexible distribution-board assembly.
Residual current circuit breakers monitor the balance of current flowing through the protected conductors and disconnect the circuit when residual current reaches the device's operating threshold. The F404A-K63/0.03 combines 30 mA Type A residual-current protection with ABB's short-time delayed K characteristic, providing increased immunity to brief transient residual currents.
The ABB F404 K series is designed specifically for integration with the SMISSLINE TP plug-in distribution system. Integrated input wiring, flexible plug-in positioning and a double-level output terminal arrangement help provide an efficient solution for commercial and industrial distribution assemblies requiring dependable residual-current protection.
| Series | F404 K / SMISSLINE TP |
|---|---|
| ABB order code | 2CCF544310E0630 |
| Product type | Short-time delayed residual current circuit breaker (RCCB) |
| Residual-current type | Type A |
| Tripping characteristic | K, short-time delayed |
| Number of poles | 4 |
| Rated current | 63 A |
| Rated residual operating current | 30 mA |
| Rated voltage | 230/400 V |
| Frequency | 50–60 Hz |
| Power loss | 3.2 W |
| Space units | 4 |
| Mounting type | SMISSLINE TP plug-in / conductor bar mounting |
| Standard | EN 61008-1 |
| Dimensions (W × H × D) | 72 × 91 × 75 mm |
| Weight | 0.430 kg |
| Pack unit | 1 piece |
| System | ABB SMISSLINE TP |
It is a four-pole short-time delayed Type A RCCB designed to provide residual-current protection in compatible ABB SMISSLINE TP low-voltage distribution systems.
The RCCB has a rated current of 63 A.
The F404A-K63/0.03 has a rated residual operating current of 30 mA.
The K designation identifies the short-time delayed version of the ABB F404 RCCB, providing increased resistance to unwanted operation from brief transient residual currents.
The ABB order code for the F404A-K63/0.03 is 2CCF544310E0630.
ABB F404 K residual current circuit breakers combine short-time delayed Type A residual-current protection with the modular plug-in architecture of the SMISSLINE TP system, supporting dependable and flexible low-voltage distribution installations.