1SDA101172R1 ABB XT7H 1250 Ekip Dip LS/I In=1250A 4p F F Circuit Breaker

1SDA101172R1 ABB XT7H 1250 Ekip Dip LS/I In=1250A 4p F F Circuit Breaker

ABB 1SDA101172R1 XT7H 1250 Ekip Dip LS/I four-pole fixed moulded case circuit breaker with a 1250 A rated current, 70 kA breaking capacity at 415 V AC, front terminals and adjustable electronic overload and instantaneous short-circuit protection.

SKU: 1SDA101172R1MPN: 1SDA101172R1
Price
List Price £5,503.58 ex VAT
Your Price (ex VAT) Save 25%
£4,127.69 25% OFF
You save £1,375.90 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £4,127.69
Trade pricing is personalised to your account

Manufacturer Lead Time

£4,127.69

Why Choose the ABB XT7H 1250 Ekip Dip LS/I In=1250A 4p F F Circuit Breaker?

The ABB XT7H 1250 Ekip Dip LS/I In=1250A 4p F F, order code 1SDA101172R1, is a high-performance four-pole moulded case circuit breaker (MCCB) from the ABB SACE Tmax XT range. Designed for demanding low-voltage power distribution applications, it combines a 1250 A rated current with an Ekip Dip LS/I solid-state electronic trip unit and the higher-breaking-capacity XT7H performance level.

The Ekip Dip LS/I electronic release provides adjustable long-time overload and instantaneous short-circuit protection. With an overload setting range of 0.4–1 × In and instantaneous protection adjustable from 1–10 × In, the breaker can be coordinated with the characteristics of the protected installation while providing reliable protection against overloads and severe short-circuit faults.

As an XT7H version, the 1SDA101172R1 provides a rated ultimate short-circuit breaking capacity of 70 kA at 415 V AC. Its four-pole fixed construction, front terminals and lever operating mechanism make it well suited to high-current industrial and commercial switchboards where increased fault-interruption performance is required.

Key Advantages

  • High-performance 1250 A moulded case circuit breaker for demanding low-voltage distribution.
  • XT7H high-breaking-capacity version for installations with elevated prospective fault currents.
  • 70 kA Icu at 415 V AC.
  • Four-pole configuration suitable for three-phase systems with neutral.
  • Ekip Dip LS/I electronic trip unit for adjustable overload and instantaneous short-circuit protection.
  • Overload protection adjustable from 500–1250 A.
  • Instantaneous short-circuit protection adjustable from 1250–12500 A.
  • Fixed installation with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT7H moulded case circuit breaker.
  • 1250 A rated current.
  • Four-pole construction.
  • Ekip Dip LS/I solid-state electronic release.
  • Long-time overload and instantaneous short-circuit protection.
  • Overload setting range of 0.4–1 × In.
  • Instantaneous short-circuit setting range of 1–10 × In.
  • 70 kA rated ultimate short-circuit breaking capacity at 415 V AC.
  • H interruption rating.
  • Fixed circuit breaker construction.
  • Front terminals for main circuit connections.
  • Lever operating mechanism.

High-Capacity Electronic Protection for Power Distribution

The ABB Ekip Dip LS/I trip unit combines adjustable long-time overload protection with instantaneous short-circuit protection. For the 1250 A version, the overload threshold can be adjusted across 500–1250 A, while instantaneous protection spans 1250–12500 A, allowing the breaker response to be matched to the electrical installation and its protection requirements.

The XT7H platform is particularly suited to installations where higher fault-current interruption is required. Its 70 kA Icu at 415 V AC, four-pole construction and fixed front-terminal arrangement make the 1SDA101172R1 a strong choice for main distribution boards, industrial switchgear and high-current feeders in demanding low-voltage systems.

Typical Applications

  • Industrial low-voltage switchboards.
  • Main distribution boards.
  • Transformer-fed electrical distribution systems.
  • High-current main and sub-main feeders.
  • Manufacturing and process plants.
  • Commercial and infrastructure electrical systems.
  • Power distribution systems with elevated prospective fault currents.
  • Circuits requiring adjustable electronic overload and short-circuit protection.

Technical Specifications

Series SACE Tmax XT
Order code / Product ID 1SDA101172R1
Alternate catalogue number XT7HE412EEFF000XXX
Product type Moulded case circuit breaker (MCCB)
Frame size XT7
Breaking-performance version XT7H
Rated current 1250 A
Number of poles 4
Trip unit Ekip Dip LS/I
Release type Solid-state electronic release
Protection functions Long-time overload and instantaneous short circuit (LS/I)
Overload release setting 0.4–1 × In
Overload release adjustment range 500–1250 A
Instantaneous short-circuit setting 1–10 × In
Instantaneous short-circuit adjustment range 1250–12500 A
Interruption rating H
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 70 kA
Installation Fixed
Terminal position Front
Operating mechanism Lever
Current type AC
Standard IEC 60947-2
Approximate weight 12.5 kg
EAN / UPC 8056221014755

Frequently Asked Questions

What is the ABB 1SDA101172R1 used for?

The ABB 1SDA101172R1 is a 1250 A four-pole moulded case circuit breaker designed for demanding low-voltage power distribution systems requiring electronic overload and short-circuit protection with high fault-breaking performance.

What is the rated current of the ABB XT7H 1SDA101172R1?

The circuit breaker has a rated current of 1250 A. Its long-time overload setting is adjustable from 0.4–1 × In, corresponding to 500–1250 A.

Which trip unit is fitted to the ABB 1SDA101172R1?

The 1SDA101172R1 is fitted with an Ekip Dip LS/I solid-state electronic trip unit providing adjustable long-time overload and instantaneous short-circuit protection.

What is the breaking capacity of the ABB XT7H 1250 1SDA101172R1?

The XT7H version has a rated ultimate short-circuit breaking capacity of 70 kA at 415 V AC, providing increased fault-interruption performance compared with the XT7S version.

How is the ABB XT7H 1SDA101172R1 installed?

The 1SDA101172R1 is a fixed four-pole circuit breaker with front terminals and a lever operating mechanism, designed for integration into low-voltage switchboards and power distribution assemblies.

Trusted High-Performance Protection from ABB

ABB SACE Tmax XT moulded case circuit breakers combine configurable electronic protection, high short-circuit breaking performance and robust construction for demanding industrial, commercial and infrastructure low-voltage power distribution systems.