1SDA101803R1 ABB XT7L M 1000 Ekip G Dip LS/I 1000 A 4-Pole Generator Protection Circuit Breaker

1SDA101803R1 ABB XT7L M 1000 Ekip G Dip LS/I 1000 A 4-Pole Generator Protection Circuit Breaker

ABB 1SDA101803R1 XT7L M 1000 is a 1000 A four-pole moulded-case circuit breaker with front terminals, an Ekip G Dip LS/I electronic trip unit and a 120 kA performance class for generator protection applications.

SKU: 1SDA101803R1MPN: 1SDA101803R1
Price
List Price £7,965.93 ex VAT
Your Price (ex VAT) Save 25%
£5,974.45 25% OFF
You save £1,991.48 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,974.45
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,974.45

Why Choose the ABB XT7L M 1000 Ekip G Dip LS/I 1SDA101803R1 Circuit Breaker?

The ABB XT7L M 1000 Ekip G Dip LS/I, order code 1SDA101803R1, is a high-performance moulded-case circuit breaker (MCCB) from the ABB SACE Tmax XT7 range, specifically configured for generator protection in demanding low-voltage power systems. Rated at 1000 A, this four-pole breaker combines the high-breaking-capacity XT7L M platform with an Ekip G Dip LS/I electronic trip unit.

The Ekip G Dip LS/I release provides generator-oriented long-time overload and instantaneous short-circuit protection. Its protection characteristics are designed for generator applications, helping protect generating sets and their associated distribution circuits against damaging overload and short-circuit conditions.

The 1SDA101803R1 features 4 poles and front terminals and belongs to ABB's XT7L M 120 kA class. This combination of generator-specific electronic protection and substantial short-circuit interruption capability makes it well suited to generator switchboards, standby power installations and high-current generation systems.

Key Advantages

  • Purpose-designed ABB SACE Tmax XT7 generator-protection circuit breaker.
  • 1000 A rated current for high-current generator circuits.
  • 4-pole configuration for three-phase systems incorporating the neutral conductor.
  • Ekip G Dip LS/I electronic trip unit designed for generator protection.
  • Long-time overload and instantaneous short-circuit protection.
  • 120 kA XT7L M performance class for demanding fault-current conditions.
  • Front terminals for practical switchboard integration.
  • Part of ABB's established SACE Tmax XT circuit-breaker platform.

Key Features

  • ABB SACE Tmax XT7 series.
  • XT7L M 1000 generator-protection configuration.
  • 1000 A rated current.
  • 4-pole design.
  • Ekip G Dip LS/I electronic protection release.
  • Generator-oriented protection characteristics.
  • Long-time overload protection.
  • Instantaneous short-circuit protection.
  • 120 kA performance class.
  • Front terminal connections.
  • Designed for high-current low-voltage generator systems.

Reliable Generator Protection for High-Current Power Systems

Generator circuits require protection characteristics suited to the operating behaviour and fault-current capability of generating sources. ABB's Ekip G protection releases are designed for generator applications, providing electronic protection for generating sets and their associated low-voltage distribution systems.

The Ekip G Dip LS/I release combines generator-oriented long-time overload and instantaneous short-circuit protection with the high interruption performance of the 120 kA XT7L M platform. This makes the ABB 1SDA101803R1 suitable for generator switchboards and critical-power installations where dependable protection and high short-circuit performance are required.

Typical Applications

  • Generator protection switchboards.
  • Standby and emergency power systems.
  • Industrial generator installations.
  • Critical-power distribution systems.
  • High-current generator feeders.
  • Commercial and infrastructure generating systems.

Technical Specifications

Series SACE Tmax XT7
Order code 1SDA101803R1
Product type Moulded-case circuit breaker
Application Generator protection
Frame XT7L M
Rated current 1000 A
Number of poles 4
Trip unit Ekip G Dip LS/I
Protection functions Long-time and instantaneous
Performance class 120 kA
Terminal arrangement Front terminals

Frequently Asked Questions

What is the ABB 1SDA101803R1 used for?

The ABB 1SDA101803R1 is a 1000 A four-pole moulded-case circuit breaker specifically configured for generator protection in high-current low-voltage power systems.

What trip unit is fitted to the ABB XT7L M 1000?

This circuit breaker is fitted with an ABB Ekip G Dip LS/I electronic trip unit designed for generator-protection applications.

What protection functions does the Ekip G Dip LS/I provide?

The Ekip G Dip LS/I provides long-time overload and instantaneous short-circuit protection with characteristics intended for generator applications.

What is the performance class of ABB 1SDA101803R1?

The XT7L M configuration belongs to ABB's 120 kA performance class, providing substantial short-circuit interruption capability for demanding generator installations.

How is the ABB XT7L M 1000 connected?

The 1SDA101803R1 is a 4-pole circuit breaker with front terminals, designed for integration into generator switchboards and high-current low-voltage distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers and Ekip G protection releases provide dependable generator protection for demanding industrial, commercial and infrastructure power systems where high-current performance and reliable fault protection are essential.