1SDA101250R1 ABB XT7L 800 Ekip Touch Measuring LSIG 800A 4-Pole Circuit Breaker

1SDA101250R1 ABB XT7L 800 Ekip Touch Measuring LSIG 800A 4-Pole Circuit Breaker

ABB 1SDA101250R1 is an XT7L 800 four-pole fixed moulded case circuit breaker with an 800 A rated current, 120 kA breaking-capacity class and Ekip Touch Measuring LSIG electronic protection and measurement functionality.

SKU: 1SDA101250R1MPN: 1SDA101250R1
Price
List Price £8,468.88 ex VAT
Your Price (ex VAT) Save 25%
£6,351.66 25% OFF
You save £2,117.22 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £6,351.66
Trade pricing is personalised to your account

Manufacturer Lead Time

£6,351.66

Why Choose the ABB 1SDA101250R1 Tmax XT7L Circuit Breaker?

The ABB 1SDA101250R1 is a high-performance SACE Tmax XT7L moulded case circuit breaker designed for advanced protection and measurement in demanding low-voltage electrical distribution systems. As part of the ABB SACE Tmax XT series, this four-pole fixed circuit breaker combines an 800 A rated current with the sophisticated Ekip Touch Measuring LSIG electronic trip unit.

The Ekip Touch Measuring LSIG release combines electronic circuit protection with advanced measurement functionality. Its LSIG protection provides long-time, short-time, instantaneous and earth-fault protection functions, helping protect electrical installations against overload, short-circuit and earth-fault conditions while supporting detailed monitoring of the electrical system.

The 1SDA101250R1 is supplied as a four-pole fixed circuit breaker with front terminals and a lever operating mechanism. The XT7L configuration provides a 120 kA breaking-capacity class, making this breaker particularly suitable for high-current switchboards and industrial distribution systems where substantial fault interruption capability, electronic protection and electrical measurement are required.

Key Advantages

  • High-performance ABB SACE Tmax XT7L moulded case circuit breaker.
  • 800 A rated current for high-current low-voltage distribution systems.
  • Four-pole configuration for comprehensive circuit switching and protection.
  • Advanced Ekip Touch Measuring LSIG electronic trip unit.
  • Long-time, short-time, instantaneous and earth-fault protection functions.
  • Integrated measuring functionality for enhanced electrical-system monitoring.
  • 120 kA XT7L breaking-capacity class for demanding fault-current conditions.
  • Fixed execution with front terminals for switchboard integration.

Key Features

  • ABB SACE Tmax XT series.
  • XT7 frame size.
  • XT7L 800 circuit-breaker configuration.
  • 800 A rated current.
  • 4-pole construction.
  • Ekip Touch Measuring LSIG solid-state electronic release.
  • LSIG overload, short-time, instantaneous and earth-fault protection.
  • Integrated electrical measurement functionality.
  • Fixed circuit-breaker execution.
  • Front terminal connection arrangement.
  • Lever operating mechanism.
  • IEC-compliant configuration for AC applications.

Advanced Protection and Measurement for Power Distribution

Moulded case circuit breakers such as the ABB Tmax XT7L protect electrical systems by interrupting current when abnormal overload, short-circuit or earth-fault conditions are detected. Electronic trip technology enables precise and repeatable protection characteristics for demanding industrial and commercial distribution networks.

The Ekip Touch Measuring LSIG trip unit extends this capability with integrated measurement functions for enhanced visibility of electrical operating conditions. Combined with the XT7L frame, four-pole construction and fixed front-terminal arrangement, the 1SDA101250R1 provides a comprehensive solution for protecting and monitoring high-current low-voltage distribution systems.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Main and sub-main electrical distribution circuits.
  • Manufacturing and process-industry electrical systems.
  • Commercial and industrial power infrastructure.
  • High-current distribution panels requiring electrical measurement.
  • Electrical switchgear and panel-building applications.

Technical Specifications

Series SACE Tmax XT
Order code 1SDA101250R1
Product type Moulded case circuit breaker
Frame size XT7
Breaking-capacity class L
Breaking capacity 120 kA
Rated current 800 A
Number of poles 4
Trip unit Ekip Touch Measuring LSIG
Trip-unit technology Electronic / solid-state
Protection functions Long-time, short-time, instantaneous and earth-fault
Installation Fixed
Terminal arrangement Front terminals
Operating mechanism Lever
Application AC low-voltage circuit protection
Standard IEC
Dimensions (H × W × D) 268 × 280 × 166 mm
Weight 12.5 kg
EAN / UPC 8056221010689

Frequently Asked Questions

What is the ABB 1SDA101250R1 used for?

The ABB 1SDA101250R1 is an 800 A four-pole Tmax XT7L moulded case circuit breaker designed for advanced protection and measurement in demanding low-voltage electrical distribution systems.

What trip unit is fitted to the ABB 1SDA101250R1?

It is fitted with an Ekip Touch Measuring LSIG electronic trip unit combining advanced circuit protection with electrical measurement functionality.

What protection functions does the Ekip Touch Measuring LSIG provide?

The trip unit provides long-time, short-time, instantaneous and earth-fault protection functions for comprehensive electrical circuit protection.

What is the rated current of the ABB 1SDA101250R1?

The circuit breaker has a rated current of 800 A and uses a four-pole configuration.

How is the ABB XT7L 1SDA101250R1 installed?

This model is supplied as a fixed four-pole circuit breaker with front terminals and a lever operating mechanism for integration into low-voltage switchboards and distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers are widely used by electrical engineers, panel builders and industrial operators for reliable low-voltage circuit protection, advanced electrical monitoring and integration into modern power-distribution systems.