1SDA100701R1 ABB Ekip G Dip LS/I In=400 4P XT5 Electronic Trip Unit

1SDA100701R1 ABB Ekip G Dip LS/I In=400 4P XT5 Electronic Trip Unit

ABB 1SDA100701R1 is a 400 A four-pole Ekip G Dip LS/I electronic trip unit for SACE Tmax XT5 circuit breakers, designed to provide overload and short-circuit protection for low-voltage generator applications.

SKU: 1SDA100701R1MPN: 1SDA100701R1
Price
List Price £732.73 ex VAT
Your Price (ex VAT) Save 25%
£549.55 25% OFF
You save £183.18 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £549.55
Trade pricing is personalised to your account

Manufacturer Lead Time

£549.55

Why Choose the ABB Ekip G Dip LS/I In=400 4p XT5 Trip Unit?

The ABB 1SDA100701R1 is an Ekip G Dip LS/I electronic trip unit designed for generator protection with four-pole ABB SACE Tmax XT5 moulded case circuit breakers. Rated at 400 A, it provides electronic overload and short-circuit protection for low-voltage AC generator circuits.

Part of ABB's Ekip G range, the release is specifically intended for generator protection, where fault-current characteristics can differ from those found in conventional utility-fed distribution systems. Its LS/I protection functions provide long-time overload protection together with short-circuit protection, helping safeguard generators and their associated electrical circuits.

The 1SDA100701R1 is a four-pole EL electronic release designed for the ABB SACE Tmax XT5 platform. Its loose or configurable construction allows it to be associated with a compatible four-pole XT5 breaking part, providing a flexible route to configuring a generator protection circuit breaker assembly.

Key Advantages

  • Purpose-designed electronic protection for generator applications.
  • Designed specifically for ABB SACE Tmax XT5 circuit breakers.
  • 400 A rated current for substantial generator circuits.
  • LS/I protection functionality for overload and short-circuit conditions.
  • Four-pole configuration for compatible three-phase and neutral generator systems.
  • Solid-state electronic protection provides accurate and repeatable operating characteristics.
  • Loose or configurable format supports association with a compatible XT5 breaking part.
  • Designed to meet IEC 60947-2 requirements.

Key Features

  • ABB Ekip G Dip LS/I electronic trip unit.
  • 400 A rated current (In).
  • Four-pole (4P) configuration.
  • EL electronic release.
  • Designed for AC circuits.
  • Long-time L protection against sustained overload conditions.
  • S/I short-circuit protection for fault-current conditions.
  • Specifically intended for generator protection.
  • Loose or configurable construction.
  • Suitable for the ABB SACE Tmax XT5 platform.
  • Suitable for low-voltage generator and generating-set applications.

Electronic Protection Designed for Generator Circuits

Generator-fed electrical systems can exhibit different short-circuit behaviour from conventional utility-fed networks, making appropriately selected circuit protection particularly important. The ABB Ekip G range is developed for generator applications, providing electronic protection functions suited to safeguarding generating equipment and the circuits connected to it.

With its 400 A rating, four-pole construction and LS/I protection functions, the 1SDA100701R1 is suited to compatible XT5 installations protecting generator outputs and associated distribution circuits. When associated with the appropriate ABB SACE Tmax XT5 breaking part, it provides a configurable protection solution for standby, prime-power and distributed generation systems.

Typical Applications

  • Low-voltage generator protection.
  • Standby generator installations.
  • Prime-power generating sets.
  • Emergency power systems.
  • Generator output circuit protection.
  • Four-pole generator distribution systems.
  • Industrial on-site generation.
  • Commercial and infrastructure backup power systems.

Technical Specifications

Series SACE Tmax XT
Frame size XT5
ABB order code 1SDA100701R1
Product type Electronic trip unit / protection release
Product main type Accessories for Tmax XT
Release Ekip G Dip LS/I
Release type EL electronic
Rated current (In) 400 A
Number of poles 4P
Current type AC
Protection functions LS/I
Circuit breaker application Generator protection
Configuration type Loose or configurable
Suitable for ABB SACE Tmax XT5
Standard IEC 60947-2
Product net weight 1.85 kg
Package dimensions (W × H × D) 120 × 180 × 225 mm
Package gross weight 2.014 kg
Minimum order quantity 1 piece
Customs tariff number 85389099
EAN / GTIN 8056221007771

Frequently Asked Questions

What is the ABB 1SDA100701R1 used for?

The ABB 1SDA100701R1 is an Ekip G Dip LS/I electronic trip unit designed for generator protection with compatible four-pole ABB SACE Tmax XT5 circuit breaker assemblies.

What is the rated current of the ABB Ekip G Dip 1SDA100701R1?

The electronic trip unit has a rated current of 400 A.

What does Ekip G Dip LS/I mean?

Ekip G identifies the release as part of ABB's generator protection range, while LS/I identifies its overload and short-circuit protection functions. The release is designed to provide electronic protection for generator-fed circuits.

Is the ABB 1SDA100701R1 a four-pole trip unit?

Yes. The 1SDA100701R1 is a four-pole (4P) electronic release for compatible ABB SACE Tmax XT5 circuit breaker assemblies, making it suitable for generator systems requiring a four-pole configuration.

Is the ABB 1SDA100701R1 a complete circuit breaker?

The 1SDA100701R1 is the electronic protection release. It is supplied in a loose or configurable format and is designed to be associated with a compatible ABB SACE Tmax XT5 breaking part as part of the required circuit breaker assembly.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT protection systems are used across generator, industrial and infrastructure applications where dependable low-voltage circuit protection and configurable electronic releases are required.