1SDA101810R1 ABB XT7L M 800 Ekip G Hi-Touch LSIG 800 A 4-Pole Circuit Breaker

1SDA101810R1 ABB XT7L M 800 Ekip G Hi-Touch LSIG 800 A 4-Pole Circuit Breaker

ABB 1SDA101810R1 is an XT7L M 800 four-pole fixed moulded case circuit breaker rated at 800 A with front terminals, 120 kA ultimate breaking capacity at 380–415 V AC and Ekip G Hi-Touch LSIG electronic protection.

SKU: 1SDA101810R1MPN: 1SDA101810R1
Price
List Price £12,814.55 ex VAT
Your Price (ex VAT) Save 25%
£9,610.91 25% OFF
You save £3,203.64 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £9,610.91
Trade pricing is personalised to your account

Manufacturer Lead Time

£9,610.91

Why Choose the ABB XT7L M 800 Ekip G Hi-Touch LSIG Circuit Breaker?

The ABB XT7L M 800 Ekip G Hi-Touch LSIG, order code 1SDA101810R1, is a high-performance SACE Tmax XT moulded case circuit breaker engineered for sophisticated generator and low-voltage power-system protection. This four-pole breaker has a rated uninterrupted current of 800 A and combines the XT7L high-breaking-capacity platform with ABB's advanced Ekip G Hi-Touch LSIG electronic release.

The Ekip G Hi-Touch LSIG solid-state release provides long-time, short-time, instantaneous and earth-fault protection functions, with the Ekip G platform specifically suited to generator protection applications. The Hi-Touch architecture supports advanced protection requirements where accurate electronic control and comprehensive fault protection are important.

The 1SDA101810R1 is supplied as a four-pole fixed circuit breaker with front terminals, stored-energy operating mechanism and lever operating mechanism. Its XT7L configuration provides an ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, making it suitable for demanding generator switchboards, industrial distribution systems and other installations with high prospective fault currents.

Key Advantages

  • Advanced 800 A generator and distribution protection from the ABB SACE Tmax XT range.
  • Ekip G Hi-Touch LSIG solid-state electronic release for sophisticated protection applications.
  • Provides long-time, short-time, instantaneous and earth-fault protection.
  • Four-pole configuration for comprehensive circuit switching and protection.
  • High 120 kA ultimate short-circuit breaking capacity at 380–415 V AC.
  • Fixed mounting with front terminals for integration into low-voltage switchboards.
  • Stored-energy and lever operating mechanisms support dependable circuit-breaker operation.

Key Features

  • ABB SACE Tmax XT series.
  • XT7L M 800 circuit breaker configuration.
  • 800 A rated uninterrupted current.
  • 4-pole construction.
  • Ekip G Hi-Touch LSIG electronic release.
  • Generator-oriented electronic protection platform.
  • Long-time, short-time, instantaneous and earth-fault protection functions.
  • 120 kA Icu at 380–415 V AC.
  • 100 kA Icu at 440 V AC.
  • 50 kA Icu at 690 V AC.
  • 20 kA rated short-time withstand current.
  • Fixed installation configuration.
  • Front terminals.
  • Stored-energy and lever operating mechanisms.

Advanced Generator and High-Current Distribution Protection

Generator-fed electrical systems can require protection characteristics that differ from conventional utility-fed distribution networks. ABB's Ekip G Hi-Touch technology provides an advanced electronic protection platform suitable for generator applications, helping protect generating equipment, feeders and associated switchgear against overload, short-circuit and earth-fault conditions.

The LSIG configuration combines long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection. Together with the 800 A rating, four-pole construction and XT7L high-breaking-capacity platform, the 1SDA101810R1 provides a comprehensive solution for critical generator and high-current low-voltage distribution assemblies.

Typical Applications

  • Generator protection switchboards.
  • Standby and emergency generation systems.
  • Industrial low-voltage switchboards.
  • Main and sub-distribution panels.
  • Manufacturing and process plant power systems.
  • Infrastructure and critical power distribution.
  • High-current feeder protection and isolation.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA101810R1
EAN 8056221018548
Product type Moulded case circuit breaker
Sub-type XT7M
Performance level L
Rated uninterrupted current (Iu) 800 A
Trip unit rated current (In) 800 A
Number of poles 4
Trip unit Ekip G Hi-Touch LSIG
Release type Solid-state electronic release
Protection functions Long-time, short-time, instantaneous and earth-fault
Ultimate short-circuit breaking capacity (Icu) at 220–240 V AC 200 kA
Ultimate short-circuit breaking capacity (Icu) at 380–415 V AC 120 kA
Ultimate short-circuit breaking capacity (Icu) at 440 V AC 100 kA
Ultimate short-circuit breaking capacity (Icu) at 500 V AC 85 kA
Ultimate short-circuit breaking capacity (Icu) at 525 V AC 65 kA
Ultimate short-circuit breaking capacity (Icu) at 690 V AC 50 kA
Rated short-time withstand current (Icw) 20 kA
Mounting configuration Fixed
Terminal arrangement Front terminals
Operating mechanism Stored-energy and lever operating mechanisms
Standard IEC 60947
Product net dimensions (W × H × D) 280 × 268 × 178 mm
Product net weight 12.5 kg

Frequently Asked Questions

What is the ABB 1SDA101810R1?

The ABB 1SDA101810R1 is an XT7L M 800 SACE Tmax XT moulded case circuit breaker rated at 800 A, with four poles, fixed mounting, front terminals and an Ekip G Hi-Touch LSIG solid-state electronic release.

What protection functions does the Ekip G Hi-Touch LSIG release provide?

The Ekip G Hi-Touch LSIG release provides long-time overload, short-time delayed, instantaneous short-circuit and earth-fault protection functions.

Is the ABB 1SDA101810R1 suitable for generator protection?

Yes. The Ekip G Hi-Touch protection platform is designed for advanced generator protection applications, making the 1SDA101810R1 suitable for generator switchboards and associated power-distribution systems.

What is the rated current of the ABB XT7L M 800 1SDA101810R1?

The ABB 1SDA101810R1 has a rated uninterrupted current and Ekip G Hi-Touch LSIG release rating of 800 A.

What is the breaking capacity of the ABB 1SDA101810R1?

The breaker has an ultimate short-circuit breaking capacity of 120 kA at 380–415 V AC, 100 kA at 440 V AC and 50 kA at 690 V AC.

Does the ABB 1SDA101810R1 provide earth-fault protection?

Yes. The LSIG configuration includes earth-fault protection in addition to long-time, short-time and instantaneous protection functions.

What mounting and terminal configuration does the ABB 1SDA101810R1 use?

The breaker is supplied in a fixed four-pole configuration with front terminals and incorporates stored-energy and lever operating mechanisms.

Trusted by Electrical Distribution Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely used in industrial, commercial, infrastructure and power-generation applications where dependable high-current protection, advanced electronic trip technology and robust short-circuit performance are required.