1SDA100731R1 ABB XT6N 800 TMA 800-8000 4-Pole Fixed Circuit Breaker InN=100% In

1SDA100731R1 ABB XT6N 800 TMA 800-8000 4-Pole Fixed Circuit Breaker InN=100% In

ABB 1SDA100731R1 is an XT6N 800 A 4-pole fixed moulded-case circuit breaker with front terminals, a fully rated neutral and a TMA thermomagnetic release providing adjustable 560–800 A overload and 4000–8000 A instantaneous short-circuit protection.

SKU: 1SDA100731R1MPN: 1SDA100731R1
Price
List Price £3,003.77 ex VAT
Your Price (ex VAT) Save 25%
£2,252.83 25% OFF
You save £750.94 per unit
Manufacturer Lead Time Estimated Delivery 5 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £2,252.83
Trade pricing is personalised to your account

Manufacturer Lead Time

£2,252.83

Why Choose the ABB 1SDA100731R1 XT6N 800 TMA Circuit Breaker?

The ABB 1SDA100731R1 is a SACE Tmax XT6N moulded-case circuit breaker designed for dependable protection of demanding low-voltage power distribution systems. Rated at 800 A, this fixed 4-pole circuit breaker features front terminals and an ABB TMA thermomagnetic trip unit for overload and short-circuit protection.

The TMA release combines adjustable thermal overload protection with adjustable instantaneous magnetic short-circuit protection. The thermal setting covers 560–800 A, while the instantaneous magnetic protection can be set from 4000–8000 A, allowing the protection characteristics to be matched to the requirements of high-current feeders and distribution circuits.

The fourth pole features a fully rated neutral at 100% of the phase rated current (InN=100% In), making the breaker suitable for four-wire distribution systems where full neutral-current capacity is required. The XT6N version provides a rated ultimate short-circuit breaking capacity of 36 kA at 415 V AC and is suitable for operational voltages up to 690 V AC.

Key Advantages

  • 800 A rated current for high-current low-voltage distribution applications.
  • 4-pole construction with a fully rated neutral at 100% In.
  • Integrated TMA thermomagnetic release provides overload and short-circuit protection.
  • Adjustable thermal protection from 560–800 A.
  • Adjustable instantaneous magnetic protection from 4000–8000 A.
  • 36 kA ultimate breaking capacity at 415 V AC for robust fault interruption.
  • Fixed construction with front terminals for conventional switchboard installation.

Key Features

  • ABB SACE Tmax XT6N moulded-case circuit breaker.
  • 800 A rated uninterrupted current (Iu).
  • 4-pole configuration.
  • Fully rated neutral: InN=100% In.
  • TMA thermomagnetic trip unit.
  • Fixed circuit breaker execution.
  • Front terminals for power connections.
  • Adjustable thermal trip setting of 0.7–1 × In.
  • Adjustable instantaneous magnetic trip setting of 5–10 × In.
  • N breaking-capacity class.
  • Suitable for AC/DC applications in accordance with the product configuration.
  • Rated operational voltage up to 690 V AC.
  • Rated insulation voltage of 1000 V.
  • Rated impulse withstand voltage of 8 kV.

Thermomagnetic Protection with a Fully Rated Neutral

Thermomagnetic circuit breakers combine thermal overload protection with magnetic short-circuit protection. The thermal element responds to sustained overload currents, while the magnetic element provides rapid operation during high-current faults. This established protection method operates without requiring an external power supply for the trip unit.

The ABB 1SDA100731R1 adds a fully rated fourth pole with InN=100% In, allowing the neutral conductor to carry the same rated current as the phase conductors. Combined with adjustable 560–800 A thermal protection and 4000–8000 A instantaneous magnetic protection, this makes the XT6N suitable for high-current four-wire distribution systems requiring dependable phase and neutral switching.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Four-wire three-phase electrical distribution systems.
  • Main and sub-main electrical distribution.
  • High-current feeder and cable protection.
  • Systems requiring a fully rated neutral conductor.
  • Manufacturing and process plant electrical systems.
  • Commercial and infrastructure power distribution.
  • Transformer-fed distribution systems.
  • Fixed ABB Tmax XT6 installations requiring thermomagnetic protection.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Model / order code 1SDA100731R1
Extended product type XT6N 800 TMA 800-8000 4p F F InN=100%In
Product type Moulded-case circuit breaker (MCCB)
Frame size XT6
Breaking-capacity class N
Rated current 800 A
Rated uninterrupted current (Iu) 800 A
Number of poles 4
Neutral rating 100% In
Trip unit TMA thermomagnetic release
Thermal protection setting 560–800 A
Instantaneous protection setting (I3) 4000–8000 A
Ultimate short-circuit breaking capacity (Icu) at 415 V AC 36 kA
Rated operational voltage Up to 690 V AC
Rated insulation voltage (Ui) 1000 V
Rated impulse withstand voltage (Uimp) 8 kV
Rated short-time withstand current (Icw) 10 kA
Mounting execution Fixed
Terminal arrangement Front terminals
Standard IEC 60947-2
GTIN / EAN 8056221003568

Frequently Asked Questions

What is the ABB 1SDA100731R1?

The ABB 1SDA100731R1 is a Tmax XT6N 800 A 4-pole moulded-case circuit breaker with fixed mounting, front terminals, a TMA thermomagnetic trip unit and a fully rated neutral.

What does InN=100% In mean on the ABB 1SDA100731R1?

InN=100% In means the neutral pole is fully rated and can carry 100% of the circuit breaker's 800 A rated current, making the breaker suitable for four-wire systems where full neutral-current capacity is required.

What protection settings does the TMA trip unit provide?

The TMA trip unit provides adjustable thermal overload protection from 560–800 A and adjustable instantaneous magnetic short-circuit protection from 4000–8000 A.

What is the breaking capacity of the ABB XT6N 800?

The XT6N version has a rated ultimate short-circuit breaking capacity of 36 kA at 415 V AC.

Is the ABB 1SDA100731R1 a fixed circuit breaker?

Yes. The 1SDA100731R1 is a fixed 4-pole circuit breaker with front terminals, designed for installation in compatible low-voltage switchboards and distribution assemblies.

Trusted ABB Circuit Protection Technology

ABB SACE Tmax XT moulded-case circuit breakers combine compact construction, dependable fault interruption and configurable protection to safeguard industrial, commercial and infrastructure low-voltage electrical distribution systems.