ABB 1SDA101208R1 XT7H 1250 is a 1250 A four-pole fixed generator-protection moulded case circuit breaker with an Ekip G Dip LS/I electronic trip unit and a 70 kA ultimate short-circuit breaking capacity at 415 V AC.
£4,588.61
The ABB 1SDA101208R1 is a high-performance four-pole moulded case circuit breaker (MCCB) specifically configured for generator protection in demanding low-voltage AC electrical systems. Identified by ABB as the XT7H 1250 Ekip G Dip LS/I In1250A 4p F F, it combines the robust SACE Tmax XT7 platform with ABB’s Ekip G Dip LS/I electronic trip unit for industrial, commercial and infrastructure power installations.
This fixed circuit breaker features the Ekip G Dip LS/I electronic trip unit, designed for generator applications and providing long-time, short-time and instantaneous protection functions. The generator-specific electronic release allows appropriate protection of generating equipment and associated distribution circuits while the XT7H platform provides high short-circuit interruption performance.
With a rated uninterrupted current of 1250 A, a rated operational voltage of 690 V AC and an ultimate short-circuit breaking capacity of 70 kA at 415 V AC, the XT7H 1250 is engineered for high-current generator and distribution applications. Its fixed four-pole construction, front connections and toggle operating mechanism support straightforward integration into generator switchboards and low-voltage distribution assemblies.
Generator circuits require protection characteristics suited to the operating behaviour and fault-current capability of generating equipment. The ABB XT7H 1250 with Ekip G Dip LS/I combines generator-oriented electronic protection with the high interruption performance of the SACE Tmax XT7H platform, helping protect generators and their associated low-voltage distribution circuits against overload and short-circuit conditions.
The Ekip G Dip LS/I release provides long-time, short-time and instantaneous protection while the breaker’s 70 kA Icu at 415 V AC and 20 kA short-time withstand capability support demanding generator switchboard applications. Its four-pole fixed configuration is particularly suitable for three-phase generator systems where switching and protection of the neutral conductor are required.
| Product group | T-Max XT 250 Range |
|---|---|
| Series | SACE Tmax XT |
| Order code | 1SDA101208R1 |
| Product type | Moulded case circuit breaker (MCCB) |
| Application | Generator protection |
| Frame size | XT7 |
| Performance level | H |
| Rated current (In) | 1250 A |
| Rated uninterrupted current (Iu) | 1250 A |
| Trip unit | Ekip G Dip LS/I |
| Release type | Electronic |
| Protection functions | Long-time, short-time and instantaneous (LS/I) |
| Integrated earth-fault protection | No |
| Number of poles | 4 |
| Rated operational voltage | 690 V AC |
| Rated insulation voltage (Ui) | 1000 V |
| Rated impulse withstand voltage (Uimp) | 8 kV |
| Ultimate short-circuit breaking capacity (Icu) at 220–240 V AC | 100 kA |
| Ultimate short-circuit breaking capacity (Icu) at 380 V AC | 70 kA |
| Ultimate short-circuit breaking capacity (Icu) at 415 V AC | 70 kA |
| Ultimate short-circuit breaking capacity (Icu) at 440 V AC | 65 kA |
| Ultimate short-circuit breaking capacity (Icu) at 500–525 V AC | 50 kA |
| Ultimate short-circuit breaking capacity (Icu) at 690 V AC | 42 kA |
| Service short-circuit breaking capacity (Ics) at 415 V AC | 70 kA |
| Rated short-time withstand current (Icw) | 20 kA |
| Overload release current setting | 1250 A |
| Short-time delayed short-circuit release setting | 12500 A |
| Installation | Fixed |
| Main circuit connection | Bolt connection |
| Connection position | Front |
| Operating element | Toggle |
| Motor drive | Optional |
| Degree of protection | IP20 |
The ABB 1SDA101208R1 is a four-pole moulded case circuit breaker configured for generator protection, providing electronic overload and short-circuit protection for low-voltage generating systems and associated distribution circuits.
The circuit breaker has a rated uninterrupted current of 1250 A, making it suitable for high-current generator and distribution applications.
The breaker is fitted with an Ekip G Dip LS/I electronic trip unit, a generator-oriented release providing long-time, short-time and instantaneous protection functions.
The XT7H has an ultimate short-circuit breaking capacity of 70 kA at 415 V AC. Its Icu ratings also include 100 kA at 220–240 V AC, 65 kA at 440 V AC, 50 kA at 500–525 V AC and 42 kA at 690 V AC.
The 1SDA101208R1 is a fixed four-pole circuit breaker with front main-circuit connections, designed for integration into generator switchboards and low-voltage power distribution assemblies.
ABB SACE Tmax XT circuit breakers are widely used in generator, industrial and commercial power systems to provide dependable circuit protection, electronic trip functionality and high short-circuit performance for modern low-voltage installations.