1SDA101790R1 ABB XT7L M 800 Ekip Touch Measuring LSIG 800A 4P Circuit Breaker

1SDA101790R1 ABB XT7L M 800 Ekip Touch Measuring LSIG 800A 4P Circuit Breaker

ABB 1SDA101790R1 XT7L M 800 is an 800 A four-pole moulded case circuit breaker with an Ekip Touch Measuring LSIG electronic trip unit, integrated electrical measurement, front terminals and a 120 kA breaking-capacity class for advanced low-voltage power-distribution protection.

SKU: 1SDA101790R1MPN: 1SDA101790R1
Price
List Price £9,228.27 ex VAT
Your Price (ex VAT) Save 25%
£6,921.20 25% OFF
You save £2,307.07 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,921.20
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,921.20

Why Choose the ABB XT7L M 800 Ekip Touch Measuring LSIG 1SDA101790R1 Circuit Breaker?

The ABB 1SDA101790R1 is a high-performance SACE Tmax XT7L M moulded case circuit breaker (MCCB) designed for advanced protection, switching and electrical measurement in demanding low-voltage power distribution systems. This four-pole circuit breaker combines an 800 A rated current with ABB’s Ekip Touch Measuring LSIG electronic trip unit, providing comprehensive protection against overload, short-circuit and ground-fault conditions.

As part of the ABB SACE Tmax XT range, the XT7L M 800 is engineered for industrial, commercial and infrastructure installations requiring high short-circuit interruption performance and advanced electronic protection. The Ekip Touch Measuring LSIG release combines long-time, short-time, instantaneous and ground-fault protection with integrated electrical measurement functionality, supporting both circuit protection and power-system monitoring.

The 1SDA101790R1 features a four-pole configuration with front terminals and ABB’s XT7L high-breaking-capacity performance level. The XT7L M platform provides a 120 kA breaking-capacity class, making it particularly suitable for main distribution boards, major feeders and installations where substantial prospective short-circuit currents may occur.

Key Advantages

  • High-performance 800 A moulded case circuit breaker for demanding low-voltage distribution systems.
  • Advanced Ekip Touch Measuring LSIG electronic trip unit combines protection with electrical measurement.
  • Long-time, short-time, instantaneous and ground-fault protection functions.
  • Integrated measurement functionality supports monitoring of electrical system parameters.
  • Four-pole configuration for three-phase systems requiring neutral switching.
  • High 120 kA breaking-capacity class for installations with substantial prospective fault currents.
  • Front-terminal configuration for practical integration into low-voltage switchboards.
  • Advanced electronic protection supports selective and coordinated power-distribution systems.

Key Features

  • ABB SACE Tmax XT7L M moulded case circuit breaker.
  • 800 A rated current.
  • Four-pole configuration.
  • XT7 M platform.
  • Ekip Touch Measuring LSIG electronic trip unit.
  • Integrated electrical measurement functionality.
  • Long-time overload protection.
  • Short-time selective short-circuit protection.
  • Instantaneous short-circuit protection.
  • Ground-fault protection.
  • L high-breaking-capacity performance level.
  • 120 kA breaking-capacity class.
  • Front main-circuit terminals.
  • Designed for advanced high-current low-voltage power distribution.

Advanced Protection and Measurement for Power Distribution

The ABB Tmax XT7L M platform is designed for high-current low-voltage installations where substantial prospective short-circuit currents demand powerful interruption capability. With its 800 A rated current and 120 kA breaking-capacity class, the 1SDA101790R1 is well suited to major feeders, incoming supplies and distribution circuits requiring robust protection.

The Ekip Touch Measuring LSIG electronic trip unit combines long-time, short-time, instantaneous and ground-fault protection with integrated electrical measurement functionality. This combination allows the circuit breaker to protect against a broad range of abnormal current conditions while supporting monitoring and management of sophisticated industrial and commercial power-distribution systems.

Typical Applications

  • Main low-voltage electrical distribution boards.
  • Industrial switchboards and power distribution assemblies.
  • High-current incoming and feeder protection.
  • Transformer secondary distribution.
  • Manufacturing plants and process facilities.
  • Commercial and infrastructure electrical installations.
  • Power systems requiring integrated electrical measurement.
  • Installations requiring four-pole switching and comprehensive LSIG protection.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA101790R1
GTIN / EAN 8056221018340
Product type Moulded case circuit breaker
Frame XT7 M
Performance level XT7L
Rated current 800 A
Number of poles 4
Trip unit Ekip Touch Measuring LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and ground fault
Measurement functionality Integrated
Short-circuit performance level L
Breaking-capacity class 120 kA
Terminal connection Front terminals
Product weight 14 kg
Application Low-voltage power distribution, circuit protection and electrical measurement

Frequently Asked Questions

What is the ABB 1SDA101790R1 used for?

The ABB 1SDA101790R1 is an 800 A four-pole moulded case circuit breaker designed for advanced protection, switching and electrical measurement in demanding low-voltage power-distribution systems.

What trip unit is fitted to the ABB 1SDA101790R1?

The breaker is fitted with an Ekip Touch Measuring LSIG electronic trip unit, providing long-time, short-time, instantaneous and ground-fault protection together with integrated electrical measurement functionality.

What is the breaking-capacity class of the ABB XT7L M 800?

The ABB XT7L M platform has a 120 kA breaking-capacity class, providing high interruption performance for demanding low-voltage installations with substantial prospective short-circuit currents.

What does LSIG protection mean on the ABB 1SDA101790R1?

LSIG identifies the breaker’s principal protection functions: long-time (L), short-time (S), instantaneous (I) and ground-fault (G) protection, providing comprehensive electronic protection for the connected distribution circuit.

How is the ABB XT7L M 800 1SDA101790R1 connected?

The 1SDA101790R1 is a four-pole breaker with front terminals, identified by the 4pFF configuration, for integration into low-voltage switchboards and power-distribution assemblies.

Trusted for Advanced Power Distribution

ABB SACE Tmax XT circuit breakers combine high short-circuit interruption performance with advanced Ekip electronic protection and measurement technology, providing dependable protection and monitoring for industrial, commercial and infrastructure power-distribution systems.