1SDA101232R1 ABB XT7L 1250 Ekip Dip LSI 1250A 4-Pole Circuit Breaker

1SDA101232R1 ABB XT7L 1250 Ekip Dip LSI 1250A 4-Pole Circuit Breaker

ABB 1SDA101232R1 XT7L 1250 is a fixed four-pole 1250 A moulded case circuit breaker with an Ekip Dip LSI electronic trip unit and 120 kA breaking capacity at 415 V AC for demanding low-voltage power distribution applications.

SKU: 1SDA101232R1MPN: 1SDA101232R1
Price
List Price £7,254.56 ex VAT
Your Price (ex VAT) Save 25%
£5,440.92 25% OFF
You save £1,813.64 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £5,440.92
Trade pricing is personalised to your account

Manufacturer Lead Time

£5,440.92

Why Choose the ABB XT7L 1250 Ekip Dip LSI 1SDA101232R1 Circuit Breaker?

The ABB 1SDA101232R1 is a high-performance four-pole moulded case circuit breaker (MCCB) designed for reliable protection, switching and isolation in demanding low-voltage power distribution systems. Part of the ABB SACE Tmax XT7 range, this XT7L breaker combines a 1250 A rated current with an Ekip Dip LSI electronic trip unit for adjustable overload and short-circuit protection.

The Ekip Dip LSI solid-state release provides long-time, short-time and instantaneous protection, allowing the breaker to respond effectively to overload and short-circuit conditions. Adjustable protection settings enable improved coordination with other protective devices, making the XT7L suitable for sophisticated industrial and commercial electrical distribution networks.

With a rated uninterrupted current of 1250 A, a four-pole configuration and an ultimate short-circuit breaking capacity of 120 kA at 415 V AC, the 1SDA101232R1 provides substantial fault-clearing capability for high-current distribution circuits. Its fixed construction, front terminals and lever operating mechanism make it suitable for integration into low-voltage switchboards and power distribution assemblies.

Key Advantages

  • High-performance ABB SACE Tmax XT7L moulded case circuit breaker.
  • 1250 A rated current for demanding power distribution applications.
  • Four-pole configuration for three-phase systems with neutral.
  • Ekip Dip LSI electronic trip unit for comprehensive circuit protection.
  • Long-time, short-time and instantaneous protection functions.
  • High 120 kA ultimate breaking capacity at 415 V AC.
  • Adjustable protection settings support selective circuit coordination.
  • Fixed construction with front terminals for switchboard integration.

Key Features

  • ABB SACE Tmax XT7L series.
  • 1250 A rated current.
  • 4-pole configuration.
  • Ekip Dip LSI solid-state electronic release.
  • Long-time overload protection.
  • Short-time delayed short-circuit protection.
  • Instantaneous short-circuit protection.
  • Long-time setting range: 0.4–1 × In.
  • Short-time setting range: 1–10 × In.
  • Instantaneous setting range: 1–15 × In.
  • L short-circuit performance level.
  • Fixed mounting configuration.
  • Front terminal connections.
  • Lever operating mechanism.

High-Performance Protection for Power Distribution

Moulded case circuit breakers such as the ABB XT7L protect low-voltage electrical distribution systems against overloads and short circuits while also providing dependable switching and isolation. The XT7L combines a high current rating with substantial short-circuit breaking capability, making it particularly suitable for installations where high prospective fault currents require robust protection.

The Ekip Dip LSI electronic trip unit provides long-time, short-time and instantaneous protection with adjustable thresholds. This allows protection characteristics to be matched to the electrical installation and coordinated with upstream and downstream protective devices, helping improve selectivity, equipment protection and continuity of supply.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main and sub-main power distribution circuits.
  • High-current feeder protection.
  • Manufacturing and process plants.
  • Commercial building electrical distribution.
  • Infrastructure and utility installations.
  • Transformer and generator distribution systems.
  • Low-voltage switchgear and distribution assemblies.

Technical Specifications

Series SACE Tmax XT
Frame XT7
Order code / MPN 1SDA101232R1
Product type Moulded case circuit breaker
Application Power distribution protection
Rated current (In) 1250 A
Rated uninterrupted current (Iu) 1250 A
Number of poles 4
Trip unit Ekip Dip LSI
Release type Electronic / solid-state
Protection functions Long-time, short-time and instantaneous (LSI)
Long-time protection setting (I1) 0.4–1 × In
Short-time protection setting (I2) 1–10 × In
Instantaneous protection setting (I3) 1–15 × In
Rated operational voltage 690 V AC
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 120 kA
Short-circuit performance level L
Mounting version Fixed
Terminal connection Front
Main circuit connection Bolt connection
Operating mechanism Lever
Protection rating IP20
Motor operator Optional
Standard IEC 60947-2
Dimensions (H × W × D) 268 × 280 × 166 mm
Net weight 12.5 kg
Power loss 57 W
EAN 8056221015356

Frequently Asked Questions

What is the ABB 1SDA101232R1 used for?

The ABB 1SDA101232R1 is a 1250 A four-pole moulded case circuit breaker designed to protect, switch and isolate demanding low-voltage power distribution circuits.

What trip unit is fitted to the ABB XT7L 1250 1SDA101232R1?

The breaker is fitted with an Ekip Dip LSI electronic trip unit, providing adjustable long-time, short-time and instantaneous protection functions.

What is the rated current of this circuit breaker?

The ABB 1SDA101232R1 has a rated current of 1250 A.

What is the breaking capacity of the ABB XT7L 1250?

The XT7L version provides an ultimate short-circuit breaking capacity of 120 kA at 415 V AC, making it suitable for demanding electrical installations with high prospective fault currents.