1SDA100667R1 ABB Ekip Dip LSIG In=250 XT5 4P

1SDA100667R1 ABB Ekip Dip LSIG In=250 XT5 4P

ABB 1SDA100667R1 Ekip Dip LSIG is a 250 A four-pole solid-state electronic trip unit for SACE Tmax XT5 circuit breakers providing long-time, short-time, instantaneous and ground-fault protection.

SKU: 1SDA100667R1MPN: 1SDA100667R1
Price
List Price £2,229.00 ex VAT
Your Price (ex VAT) Save 25%
£1,671.75 25% OFF
You save £557.25 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,671.75
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,671.75

Why Choose the ABB Ekip Dip LSIG In=250 XT5 4P?

The ABB Ekip Dip LSIG In=250 XT5 4p, order code 1SDA100667R1, is a four-pole solid-state electronic trip unit designed for use with compatible ABB SACE Tmax XT5 moulded case circuit breaker breaking parts. Rated at 250 A, it provides comprehensive LSIG protection for low-voltage AC power distribution systems.

As part of the ABB Ekip Dip range, this release combines long-time, short-time, instantaneous and ground-fault protection (LSIG). The overload setting is adjustable from 0.4–1 × In, while the short-circuit protection can be adjusted across a broad range to suit different distribution-system requirements and support selective protection strategies.

The 1SDA100667R1 uses a four-pole configuration and is designed specifically for the ABB Tmax XT5 platform. Its DIP-switch-based interface enables protection parameters to be configured directly on the release, providing a practical electronic protection solution for switchboards, feeders, distribution panels and industrial electrical installations.

Key Advantages

  • Comprehensive LSIG electronic protection for ABB Tmax XT5 circuit breakers.
  • 250 A rated current for low-voltage power distribution applications.
  • Four-pole configuration for three-phase and neutral distribution systems.
  • Adjustable overload protection from 0.4–1 × In.
  • Adjustable short-circuit protection with time-delay capability for improved protection coordination.
  • Ground-fault protection provides an additional layer of protection for electrical distribution systems.

Key Features

  • ABB Ekip Dip LSIG electronic release.
  • 250 A rated current (In).
  • Four-pole configuration.
  • Long-time (L) overload protection.
  • Short-time (S) short-circuit protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • Overload adjustment range: 0.4–1 × In.
  • Short-circuit adjustment range: 1–10 × In.
  • Time-delay capability for overload and short-circuit protection settings.
  • DIP-switch-based configuration for straightforward protection adjustment.
  • Electronic solid-state release technology.
  • Designed for use with a compatible ABB SACE Tmax XT5 breaking part.

Comprehensive Electronic Protection for Power Distribution

Electronic trip units monitor current conditions and command circuit-breaker operation when configured protection thresholds are exceeded. The ABB Ekip Dip LSIG combines long-time overload, short-time short-circuit, instantaneous short-circuit and ground-fault functions, providing comprehensive protection for cables, feeders and low-voltage distribution systems.

The Ekip Dip platform provides adjustable electronic protection through a straightforward DIP-switch interface. When the 1SDA100667R1 is combined with a compatible four-pole XT5 breaking part, it forms part of a flexible moulded case circuit-breaker solution suitable for industrial and commercial installations requiring configurable protection and coordination.

Typical Applications

  • Industrial low-voltage switchboards.
  • Three-phase and neutral distribution systems.
  • Main and sub-distribution panels.
  • Cable and feeder protection.
  • Manufacturing and process plant power distribution.
  • Commercial building electrical distribution.
  • Infrastructure and utility installations.
  • OEM switchgear and electrical panel assemblies.

Technical Specifications

Series Ekip Dip / SACE Tmax XT5
ABB order code 1SDA100667R1
EAN 8056221007436
Product type Solid-state electronic trip unit / protection release
Application Power distribution protection
Suitable for ABB SACE Tmax XT5
Rated current (In) 250 A
Current type AC
Number of poles 4
Protection functions LSIG
Long-time protection L
Short-time protection S
Instantaneous protection I
Ground-fault protection G
Overload setting range 0.4–1 × In
Short-circuit setting range 1–10 × In
Release Ekip Dip LSIG
Release technology Solid-state electronic
Compatible circuit-breaker frame XT5
Standard EN / IEC 60947-2
Customs tariff number 85389099

Frequently Asked Questions

What is the ABB 1SDA100667R1 used for?

The ABB 1SDA100667R1 is an Ekip Dip LSIG electronic trip unit designed for use with compatible four-pole ABB SACE Tmax XT5 breaking parts to provide comprehensive protection for low-voltage AC power distribution systems.

What is the rated current of the ABB Ekip Dip LSIG 1SDA100667R1?

The electronic trip unit has a rated current of 250 A and uses a four-pole configuration.

What does LSIG mean on the ABB Ekip Dip trip unit?

LSIG identifies the four principal protection functions: long-time (L), short-time (S), instantaneous (I) and ground-fault (G) protection.

What protection adjustment ranges are available?

The overload protection is adjustable from 0.4–1 × In, while short-circuit protection can be adjusted across a 1–10 × In range, providing flexibility for coordination with the protected distribution system.

Which circuit breaker is the ABB 1SDA100667R1 designed for?

The 1SDA100667R1 is designed for the ABB SACE Tmax XT5 platform and must be combined with a compatible four-pole XT5 breaking part to form a complete moulded case circuit breaker.

Advanced ABB Protection for Distribution Systems

ABB Ekip Dip electronic trip units provide configurable protection within the SACE Tmax XT platform, combining long-time, short-time, instantaneous and ground-fault functions for dependable protection of modern industrial and commercial low-voltage distribution systems.