1SDA101717R1 ABB XT7H M 1600 Ekip Dip LSI 1600A 4-Pole MCCB

1SDA101717R1 ABB XT7H M 1600 Ekip Dip LSI 1600A 4-Pole MCCB

ABB 1SDA101717R1 XT7H M 1600 is a 1600 A four-pole fixed moulded case circuit breaker with Ekip Dip LSI electronic protection, front terminals and H-class 70 kA interruption performance for demanding low-voltage AC power distribution.

SKU: 1SDA101717R1MPN: 1SDA101717R1
Price
List Price £8,692.32 ex VAT
Your Price (ex VAT) Save 25%
£6,519.24 25% OFF
You save £2,173.08 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,519.24
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,519.24

Why Choose the ABB XT7H M 1600 Ekip Dip LSI 1SDA101717R1 Circuit Breaker?

The ABB 1SDA101717R1, designated XT7H M 1600 Ekip Dip LSI In=1600A 4p F F, is a high-performance four-pole moulded case circuit breaker (MCCB) designed for protection and switching of high-current low-voltage AC power distribution systems. As part of the ABB SACE Tmax XT7 range, it combines a 1600 A rated current with an Ekip Dip LSI solid-state trip unit, H-class interruption performance and a stored-energy operating mechanism.

This fixed circuit breaker incorporates the ABB Ekip Dip LSI electronic trip unit, providing long-time overload (L), short-time short-circuit (S) and instantaneous short-circuit (I) protection. The electronic release provides dependable circuit protection and coordination for industrial distribution systems, while the absence of integrated earth-fault protection makes the LSI configuration suitable where dedicated L, S and I protection functions are required.

With a rated uninterrupted current of 1600 A, four-pole construction, front terminals and a rated voltage of 690 V AC, the 1SDA101717R1 is well suited to industrial switchboards, main distribution panels, transformer and generator circuits and other high-current installations. The XT7H performance level provides 70 kA breaking capacity, supporting dependable fault interruption in demanding low-voltage networks.

Key Advantages

  • High-performance ABB SACE Tmax XT7 moulded case circuit breaker.
  • 1600 A rated current for high-capacity low-voltage power distribution.
  • Four-pole configuration for three-phase systems with neutral.
  • H-class 70 kA interruption performance for demanding fault levels.
  • Ekip Dip LSI electronic trip unit for reliable circuit protection.
  • LSI functionality provides long-time, short-time and instantaneous protection.
  • Fixed construction with front terminals for switchboard integration.
  • Stored-energy operating mechanism for dependable circuit-breaker switching.

Key Features

  • ABB SACE Tmax XT7H M series.
  • 1600 A rated uninterrupted current.
  • Four-pole moulded case circuit breaker.
  • Ekip Dip LSI solid-state release.
  • Long-time overload (L) protection.
  • Short-time short-circuit (S) protection.
  • Instantaneous short-circuit (I) protection.
  • H-class high breaking capacity.
  • 70 kA interruption rating.
  • 690 V AC rated voltage.
  • Fixed installation with front main-circuit connections.
  • Bolted main-circuit connection.
  • IP20 protection rating.
  • Stored-energy operating mechanism.
  • Optional motor drive for automated operating applications.

Reliable High-Capacity Circuit Protection

Moulded case circuit breakers such as the ABB Tmax XT7 protect low-voltage electrical distribution systems against overloads and short circuits while also providing dependable switching and isolation. The XT7H's high interruption capability enables substantial prospective fault currents to be interrupted safely, helping protect cables, switchgear and connected equipment in demanding industrial installations.

The Ekip Dip LSI trip unit combines electronic long-time, short-time and instantaneous protection with the high breaking performance of the XT7H platform. Together with its 1600 A current rating, four-pole configuration and stored-energy operating mechanism, the 1SDA101717R1 provides a robust solution for high-capacity low-voltage switchboards and power distribution systems.

Typical Applications

  • Industrial low-voltage switchboards and distribution panels.
  • Main incoming and feeder circuit protection.
  • Transformer and generator protection circuits.
  • Manufacturing and process industry power distribution.
  • Commercial and infrastructure electrical installations.
  • Data centre and critical power distribution systems.
  • Large machinery and plant electrical systems.
  • High-fault-level low-voltage distribution networks.

Technical Specifications

Series SACE Tmax XT
Frame size XT7M
ABB order code 1SDA101717R1
Product type Moulded case circuit breaker (MCCB)
Rated current 1600 A
Rated uninterrupted current (Iu) 1600 A
Number of poles 4
Current type AC
Trip unit Ekip Dip LSI
Release type Electronic / solid-state
Protection functions L, S and I
Integrated earth-fault protection No
Interruption rating H
Breaking capacity 70 kA
Rated voltage 690 V AC
Installation version Fixed
Main circuit connection Bolted connection
Main circuit connection position Front
Operating mechanism Stored-energy mechanism
Control element Toggle
Motor drive Optional
Protection rating IP20
DIN rail mounting No
Standard IEC
Weight 15.5 kg
Country of origin Italy
EAN / UPC 8056221017619

Frequently Asked Questions

What is the ABB 1SDA101717R1 used for?

The ABB 1SDA101717R1 is a 1600 A four-pole moulded case circuit breaker used to protect and switch high-current AC electrical distribution circuits in industrial, commercial and infrastructure installations.

What protection unit is fitted to the ABB 1SDA101717R1?

The circuit breaker is fitted with an Ekip Dip LSI electronic trip unit, providing long-time overload, short-time short-circuit and instantaneous short-circuit protection.

What is the breaking performance of the ABB XT7H M 1600?

The XT7H M 1600 has an H-class 70 kA interruption rating, making it suitable for demanding low-voltage distribution systems with high prospective fault currents.

How many poles does the ABB 1SDA101717R1 have?

The 1SDA101717R1 is a four-pole circuit breaker, making it suitable for three-phase electrical distribution systems where switching and protection of the neutral are required.

How is the ABB XT7H M 1600 installed?

This model is a fixed circuit breaker with front bolted connections and a stored-energy operating mechanism, designed for integration into low-voltage switchboards and electrical distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded case circuit breakers are widely used by panel builders, electrical engineers and industrial operators for dependable circuit protection, high short-circuit interruption capability and reliable low-voltage power distribution.