1SDA104958R1 ABB YU-C XT5-XT6 F/P Undervoltage Release 220–240 V AC / 220–250 V DC

1SDA104958R1 ABB YU-C XT5-XT6 F/P Undervoltage Release 220–240 V AC / 220–250 V DC

ABB 1SDA104958R1 YU-C wired undervoltage release for fixed and plug-in SACE Tmax XT5 and XT6 circuit breakers, rated for 220–240 V AC or 220–250 V DC control supplies.

SKU: 1SDA104958R1MPN: 1SDA104958R1
Price
List Price £171.33 ex VAT
Your Price (ex VAT) Save 25%
£128.50 25% OFF
You save £42.83 per unit
Manufacturer Lead Time Estimated Delivery 4 - 5 Days
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £128.50
Trade pricing is personalised to your account

Manufacturer Lead Time

£128.50

Why Choose the ABB YU-C XT5-XT6 F/P 220–240 V AC / 220–250 V DC Undervoltage Release?

The ABB 1SDA104958R1, designated YU-C XT5-XT6 F/P 220–240 V AC / 220–250 V DC, is a wired undervoltage release (UVR) designed for ABB SACE Tmax XT5 and XT6 moulded-case circuit breakers. It provides an electrical tripping function when the control supply voltage falls below the release operating threshold, helping protect equipment and machinery from unsafe operation during undervoltage conditions.

As part of the ABB SACE Tmax XT electrical accessory range, the YU-C undervoltage release is engineered for direct integration with compatible XT5 and XT6 circuit breakers. This version is intended for fixed and plug-in breaker configurations and is supplied as a wired accessory for straightforward installation within electrical distribution and control systems.

The 1SDA104958R1 version is rated for a control voltage of 220–240 V AC or 220–250 V DC. Its dual AC/DC voltage compatibility makes it suitable for a broad range of industrial switchboards, machinery panels and power-distribution applications requiring dependable undervoltage protection.

Key Advantages

  • Dedicated undervoltage release for ABB Tmax XT5 and XT6 circuit breakers.
  • Supports 220–240 V AC control supplies.
  • Supports 220–250 V DC control supplies.
  • Compatible with fixed and plug-in XT5/XT6 breaker versions.
  • Wired YU-C configuration simplifies integration into control circuits.
  • Automatically assists circuit-breaker tripping during unacceptable control-voltage loss.

Key Features

  • ABB SACE Tmax XT accessory range.
  • YU-C wired undervoltage release.
  • 220–240 V AC rated control voltage.
  • 220–250 V DC rated control voltage.
  • Designed for XT5 and XT6 frame sizes.
  • Suitable for fixed and plug-in circuit breakers.
  • Electrical accessory for automatic breaker release under undervoltage conditions.
  • Designed for industrial power-distribution and machinery-protection applications.

Reliable Undervoltage Protection for Circuit Breakers

Undervoltage releases are used to trip a circuit breaker when the control supply falls below an acceptable level. This helps prevent connected machinery or electrical equipment from remaining energised or automatically restarting under unsuitable voltage conditions.

The ABB YU-C accessory integrates directly with compatible SACE Tmax XT circuit breakers, providing an electrically controlled release mechanism as part of the breaker protection and control system. Its wired format and compatibility with both AC and DC control supplies make it suitable for industrial switchboards, automation panels and power-distribution assemblies.

Typical Applications

  • Industrial electrical distribution panels.
  • ABB SACE Tmax XT5 and XT6 circuit-breaker installations.
  • Machine control and automation panels.
  • Motor control centres and switchboards.
  • Power-distribution systems requiring undervoltage tripping.
  • Fixed and plug-in moulded-case circuit-breaker assemblies.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA104958R1
Product type Wired undervoltage release
Accessory type Undervoltage Release (UVR)
Rated AC voltage 220–240 V AC
Rated DC voltage 220–250 V DC
Compatible frame sizes XT5 / XT6
Circuit-breaker versions Fixed / plug-in
Standards IEC 60947-2 / UL 489
Weight 0.143 kg

Frequently Asked Questions

What is the ABB 1SDA104958R1 used for?

The ABB 1SDA104958R1 is a wired undervoltage release used with compatible ABB SACE Tmax XT5 and XT6 circuit breakers to initiate breaker release when the control voltage falls below the required operating level.

What control voltage does this undervoltage release use?

This YU-C release is rated for 220–240 V AC or 220–250 V DC control supplies.

Which ABB circuit breakers are compatible with 1SDA104958R1?

The accessory is designed for ABB SACE Tmax XT5 and XT6 circuit breakers.

Is the ABB 1SDA104958R1 suitable for fixed and plug-in breakers?

Yes. This YU-C version is specified for compatible fixed and plug-in XT5 and XT6 circuit breakers.

Why is an undervoltage release used with a circuit breaker?

An undervoltage release helps trip the circuit breaker when the control voltage becomes too low, supporting safer operation of machinery and electrical distribution systems during supply-voltage disturbances.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit-breaker accessories are widely used in industrial power distribution, machinery and automation systems where dependable electrical protection, control and integration are essential.