Why Choose the ABB XT7S M 1600 Ekip G Dip LS/I Circuit Breaker?

The ABB XT7S M 1600 Ekip G Dip LS/I, order code 1SDA101413R1, is a high-current SACE Tmax XT moulded-case circuit breaker designed for generator protection, switching and dependable fault protection in demanding low-voltage electrical systems. This fixed three-pole breaker combines the XT7S M platform with an Ekip G Dip LS/I electronic trip unit and a rated current of 1600 A.

As part of the ABB SACE Tmax XT family, the 1SDA101413R1 provides electronic protection specifically suited to generator and high-current distribution applications. Its Ekip G Dip LS/I solid-state release provides long-time overload protection together with selectable short-time or instantaneous short-circuit protection, enabling effective coordination with the electrical system being protected.

The XT7S M 1600 is supplied in a fixed three-pole configuration with front terminals and incorporates a stored-energy operating mechanism. It has a rated operational voltage of 690 V AC, rated insulation voltage of 1000 V and an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, making it a robust solution for high-capacity industrial and generator switchboards.

Key Advantages

  • High-current 1600 A SACE Tmax XT moulded-case circuit breaker.
  • Ekip G Dip LS/I electronic trip unit designed for generator protection applications.
  • Long-time overload protection with selectable short-time or instantaneous short-circuit protection.
  • 50 kA ultimate and service breaking capacity at 415 V AC.
  • Three-pole fixed configuration for three-phase electrical systems.
  • Front terminals support practical integration into switchboards.
  • Stored-energy operating mechanism provides dependable switching operation.

Key Features

  • ABB SACE Tmax XT series.
  • XT7S M 1600 configuration.
  • 1600 A rated current.
  • Three-pole construction.
  • Ekip G Dip LS/I solid-state electronic release.
  • LS/I protection for overload and selectable short-time or instantaneous short-circuit protection.
  • 690 V AC rated operational voltage.
  • 1000 V rated insulation voltage.
  • 8 kV rated impulse withstand voltage.
  • 50 kA breaking capacity at 415 V AC.
  • 20 kA rated short-time withstand current.
  • Fixed mounting with front terminals.

Reliable Protection for Generator and High-Current Distribution Systems

Moulded-case circuit breakers used for generator protection must provide dependable overload and short-circuit protection while accommodating the operating characteristics of generating equipment. The ABB Ekip G protection platform is developed for generator applications, helping protect generators and their associated electrical distribution circuits against damaging overcurrent conditions.

The Ekip G Dip LS/I release combines long-time overload protection with selectable short-time or instantaneous short-circuit protection. Together with the 1600 A XT7S M platform, 50 kA breaking capacity and stored-energy operating mechanism, the 1SDA101413R1 provides a robust protection and switching solution for generator switchboards and high-capacity low-voltage power systems.

Typical Applications

  • Low-voltage generator protection systems.
  • Generator switchboards and control panels.
  • Main and sub-main electrical distribution boards.
  • Industrial power-generation installations.
  • High-current feeder protection.
  • Manufacturing, infrastructure and process-industry power systems.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA101413R1
EAN 8056221012317
Product type Moulded-case circuit breaker
Frame size XT7M
Rated current 1600 A
Rated uninterrupted current 1600 A
Number of poles 3
Trip unit Ekip G Dip LS/I
Release type Solid-state electronic release
Protection functions Long-time and selectable short-time / instantaneous short-circuit protection
Rated operational voltage 690 V AC
Rated insulation voltage 1000 V
Rated impulse withstand voltage 8 kV
Ultimate breaking capacity at 415 V AC 50 kA
Service breaking capacity at 415 V AC 50 kA
Rated short-time withstand current 20 kA
Short-circuit performance level S
Installation Fixed
Terminal arrangement Front terminals
Operating mechanism Stored-energy mechanism
Standard IEC 60947-2

Frequently Asked Questions

What is the ABB 1SDA101413R1?

The ABB 1SDA101413R1 is an XT7S M 1600 fixed three-pole SACE Tmax XT moulded-case circuit breaker with a 1600 A Ekip G Dip LS/I solid-state electronic trip unit.

What is the rated current of the ABB XT7S M 1600?

This circuit breaker has a rated current of 1600 A, making it suitable for high-current generator and low-voltage distribution applications.

What protection does the Ekip G Dip LS/I trip unit provide?

The Ekip G Dip LS/I release provides long-time overload protection together with selectable short-time or instantaneous short-circuit protection.

What is the breaking capacity of the ABB 1SDA101413R1?

The XT7S M 1600 has an ultimate and service short-circuit breaking capacity of 50 kA at 415 V AC.

How is the ABB 1SDA101413R1 installed?

The breaker uses a fixed three-pole configuration with front terminals and incorporates a stored-energy operating mechanism for integration into suitable switchboards.