1SDA101691R1 ABB XT7S M 1000 Ekip G Dip LS/I 1000A 4-Pole Circuit Breaker

1SDA101691R1 ABB XT7S M 1000 Ekip G Dip LS/I 1000A 4-Pole Circuit Breaker

ABB 1SDA101691R1 is a 1000 A four-pole SACE Tmax XT7S M fixed moulded case circuit breaker with front terminals, stored-energy operation and an Ekip G Dip LS/I electronic protection release.

SKU: 1SDA101691R1MPN: 1SDA101691R1
Price
List Price £4,459.21 ex VAT
Your Price (ex VAT) Save 25%
£3,344.41 25% OFF
You save £1,114.80 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,344.41
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,344.41

Why Choose the ABB XT7S M 1000 Ekip G Dip LS/I 1SDA101691R1 Circuit Breaker?

The ABB 1SDA101691R1 is a high-performance SACE Tmax XT7S M moulded case circuit breaker designed for dependable protection and switching in demanding low-voltage power distribution and generator applications. Rated at 1000 A, this four-pole fixed circuit breaker combines the robust XT7 M stored-energy platform with an Ekip G Dip LS/I electronic trip unit.

The Ekip G Dip LS/I release provides adjustable long-time overload protection together with selectable short-time delayed or instantaneous short-circuit protection. Settings are made using front-mounted dip switches, providing a straightforward method of adapting the protection characteristics to the requirements of the electrical installation.

This four-pole XT7S M model is designed for fixed installation and features front terminals for integration into industrial switchboards. It has a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, providing robust fault protection for high-current distribution systems.

Key Advantages

  • High-current 1000 A moulded case circuit breaker for demanding electrical distribution.
  • Ekip G Dip LS/I electronic trip unit provides configurable overload and short-circuit protection.
  • Four-pole configuration supports switching and protection of three-phase systems with neutral.
  • 50 kA ultimate short-circuit breaking capacity at 415 V AC.
  • Rated operational voltage up to 690 V AC.
  • Fixed installation with front terminals simplifies integration into low-voltage switchboards.

Key Features

  • ABB SACE Tmax XT7S M series.
  • 1000 A rated uninterrupted current.
  • 4-pole construction.
  • Ekip G Dip LS/I electronic protection release.
  • Long-time overload protection.
  • Selectable short-time delayed or instantaneous short-circuit protection.
  • Manual protection settings using front-mounted dip switches.
  • 50 kA Icu at 415 V AC.
  • Fixed mounting with front terminals.
  • Stored-energy operating mechanism.
  • Optional motor drive capability.
  • IP20 degree of protection.

Reliable Protection for Generator and Power Distribution Systems

Moulded case circuit breakers such as the ABB Tmax XT7S M protect electrical installations against overload and short-circuit conditions while providing dependable switching and isolation. Electronic trip technology allows protection characteristics to be configured more precisely for the installation, supporting selective coordination and continuity of electrical service.

The Ekip G Dip LS/I release combines adjustable long-time overload protection with selectable delayed or instantaneous short-circuit protection. Together with the XT7S M stored-energy mechanism, four-pole configuration and optional motor drive capability, the 1SDA101691R1 provides a flexible protection solution for generator systems, industrial switchboards and high-current power distribution.

Typical Applications

  • Generator protection and generator distribution systems.
  • Industrial low-voltage switchboards.
  • Main incoming and outgoing feeder protection.
  • Manufacturing and process-industry electrical systems.
  • Commercial and infrastructure power distribution.
  • High-current three-phase systems requiring four-pole switching.

Technical Specifications

Series SACE Tmax XT
ABB order code 1SDA101691R1
Product type Moulded case circuit breaker
Frame / family XT7 M
Breaking-capacity version XT7S
Rated uninterrupted current 1000 A
Number of poles 4
Trip unit Ekip G Dip LS/I
Release type Electronic
Protection functions Long-time overload and selectable short-time / instantaneous short-circuit protection
Integrated earth-fault protection No
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Ultimate short-circuit breaking capacity at 415 V AC 50 kA
Service short-circuit breaking capacity at 415 V AC 50 kA
Rated short-time withstand current 20 kA
Installation Fixed
Main circuit connection Front, bolt connection
Operating mechanism Stored energy
Motor drive Optional
Protection rating IP20
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA101691R1 used for?

The ABB 1SDA101691R1 is a 1000 A four-pole moulded case circuit breaker designed for protection, switching and isolation in generator and low-voltage power distribution systems.

What protection unit is fitted to the ABB 1SDA101691R1?

This circuit breaker is fitted with an Ekip G Dip LS/I electronic trip unit providing long-time overload protection together with selectable short-time delayed or instantaneous short-circuit protection.

What is the rated current of this circuit breaker?

The XT7S M 1000 has a rated uninterrupted current of 1000 A.

What is the breaking capacity of the ABB 1SDA101691R1?

The XT7S M version has an ultimate short-circuit breaking capacity of 50 kA at 415 V AC.

How is the ABB 1SDA101691R1 installed?

The 1SDA101691R1 is a four-pole fixed circuit breaker with front bolt connections and a stored-energy operating mechanism, with optional motor drive capability.