1SDA101150R1 ABB XT7S 800 Ekip G Dip LS/I In=800A 4p F F Circuit Breaker

1SDA101150R1 ABB XT7S 800 Ekip G Dip LS/I In=800A 4p F F Circuit Breaker

ABB 1SDA101150R1 XT7S 800 Ekip G Dip LS/I four-pole fixed moulded case circuit breaker with an 800 A rated current, front terminals and electronic protection designed for generator applications.

SKU: 1SDA101150R1MPN: 1SDA101150R1
Price
List Price £3,268.38 ex VAT
Your Price (ex VAT) Save 25%
£2,451.29 25% OFF
You save £817.10 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,451.29
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,451.29

Why Choose the ABB XT7S 800 Ekip G Dip LS/I In=800A 4p F F Circuit Breaker?

The ABB XT7S 800 Ekip G Dip LS/I In=800A 4p F F, order code 1SDA101150R1, is a high-performance four-pole moulded case circuit breaker (MCCB) designed specifically for generator protection and demanding low-voltage electrical distribution applications. As part of the ABB SACE Tmax XT series, it combines an 800 A rated current with the Ekip G Dip LS/I electronic trip unit.

The Ekip G Dip LS/I solid-state release is designed to provide reliable overload and short-circuit protection while addressing the particular protection requirements associated with generator-fed electrical systems. Its electronic protection functions and adjustable settings allow the breaker to be coordinated with the characteristics of the installation, helping protect generators, conductors and connected electrical equipment.

With a rated uninterrupted current of 800 A, a four-pole configuration and a rated operational voltage of 690 V AC, the XT7S is suitable for substantial generator and power distribution systems. The S breaking-capacity version provides an ultimate short-circuit breaking capacity of 50 kA at 415 V AC, while its fixed construction and front terminals enable straightforward integration into low-voltage switchboards.

Key Advantages

  • High-performance 800 A moulded case circuit breaker for generator protection.
  • Four-pole configuration suitable for three-phase systems with neutral.
  • Purpose-designed Ekip G Dip LS/I electronic trip unit.
  • Electronic overload and short-circuit protection with adjustable settings.
  • 320–800 A overload release adjustment range.
  • 50 kA ultimate short-circuit breaking capacity at 415 V AC.
  • Fixed installation with front terminals for switchboard integration.
  • Part of the advanced ABB SACE Tmax XT circuit breaker platform.

Key Features

  • ABB SACE Tmax XT7S moulded case circuit breaker.
  • 800 A rated uninterrupted current.
  • Four-pole construction.
  • Ekip G Dip LS/I solid-state electronic release.
  • Designed for generator protection applications.
  • 690 V AC rated operational voltage.
  • 50 kA Icu at 415 V AC for the XT7S breaking-capacity class.
  • Adjustable overload protection from 320–800 A.
  • Adjustable delayed short-circuit protection from 480–8000 A.
  • Adjustable instantaneous short-circuit protection from 800–8000 A.
  • Fixed installation with front terminals.
  • Lever operating mechanism.

Reliable Protection for Generator Applications

Generator-fed electrical systems can require different protection characteristics from conventional utility-fed distribution networks because available short-circuit currents and operating conditions can vary significantly. The ABB Ekip G protection platform is designed for generator applications, combining electronic overload and short-circuit protection with adjustable settings that allow the protective response to be matched to the installation.

The XT7S platform combines this generator-focused protection with a robust high-current moulded case circuit breaker. With its 800 A current rating, four-pole construction and fixed front-terminal configuration, the 1SDA101150R1 is well suited to generator switchboards, standby power installations and industrial electrical distribution systems.

Typical Applications

  • Generator protection systems.
  • Generator control and distribution switchboards.
  • Standby and emergency power systems.
  • Industrial low-voltage switchboards.
  • Manufacturing and process plants.
  • Commercial and infrastructure power distribution.
  • High-current generator feeders.
  • Electrical systems requiring adjustable electronic protection.

Technical Specifications

Series SACE Tmax XT
Order code / Product ID 1SDA101150R1
Product type Moulded case circuit breaker (MCCB)
Frame XT7S
Application Generator protection
Rated uninterrupted current (Iu) 800 A
Rated current (In) 800 A
Number of poles 4
Trip unit Ekip G Dip LS/I
Release type Solid-state electronic release
Rated operational voltage 690 V AC
Rated ultimate short-circuit breaking capacity (Icu) at 415 V AC 50 kA
Overload release adjustment range 320–800 A
Delayed short-circuit release adjustment range 480–8000 A
Instantaneous short-circuit release adjustment range 800–8000 A
Breaking-capacity class S
Installation Fixed
Terminal type Front terminals
Operating mechanism Lever operating mechanism
Current type AC
Dimensions (W × H × D) 280 × 268 × 166 mm
Weight 12.5 kg
EAN 8056221014533

Frequently Asked Questions

What is the ABB 1SDA101150R1 used for?

The ABB 1SDA101150R1 is an 800 A four-pole moulded case circuit breaker equipped with an Ekip G Dip LS/I electronic trip unit for generator protection and low-voltage electrical distribution applications.

What is the rated current of the ABB XT7S 1SDA101150R1?

The circuit breaker has a rated uninterrupted current of 800 A.

Which trip unit is fitted to the ABB 1SDA101150R1?

The 1SDA101150R1 is fitted with an Ekip G Dip LS/I solid-state electronic trip unit designed for generator protection applications.

What is the breaking capacity of the ABB XT7S 800?

The XT7S S-version has a rated ultimate short-circuit breaking capacity of 50 kA at 415 V AC.

How is the ABB XT7S 1SDA101150R1 installed?

The 1SDA101150R1 is a fixed four-pole circuit breaker with front terminals and a lever operating mechanism, designed for installation within low-voltage switchboards and generator distribution assemblies.

Trusted Generator Protection from ABB