1SDA101401R1 ABB XT7S M 1600 Ekip Hi-Touch LSIG 1600 A 3-Pole Circuit Breaker

1SDA101401R1 ABB XT7S M 1600 Ekip Hi-Touch LSIG 1600 A 3-Pole Circuit Breaker

ABB 1SDA101401R1 XT7S M 1600 is a 1600 A three-pole fixed moulded-case circuit breaker with front terminals, a stored-energy operating mechanism and an Ekip Hi-Touch LSIG electronic trip unit for advanced low-voltage power distribution protection.

SKU: 1SDA101401R1MPN: 1SDA101401R1
Price
List Price £10,765.83 ex VAT
Your Price (ex VAT) Save 25%
£8,074.37 25% OFF
You save £2,691.46 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £8,074.37
Trade pricing is personalised to your account

Manufacturer Lead Time

£8,074.37

Why Choose the ABB XT7S M 1600 Ekip Hi-Touch LSIG 1SDA101401R1 Circuit Breaker?

The ABB 1SDA101401R1 is a high-performance SACE Tmax XT7S M moulded-case circuit breaker (MCCB) designed for reliable protection and switching of demanding low-voltage electrical distribution systems. Rated at 1600 A, this three-pole circuit breaker combines ABB’s XT7M platform with the advanced Ekip Hi-Touch LSIG electronic trip unit for comprehensive protection against overloads, short circuits and ground faults.

As part of the ABB SACE Tmax XT range, the XT7S M is engineered for industrial, commercial and infrastructure power distribution applications requiring high current capacity and sophisticated electronic protection. The Ekip Hi-Touch LSIG release provides long-time, short-time, instantaneous and ground-fault protection, enabling accurate protection settings and effective coordination within complex low-voltage installations.

The XT7S M 1600 has a rated current of 1600 A, a rated operational voltage of up to 690 V AC and an ultimate short-circuit breaking capacity of 50 kA at 415 V AC. Its three-pole fixed configuration with front terminals and stored-energy operating mechanism make it particularly suitable for main switchboards, high-current feeders and critical industrial power distribution systems.

Key Advantages

  • High-performance ABB SACE Tmax XT7 moulded-case circuit breaker for demanding low-voltage distribution.
  • 1600 A rated current for high-current industrial and commercial electrical systems.
  • Advanced Ekip Hi-Touch LSIG electronic trip unit for comprehensive circuit protection.
  • LSIG functionality provides long-time, short-time, instantaneous and ground-fault protection.
  • 50 kA ultimate breaking capacity at 415 V AC for installations with substantial prospective fault currents.
  • Three-pole fixed configuration designed for three-phase power distribution systems.
  • Front terminals support straightforward switchboard and distribution-panel integration.
  • Stored-energy operating mechanism provides dependable circuit breaker operation.

Key Features

  • ABB SACE Tmax XT7S M series.
  • 1600 A rated current (In).
  • Three-pole construction.
  • Ekip Hi-Touch LSIG electronic trip unit.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • S short-circuit performance level.
  • 50 kA Icu and Ics at 415 V AC.
  • Fixed mounting configuration with front terminals.
  • Stored-energy operating mechanism.

Advanced Circuit Protection for Power Distribution

Moulded-case circuit breakers such as the ABB Tmax XT7 protect electrical distribution systems by automatically interrupting current when overloads, short circuits or other abnormal conditions occur. Electronic trip technology provides precise and configurable protection characteristics, helping engineers coordinate protective devices and improve the reliability and selectivity of complex low-voltage networks.

The Ekip Hi-Touch LSIG trip unit combines overload, delayed short-circuit, instantaneous short-circuit and ground-fault protection in one advanced electronic protection system. Together with the XT7M stored-energy operating mechanism, high breaking capacity and robust fixed construction, the 1SDA101401R1 provides a capable protection solution for main distribution boards, industrial switchboards and high-current power distribution systems.

Typical Applications

  • Main and sub-main low-voltage distribution boards.
  • Industrial switchboards and power distribution assemblies.
  • Manufacturing and process plant electrical systems.
  • Commercial building power distribution.
  • Infrastructure and utility distribution installations.
  • Protection of high-current feeders and distribution circuits.
  • Three-phase industrial power networks.

Technical Specifications

Series SACE Tmax XT
Frame / sub-type XT7M
Order code / SKU 1SDA101401R1
ABB product group T-Max XT 250 Range
Product type Moulded-case circuit breaker (MCCB)
Rated current (In) 1600 A
Rated uninterrupted current (Iu) 1600 A
Rated operational voltage 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Number of poles 3
Trip unit Ekip Hi-Touch LSIG
Release type Electronic
Protection functions Long-time, short-time, instantaneous and ground fault (LSIG)
Short-circuit performance level S
Rated ultimate breaking capacity (Icu) at 415 V AC 50 kA
Rated service breaking capacity (Ics) at 415 V AC 50 kA
Rated ultimate breaking capacity (Icu) at 690 V AC 30 kA
Rated short-time withstand current (Icw) 20 kA
Overload release adjustment range 640–1600 A
Mounting configuration Fixed
Terminal type Front terminals
Operating mechanism Stored energy
Dimensions (W × D × H) 210 × 178 × 268 mm
Standard IEC 60947-2
Application Low-voltage power distribution protection

Frequently Asked Questions

What is the ABB 1SDA101401R1 used for?

The ABB 1SDA101401R1 is a 1600 A three-pole moulded-case circuit breaker designed to protect demanding low-voltage electrical distribution circuits against overloads, short circuits and ground faults.

What is the rated current of the XT7S M 1600?

The XT7S M 1600 has a rated current of 1600 A, making it suitable for high-current industrial, commercial and infrastructure power distribution applications.

What protection does the Ekip Hi-Touch LSIG trip unit provide?

The Ekip Hi-Touch LSIG electronic trip unit provides long-time, short-time, instantaneous and ground-fault protection, commonly abbreviated as LSIG.

What is the breaking capacity of the ABB 1SDA101401R1?

The XT7S M 1600 has a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC and 30 kA at 690 V AC.

How is the ABB XT7S M 1600 installed?

This version has a fixed three-pole configuration with front terminals and a stored-energy operating mechanism for integration into low-voltage switchboards, distribution panels and industrial power systems.