ABB 1SDA101264R1 XT7L 1250 is a fixed four-pole 1250 A moulded case circuit breaker with front terminals, 120 kA ultimate short-circuit breaking capacity at 400 V AC and an Ekip G Dip LS/I electronic trip unit designed for generator and low-voltage circuit protection.

SKU: 1SDA101264R1MPN: 1SDA101264R1
Price
List Price £7,328.65 ex VAT
Your Price (ex VAT) Save 25%
£5,496.49 25% OFF
You save £1,832.16 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,496.49
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,496.49

Why Choose the ABB 1SDA101264R1 XT7L 1250 Circuit Breaker?

The ABB 1SDA101264R1 is a high-performance SACE Tmax XT moulded case circuit breaker (MCCB) designed for generator, transformer and installation protection in demanding low-voltage electrical distribution systems. Identified as XT7L 1250 Ekip G Dip LS/I In=1250A 4p F F, this four-pole circuit breaker combines fixed construction, front terminals, lever operation and ABB's Ekip G Dip LS/I electronic trip unit.

As part of the ABB SACE Tmax XT7 range, the breaker is specifically configured with the Ekip G Dip LS/I release for generator protection applications. Its electronic protection functions provide long-time overload and instantaneous short-circuit protection, helping safeguard generators and associated distribution circuits against damaging overcurrent conditions.

With a rated uninterrupted current of 1250 A, rated voltage of 690 V and an ultimate short-circuit breaking capacity of 120 kA at 400 V AC, 50 Hz, the 1SDA101264R1 is suited to high-capacity generator systems, industrial switchboards and critical power distribution installations. Its fixed four-pole construction with front terminals provides practical integration into low-voltage switchgear assemblies.

Key Advantages

  • High-performance ABB SACE Tmax XT7L moulded case circuit breaker for generator and power distribution protection.
  • 1250 A rated uninterrupted current for high-current electrical installations.
  • Four-pole configuration for three-phase systems requiring four-pole switching and protection.
  • Ekip G Dip LS/I electronic trip unit designed for generator protection applications.
  • Electronic long-time overload and instantaneous short-circuit protection.
  • 120 kA ultimate short-circuit breaking capacity at 400 V AC, 50 Hz for installations with high prospective fault currents.
  • Fixed construction with front terminals simplifies integration into switchboards and distribution panels.

Key Features

  • ABB SACE Tmax XT7L series.
  • 1250 A rated uninterrupted current.
  • Four-pole circuit breaker.
  • Ekip G Dip LS/I electronic trip unit.
  • Designed for generator protection applications.
  • Long-time overload protection.
  • Instantaneous short-circuit protection.
  • 690 V rated voltage.
  • 120 kA ultimate short-circuit breaking capacity at 400 V AC, 50 Hz.
  • Adjustable overload protection from 500–1250 A.
  • Fixed circuit-breaker construction.
  • Front terminal connection.
  • Lever / toggle operating mechanism for manual switching.
  • Optional motor operating mechanism for automated applications.
  • IP20 protection rating.

Generator Circuit Protection with Ekip G Dip

Generator circuit breakers protect generating equipment and associated distribution networks against abnormal current conditions while providing reliable switching and isolation. Generator applications can have different fault-current characteristics from utility-fed distribution systems, making appropriately configured electronic protection important for dependable operation and equipment protection.

ABB's Ekip G Dip LS/I trip unit is designed for generator protection applications and combines adjustable long-time overload protection with short-circuit protection functions. When integrated with the high-breaking-capacity XT7L platform, it provides a robust solution for generator feeders, standby power systems and industrial installations where dependable circuit protection is essential.

Typical Applications

  • Generator protection and generator outgoing circuits.
  • Standby and emergency power generation systems.
  • Industrial low-voltage switchboards and distribution panels.
  • Transformer and installation protection.
  • Main and sub-main electrical distribution circuits.
  • High-current incoming and distribution feeders.
  • Manufacturing plants and critical infrastructure.
  • OEM switchgear and generator control panel building.

Technical Specifications

Series SACE Tmax XT
Frame size XT7
Order code / MPN 1SDA101264R1
Product group T-Max XT 250 Range
Product type Moulded case circuit breaker (MCCB)
Primary application Generator, transformer and installation protection
Rated uninterrupted current (Iu) 1250 A
Rated current (In) 1250 A
Rated voltage 690 V
Number of poles 4
Trip unit Ekip G Dip LS/I
Trip unit technology Electronic / solid-state
Protection functions Long-time overload and instantaneous short-circuit protection (LS/I)
Overload release current setting 500–1250 A
Short-time delayed short-circuit setting 750–12500 A
Instantaneous short-circuit setting 1250–12500 A
Integrated earth-fault protection No
Interruption rating L
Ultimate short-circuit breaking capacity (Icu) 120 kA at 400 V AC, 50 Hz
Power loss 57 W
Mounting type Fixed
Terminal position Front
Main circuit connection Bolted connection
Operating mechanism Lever / toggle
Motor drive Optional
Protection rating IP20
EAN 8056221010825

Frequently Asked Questions

What is the ABB 1SDA101264R1 used for?

The ABB 1SDA101264R1 is a four-pole moulded case circuit breaker equipped with an Ekip G Dip LS/I electronic trip unit and is particularly suited to generator protection as well as transformer and installation protection applications.

What is the rated current of the ABB 1SDA101264R1?

The XT7L 1250 has a rated uninterrupted current of 1250 A, making it suitable for high-current generator and low-voltage power distribution applications.

What protection does the Ekip G Dip LS/I trip unit provide?

The Ekip G Dip LS/I electronic trip unit provides configurable long-time overload and short-circuit protection functions designed to protect generators and associated electrical distribution circuits.

What is the breaking capacity of the ABB XT7L 1250?

The ABB XT7L version has an ultimate short-circuit breaking capacity of 120 kA at 400 V AC, 50 Hz, providing high fault-interruption capability for demanding electrical installations.

How is the ABB 1SDA101264R1 installed?

The 1SDA101264R1 is a fixed four-pole circuit breaker with front terminals and a lever / toggle operating mechanism, designed for installation within low-voltage switchboards, generator panels and industrial electrical assemblies.

Trusted Generator and Industrial Circuit Protection from ABB

ABB SACE Tmax XT circuit breakers provide dependable low-voltage circuit protection for generator, industrial and infrastructure applications, combining electronic trip technology, high breaking performance and flexible integration into modern electrical distribution systems.