1SDA100895R1 ABB XT7H 1000 Ekip Dip LSI 1000A 3-Pole Circuit Breaker

1SDA100895R1 ABB XT7H 1000 Ekip Dip LSI 1000A 3-Pole Circuit Breaker

ABB 1SDA100895R1 XT7H 1000 is a 1000 A three-pole fixed moulded case circuit breaker with an Ekip Dip LSI electronic trip unit and 70 kA breaking capacity at 415 V AC for demanding transformer, generator and low-voltage electrical installation protection.

SKU: 1SDA100895R1MPN: 1SDA100895R1
Price
List Price £4,442.45 ex VAT
Your Price (ex VAT) Save 25%
£3,331.84 25% OFF
You save £1,110.61 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £3,331.84
Trade pricing is personalised to your account

Manufacturer Lead Time

£3,331.84

Why Choose the ABB 1SDA100895R1 XT7H 1000 Circuit Breaker?

The ABB 1SDA100895R1, type XT7H 1000 Ekip Dip LSI In=1000A 3p F F, is a high-performance moulded case circuit breaker (MCCB) for transformer, generator and electrical installation protection. Part of the ABB SACE Tmax XT range, this XT7H breaker combines a 1000 A rated uninterrupted current with an Ekip Dip LSI solid-state electronic trip unit for dependable protection of demanding low-voltage power distribution systems.

The Ekip Dip LSI electronic release provides long-time, short-time and instantaneous protection functions. This combination provides overload protection together with delayed and instantaneous short-circuit protection, supporting selective coordination between upstream and downstream protective devices while protecting cables, busbars, transformers and other connected equipment.

The XT7H performance level delivers an ultimate short-circuit breaking capacity of 70 kA at 415 V AC, with additional breaking capability across operating voltages up to 690 V AC. Its fixed three-pole construction, front terminals, bolted main-circuit connections and lever operating mechanism provide a robust configuration for industrial switchboards, generator systems and high-current electrical distribution assemblies.

Key Advantages

  • High-performance ABB SACE Tmax XT moulded case circuit breaker for demanding low-voltage distribution systems.
  • 1000 A rated uninterrupted current for high-current industrial and commercial applications.
  • Ekip Dip LSI electronic trip unit for overload, short-time and instantaneous short-circuit protection.
  • Short-time protection supports improved selectivity and coordination between protective devices.
  • 70 kA ultimate short-circuit breaking capacity at 415 V AC with XT7H performance.
  • Breaking capability maintained up to 42 kA at 690 V AC.
  • Three-pole fixed configuration with front terminals for straightforward switchboard integration.

Key Features

  • ABB SACE Tmax XT7H series.
  • 1000 A rated uninterrupted current.
  • Ekip Dip LSI solid-state electronic release.
  • L, S and I protection functions for overload, short-time and instantaneous short-circuit protection.
  • H short-circuit performance level for systems with high prospective fault currents.
  • 70 kA breaking capacity at 415 V AC.
  • 690 V rated voltage.
  • No integrated earth-fault protection.
  • Three-pole fixed-mounted design with front main-circuit connections.
  • Lever operating mechanism with optional motor drive capability.

Selective Electronic Protection for Power Distribution Systems

The ABB Ekip Dip LSI electronic trip unit combines long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection in a solid-state release. The addition of short-time protection supports improved selectivity between protective devices, helping engineers coordinate fault-clearing characteristics throughout complex low-voltage distribution networks while maintaining rapid interruption of severe faults.

The XT7H version is designed for installations where substantial short-circuit performance is required. With its 1000 A rating, 70 kA breaking capability at 415 V AC and fixed front-terminal configuration, the 1SDA100895R1 is particularly suited to industrial switchboards, transformer and generator protection, main distribution panels and high-current feeder circuits.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Transformer and generator protection systems.
  • Main and sub-main electrical distribution.
  • High-fault-level power distribution systems.
  • Commercial and industrial electrical installations.
  • Manufacturing and process plant switchboards.
  • Infrastructure and utility electrical systems.
  • High-current feeders and distribution circuits.

Technical Specifications

Series SACE Tmax XT
Frame size XT7
Order code / MPN 1SDA100895R1
Product type Moulded case circuit breaker
Application Transformer, generator and electrical installation protection
Rated current (In) 1000 A
Rated uninterrupted current (Iu) 1000 A
Rated voltage 690 V
Number of poles 3
Current type AC
Trip unit Ekip Dip LSI
Release type Solid-state electronic
Protection functions L, S, I
Integrated earth-fault protection No
Short-circuit performance level H
Ultimate breaking capacity at 240 V AC 100 kA
Ultimate breaking capacity at 380 V AC 70 kA
Ultimate breaking capacity at 415 V AC 70 kA
Ultimate breaking capacity at 440 V AC 65 kA
Ultimate breaking capacity at 500 V AC 50 kA
Ultimate breaking capacity at 525 V AC 50 kA
Ultimate breaking capacity at 690 V AC 42 kA
Mounting type Fixed
Terminal position Front
Main circuit connection Bolted connection
Operating mechanism Lever
Complete device with protection unit Yes
Integrated motor operator No
Motor operator Optional
Degree of protection IP20
Power loss 37 W
Dimensions (W × H × D) 210 × 268 × 166 mm
Net weight 9.7 kg
Standard IEC 60947
EAN / GTIN 8056221009492

Frequently Asked Questions

What is the ABB 1SDA100895R1 used for?

The ABB 1SDA100895R1 is a 1000 A moulded case circuit breaker designed for transformer, generator and electrical installation protection in demanding low-voltage power distribution systems.

What trip unit is fitted to the ABB 1SDA100895R1?

The breaker is fitted with an Ekip Dip LSI solid-state electronic trip unit, providing long-time overload, short-time delayed short-circuit and instantaneous short-circuit protection.

What is the rated current of the ABB XT7H 1000?

The ABB 1SDA100895R1 has a rated uninterrupted current of 1000 A and is designed for high-current low-voltage distribution applications.

What breaking capacity does the XT7H 1000 provide?

The XT7H provides a short-circuit breaking capacity of 70 kA at 415 V AC. Its breaking capability is 100 kA at 240 V AC, 65 kA at 440 V AC, 50 kA at 500–525 V AC and 42 kA at 690 V AC.

How is the ABB 1SDA100895R1 installed?

This model is a fixed, three-pole circuit breaker with front terminals, bolted main-circuit connections and a lever operating mechanism for integration into low-voltage switchboards and power distribution assemblies.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breakers combine configurable electronic protection with high short-circuit performance, providing panel builders and electrical engineers with dependable protection for transformer, generator and demanding industrial low-voltage distribution applications.