Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA101956R1 XT4X 160 MA is a 10 A three-pole fixed moulded case circuit breaker with front terminals, an adjustable 50–100 A magnetic trip setting and 200 kA short-circuit breaking capacity at 415 V AC for demanding motor protection applications.
£1,552.59
The ABB 1SDA101956R1 is a SACE Tmax XT4X moulded case circuit breaker (MCCB) designed particularly for motor short-circuit protection in demanding low-voltage electrical systems. This three-pole fixed breaker uses ABB’s MA magnetic release, with a rated current of 10 A and an adjustable instantaneous magnetic trip setting of 50–100 A.
As part of the ABB SACE Tmax XT family, the XT4X combines the compact XT4 frame with exceptionally high short-circuit interruption performance. The X performance level provides an ultimate short-circuit breaking capacity of 200 kA at 415 V AC, making the 1SDA101956R1 suitable for motor circuits installed in systems with very high prospective fault currents.
The 1SDA101956R1 is supplied as a fixed three-pole circuit breaker with front terminals. Its MA release is dedicated primarily to instantaneous short-circuit protection rather than conventional thermal overload protection, making it particularly suitable for motor circuits where appropriately coordinated overload protection is provided separately.
The MA magnetic release is designed to respond rapidly to high short-circuit currents while allowing the protection threshold to be coordinated with motor starting characteristics. On the 1SDA101956R1, the instantaneous magnetic threshold is adjustable between 50 A and 100 A, equivalent to 5–10 times the breaker’s 10 A rated current. This allows the breaker to tolerate appropriate motor starting currents while providing rapid interruption of severe short-circuit faults.
The XT4X performance level is particularly suited to installations with exceptionally high prospective fault currents, delivering 200 kA Icu and Ics at 415 V AC. Because the MA release is intended for magnetic short-circuit protection, suitable motor overload protection should be provided separately and coordinated with the breaker as part of the complete motor protection system.
| Series | SACE Tmax XT |
|---|---|
| Order code | 1SDA101956R1 |
| GTIN / EAN | 8056221020008 |
| Product type | Moulded case circuit breaker |
| Application type | Motor protection |
| Frame | XT4 160 |
| Performance level | XT4X |
| Rated current | 10 A |
| Rated uninterrupted frame current | 160 A |
| Number of poles | 3 |
| Trip unit | MA |
| Release type | Magnetic |
| Instantaneous magnetic trip setting | 50–100 A |
| Magnetic adjustment | 5–10 × In |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 200 kA |
| Service short-circuit breaking capacity (Ics) at 415 V AC | 200 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 100 kA |
| Rated operational voltage | 690 V AC / 750 V DC |
| Rated insulation voltage | 1000 V |
| Rated impulse withstand voltage | 8 kV |
| Mounting type | Fixed |
| Terminal connection | Front terminals |
| Product net dimensions (W × H × D) | 105 × 160 × 82.5 mm |
| Product net weight | 1.3 kg |
| Application | Motor short-circuit protection and high-fault-level low-voltage circuits |
The ABB 1SDA101956R1 is a 10 A three-pole XT4X moulded case circuit breaker designed particularly for magnetic short-circuit protection of motors and compatible low-voltage circuits.
The breaker uses an ABB MA magnetic release. It provides adjustable instantaneous magnetic short-circuit protection rather than conventional thermal overload protection.
The instantaneous magnetic trip setting is adjustable from 50 A to 100 A, corresponding to 5–10 times the breaker’s 10 A rated current.
The XT4X performance level provides an ultimate short-circuit breaking capacity of 200 kA at 415 V AC. For this configuration, ABB also specifies a service short-circuit breaking capacity of 200 kA at 415 V AC.
The MA release is designed primarily for magnetic short-circuit protection and does not provide conventional thermal overload protection. For motor applications, an appropriately selected and coordinated external overload protective device should therefore be used.
ABB SACE Tmax XT moulded case circuit breakers provide compact and dependable protection for industrial low-voltage systems, with XT4X breakers and MA magnetic releases combining exceptionally high short-circuit interruption performance with dedicated motor short-circuit protection.
We use cookies