Standard delivery
£8 ex VAT · free over £200UK parcel delivery is £8 ex VAT, or free on orders over £200 ex VAT.
Heavier items may be charged at a weight-based or pallet rate, shown at checkout.
ABB 1SDA101258R1 XT7L 800 is a fixed four-pole 800 A moulded case circuit breaker with front terminals, 120 kA ultimate short-circuit breaking capacity at 415 V AC and an Ekip Hi-Touch LSIG electronic trip unit for advanced overload, short-circuit and ground-fault protection.
£8,475.12
The ABB 1SDA101258R1 is a high-performance SACE Tmax XT moulded case circuit breaker (MCCB) designed for dependable protection and switching in demanding low-voltage electrical distribution systems. Identified as XT7L 800 Ekip Hi-Touch LSIG In=800A 4p F F, this four-pole circuit breaker combines fixed construction, front terminals, lever operation and ABB's advanced Ekip Hi-Touch LSIG electronic trip unit.
As part of the ABB SACE Tmax XT7 range, the breaker provides comprehensive configurable electronic protection against overload, short-circuit and earth-fault conditions. The Ekip Hi-Touch LSIG trip unit incorporates long-time, short-time, instantaneous and ground-fault protection functions, making the breaker suitable for sophisticated power distribution systems where advanced protection and effective coordination are required.
With a rated uninterrupted current of 800 A, rated operational voltage up to 690 V AC and an ultimate short-circuit breaking capacity of 120 kA at 415 V AC, the 1SDA101258R1 is well suited to industrial switchboards, high-current distribution feeders, infrastructure systems and other demanding electrical installations. Its fixed four-pole construction with front terminals supports practical integration into low-voltage switchboards and distribution assemblies.
Moulded case circuit breakers such as the ABB XT7L protect electrical circuits against damaging overload, short-circuit and earth-fault conditions while providing reliable switching and isolation. The XT7L's high interruption capability makes it particularly suitable for industrial installations and major distribution systems where prospective fault currents can be substantial.
The Ekip Hi-Touch LSIG electronic trip unit combines long-time, short-time, instantaneous and ground-fault protection functions within ABB's advanced electronic protection platform. Configurable protection characteristics support effective coordination while helping safeguard conductors, equipment and critical low-voltage distribution networks.
| Series | SACE Tmax XT |
|---|---|
| Frame size | XT7 |
| Order code / MPN | 1SDA101258R1 |
| Product group | T-Max XT 250 Range |
| Product type | Moulded case circuit breaker (MCCB) |
| Rated uninterrupted current (Iu) | 800 A |
| Rated operational voltage (Ue) | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Number of poles | 4 |
| Trip unit | Ekip Hi-Touch LSIG |
| Trip unit technology | Electronic / solid-state |
| Protection functions | Long-time, short-time, instantaneous and ground-fault protection (LSIG) |
| Interruption rating | L |
| Ultimate short-circuit breaking capacity (Icu) | 120 kA at 415 V AC |
| Service short-circuit breaking capacity (Ics) | 120 kA at 415 V AC |
| Rated short-time withstand current (Icw) | 20 kA |
| Power loss | 24 W per pole at rated operating conditions |
| Mounting type | Fixed |
| Terminal type | Front terminals |
| Main circuit connection | Bolted connection |
| Operating mechanism | Lever / toggle |
| Motor drive | Optional |
| Protection rating | IP20 |
| EAN | 8056221010764 |
| Dimensions (W × H × D) | 280 × 268 × 166 mm |
| Net weight | 12.5 kg |
The ABB 1SDA101258R1 is a four-pole moulded case circuit breaker used to protect and switch high-current low-voltage electrical distribution circuits in industrial, commercial and infrastructure applications.
The XT7L 800 has a rated uninterrupted current of 800 A, making it suitable for demanding high-current power distribution applications.
The Ekip Hi-Touch LSIG electronic trip unit provides long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault protection for connected circuits and electrical equipment.
The XT7L 800 provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC, with a service short-circuit breaking capacity of 120 kA at the same voltage.
The 1SDA101258R1 is a fixed four-pole circuit breaker with front terminals and a lever operating mechanism, designed for installation within low-voltage switchboards, distribution panels and industrial electrical assemblies.
ABB SACE Tmax XT circuit breakers are widely used by panel builders, electrical engineers and industrial operators for reliable low-voltage circuit protection, high breaking performance and flexible integration into modern power distribution systems.
We use cookies