1SDA101539R1 ABB XT7L M 1000 Ekip G Dip LS/I 1000 A 3-Pole Circuit Breaker

1SDA101539R1 ABB XT7L M 1000 Ekip G Dip LS/I 1000 A 3-Pole Circuit Breaker

ABB 1SDA101539R1 XT7L M 1000 is a fixed three-pole 1000 A SACE Tmax XT generator-protection moulded-case circuit breaker with front terminals, 120 kA interruption performance and an Ekip G Dip LS/I electronic trip unit.

SKU: 1SDA101539R1MPN: 1SDA101539R1
Price
List Price £6,322.24 ex VAT
Your Price (ex VAT) Save 25%
£4,741.68 25% OFF
You save £1,580.56 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,741.68
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,741.68

Why Choose the ABB XT7L M 1000 Ekip G Dip LS/I Circuit Breaker?

The ABB XT7L M 1000 Ekip G Dip LS/I, order code 1SDA101539R1, is a high-performance three-pole moulded-case circuit breaker from the ABB SACE Tmax XT7 range, specifically configured for generator protection and demanding low-voltage power-distribution applications. It combines a 1000 A rated current with ABB’s Ekip G Dip LS/I electronic trip unit.

The Ekip G Dip LS/I release belongs to ABB’s generator-protection range and provides electronic protection against overload and short-circuit conditions. Its generator-oriented protection characteristics make the breaker suitable for safeguarding generating sets, generator feeders and associated distribution equipment where dependable fault clearing and coordinated protection are required.

The XT7L M configuration features a fixed three-pole construction with front terminals and ABB’s stored-energy operating mechanism. The L performance version provides a 120 kA ultimate short-circuit breaking capacity at 380/400 V AC, delivering the high interruption capability required in generator switchboards and industrial installations with substantial prospective fault currents.

Key Advantages

  • ABB SACE Tmax XT7 circuit breaker engineered for generator protection.
  • 1000 A rated current for high-current generator and distribution applications.
  • Ekip G Dip LS/I electronic trip unit.
  • Electronic overload and short-circuit protection.
  • 120 kA ultimate short-circuit breaking capacity at 380/400 V AC.
  • Three-pole fixed construction with front terminals.
  • Stored-energy operating mechanism for dependable high-current switching.
  • Suitable for generator switchboards, standby-power systems and industrial distribution assemblies.

Key Features

  • ABB SACE Tmax XT7L M series.
  • 1000 A rated current.
  • Ekip G Dip LS/I electronic protection release.
  • Designed specifically for generator-protection applications.
  • Electronic overload and short-circuit protection.
  • Overload-release adjustment range: 400–1000 A.
  • Short-circuit release adjustment range: 1000–10000 A.
  • XT7M frame.
  • L interruption-performance level.
  • Three-pole circuit breaker.
  • Fixed mounting configuration.
  • Front main-circuit terminals.

Reliable Protection for Generators and Power Distribution

Generator circuits require protection characteristics suited to the electrical behaviour of generating sets as well as dependable interruption of overload and short-circuit conditions. The ABB Ekip G family is designed for generator-protection duties, allowing the SACE Tmax XT7 platform to protect generators, feeders, switchgear and associated distribution equipment in demanding low-voltage installations.

With its 1000 A rating, Ekip G Dip LS/I electronic release and 120 kA XT7L interruption performance, the 1SDA101539R1 is particularly suited to generator switchboards and installations with high prospective fault currents. Its fixed three-pole construction and front terminals support straightforward integration into industrial, commercial and infrastructure power-distribution assemblies.

Typical Applications

  • Generator protection and generator switchboards.
  • Standby and emergency generating systems.
  • Generator-fed low-voltage distribution networks.
  • Industrial power-generation installations.
  • High-current generator feeder protection.
  • Critical and infrastructure power systems.
  • Manufacturing and process-industry electrical systems.
  • OEM generator and switchgear assemblies.

Technical Specifications

Series SACE Tmax XT7
Order code / MPN 1SDA101539R1
Product type Generator-protection moulded-case circuit breaker
Frame XT7M
Performance level L
Rated current 1000 A
Number of poles 3
Trip unit Ekip G Dip LS/I
Release type Electronic generator-protection release
Overload-release adjustment 400–1000 A
Short-circuit release adjustment 1000–10000 A
Ultimate short-circuit breaking capacity at 380/400 V AC 120 kA
Application Generator protection
Mounting configuration Fixed
Main-circuit connection position Front
Operating mechanism Stored-energy operating mechanism
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA101539R1 used for?

The ABB 1SDA101539R1 is a SACE Tmax XT7L M moulded-case circuit breaker equipped with an Ekip G Dip LS/I electronic release and designed for generator protection and high-current low-voltage switching.

What is the rated current of the ABB XT7L M 1SDA101539R1?

The 1SDA101539R1 has a rated current of 1000 A.

What trip unit is fitted to the ABB 1SDA101539R1?

The breaker is equipped with an Ekip G Dip LS/I electronic trip unit from ABB’s generator-protection range, providing electronic overload and short-circuit protection.

What is the breaking capacity of the ABB XT7L M 1SDA101539R1?

The XT7L M version provides an ultimate short-circuit breaking capacity of 120 kA at 380/400 V AC, making it suitable for demanding systems with high prospective fault currents.

How is the ABB 1SDA101539R1 configured for installation?

The 1SDA101539R1 is a three-pole fixed circuit breaker with front main-circuit terminals and a stored-energy operating mechanism.

Trusted by Electrical Engineers Worldwide

ABB SACE Tmax XT circuit breakers are widely used in generator, industrial and critical power-distribution systems where dependable protection, high short-circuit performance and robust high-current switching are required.