1SDA101474R1 ABB XT7H M 800 Ekip G Dip LS/I 800 A 3-Pole Circuit Breaker

1SDA101474R1 ABB XT7H M 800 Ekip G Dip LS/I 800 A 3-Pole Circuit Breaker

ABB 1SDA101474R1 XT7H M 800 is an 800 A three-pole fixed moulded-case circuit breaker with front terminals, a stored-energy operating mechanism and an Ekip G Dip LS/I electronic release for generator and low-voltage installation protection.

SKU: 1SDA101474R1MPN: 1SDA101474R1
Price
List Price £3,389.19 ex VAT
Your Price (ex VAT) Save 25%
£2,541.89 25% OFF
You save £847.30 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,541.89
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,541.89

Why Choose the ABB XT7H M 800 Ekip G Dip LS/I 1SDA101474R1 Circuit Breaker?

The ABB 1SDA101474R1 is a high-performance SACE Tmax XT7H M moulded-case circuit breaker (MCCB) specifically configured for generator and installation protection in demanding low-voltage AC systems. Rated at 800 A, this three-pole circuit breaker combines ABB’s XT7 platform with an Ekip G Dip LS/I solid-state electronic trip unit.

The Ekip G Dip LS/I release is designed for generator protection and provides long-time overload protection together with short-circuit protection functions. Its adjustable electronic protection characteristics make the breaker suitable for applications where generator operating conditions require carefully coordinated protection against sustained overloads and fault currents.

The XT7H M 800 has a rated uninterrupted current of 800 A, a rated operational voltage of 690 V AC and an H short-circuit performance level. It provides an ultimate and service short-circuit breaking capacity of 70 kA at 415 V AC, while its three-pole fixed construction, front terminals and stored-energy operating mechanism support robust integration into generator switchboards and industrial power distribution assemblies.

Key Advantages

  • ABB SACE Tmax XT7H circuit breaker engineered for generator, transformer and installation protection.
  • 800 A rated current for demanding three-phase low-voltage AC systems.
  • Ekip G Dip LS/I electronic trip unit specifically suited to generator protection applications.
  • Adjustable electronic protection supports effective overload and short-circuit coordination.
  • 70 kA Icu and Ics at 415 V AC for high fault-current applications.
  • Rated operational voltage up to 690 V AC.
  • Three-pole fixed configuration with front terminals for straightforward switchboard integration.
  • Stored-energy operating mechanism provides dependable circuit breaker switching.

Key Features

  • ABB SACE Tmax XT7H M series.
  • 800 A rated current (In).
  • 800 A rated uninterrupted current (Iu).
  • Three-pole construction.
  • Ekip G Dip LS/I solid-state electronic release.
  • Designed for generator protection.
  • H short-circuit performance level.
  • 70 kA breaking capacity at 415 V AC.
  • Operational voltage up to 690 V AC.
  • Fixed mounting configuration.
  • Front terminal connections.
  • Stored-energy operating mechanism.

Reliable Generator and Power Distribution Protection

Generator circuits have protection requirements that can differ from conventional distribution feeders because available short-circuit currents and permissible overload characteristics depend on the generator and installation design. The ABB Ekip G Dip LS/I release is intended for generator protection applications, combining adjustable electronic protection with the high-current switching capability of the Tmax XT7 platform.

With its 800 A rating, 70 kA breaking capacity at 415 V AC, 20 kA short-time withstand current and operation at voltages up to 690 V AC, the 1SDA101474R1 provides a robust solution for generator switchboards and demanding industrial power systems. Its fixed three-pole construction and front terminals also simplify integration into purpose-built low-voltage distribution assemblies.

Typical Applications

  • Low-voltage generator protection systems.
  • Generator switchboards and control panels.
  • Standby and emergency power generation systems.
  • Industrial generating installations.
  • Transformer and installation protection.
  • Main and sub-main low-voltage distribution boards.
  • Industrial switchboards and power distribution assemblies.
  • Three-phase high-current AC distribution networks.

Technical Specifications

Series SACE Tmax XT
Frame XT7
Sub-type XT7M
Order code / SKU 1SDA101474R1
ABB product group T-Max XT 250 Range
Product type Moulded-case circuit breaker (MCCB)
Rated current (In) 800 A
Rated uninterrupted current (Iu) 800 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Number of poles 3
Current type AC
Trip unit Ekip G Dip LS/I
Release type Solid-state electronic
Short-circuit performance level H
Rated ultimate breaking capacity (Icu) at 415 V AC 70 kA
Rated service breaking capacity (Ics) at 415 V AC 70 kA
Rated ultimate breaking capacity (Icu) at 690 V AC 42 kA
Rated service breaking capacity (Ics) at 690 V AC 42 kA
Rated short-time withstand current (Icw) 20 kA
Overload release adjustment range 320–800 A
Mounting configuration Fixed
Terminal type Front terminals
Operating mechanism Stored energy
Power loss at rated operating conditions 24 W per pole
Mechanical durability 20,000 cycles
Electrical durability 3,000 cycles
Dimensions (W × H × D) 210 × 268 × 178 mm
Net weight 11 kg
Standard IEC 60947
EAN 8056221012881
Customs tariff number 85362090
Application Generator, transformer and installation protection

Frequently Asked Questions

What is the ABB 1SDA101474R1 used for?

The ABB 1SDA101474R1 is an 800 A three-pole moulded-case circuit breaker configured with an Ekip G Dip LS/I electronic release for generator, transformer and low-voltage installation protection.

What is the rated current of the XT7H M 800?

The XT7H M 800 has a rated current and rated uninterrupted current of 800 A, making it suitable for demanding high-current generator and low-voltage distribution applications.

What is the Ekip G Dip LS/I trip unit designed for?

The Ekip G Dip LS/I is an electronic protection release designed for generator protection, providing adjustable overload and short-circuit protection characteristics suitable for generator-fed electrical systems.

What is the breaking capacity of the ABB 1SDA101474R1?

The XT7H M 800 has rated ultimate and service short-circuit breaking capacities of 70 kA at 415 V AC and 42 kA at 690 V AC.

How is the ABB XT7H M 800 installed?

The 1SDA101474R1 is supplied as a fixed three-pole circuit breaker with front terminals and a stored-energy operating mechanism for integration into generator switchboards and low-voltage power distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT moulded-case circuit breakers are widely used by electrical engineers, panel builders and industrial operators for dependable generator, transformer and installation protection in demanding low-voltage power systems.