1SDA100647R1 ABB Ekip Dip LIG 250 A XT5 3-Pole Trip Unit

1SDA100647R1 ABB Ekip Dip LIG 250 A XT5 3-Pole Trip Unit

ABB 1SDA100647R1 Ekip Dip LIG electronic trip unit rated at 250 A for 3-pole AC ABB Tmax XT5 moulded-case circuit breaker power distribution applications.

SKU: 1SDA100647R1MPN: 1SDA100647R1
Price
List Price £1,672.07 ex VAT
Your Price (ex VAT) Save 25%
£1,254.05 25% OFF
You save £418.02 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £1,254.05
Trade pricing is personalised to your account

Manufacturer Lead Time

£1,254.05

Why Choose the ABB 1SDA100647R1 Ekip Dip LIG Trip Unit?

The ABB 1SDA100647R1 is an advanced Ekip Dip LIG electronic trip unit designed for use with compatible ABB Tmax XT5 moulded-case circuit breakers. Rated at 250 A and configured for 3-pole AC applications, it provides adjustable electronic protection for low-voltage power distribution systems.

As part of the ABB SACE Tmax XT range, the Ekip Dip platform uses convenient DIP-switch adjustment to configure protection parameters. The LIG protection functions provide long-time overload, instantaneous short-circuit and earth-fault protection, helping safeguard cables, distribution equipment and connected electrical systems against damaging fault conditions.

With a rated current of 250 A, the 1SDA100647R1 is intended to be combined with a compatible 3-pole ABB Tmax XT5 circuit breaker unit. Its electronic protection settings include an adjustable overload range of 0.4–1 × In and adjustable short-circuit protection over a 1–10 × In range, with time-delay functionality supporting effective protection coordination.

Key Advantages

  • Electronic Ekip Dip LIG protection unit for ABB Tmax XT5 circuit breakers.
  • 250 A rated current for low-voltage power distribution applications.
  • 3-pole AC configuration suitable for three-phase electrical systems.
  • Provides long-time, instantaneous and earth-fault protection.
  • Adjustable overload protection from 0.4–1 × In.
  • Adjustable short-circuit protection from 1–10 × In with time-delay capability.

Key Features

  • ABB Ekip Dip LIG electronic release.
  • 250 A rated current (In).
  • 3-pole configuration.
  • AC current application.
  • Designed for compatible ABB Tmax XT5 moulded-case circuit breakers.
  • Long-time (L) overload protection.
  • Instantaneous (I) short-circuit protection.
  • Ground-fault (G) protection.
  • DIP-switch adjustment for protection settings.
  • Electronic release compliant with IEC 60947-2.

Adjustable Electronic Protection for Power Distribution

Electronic trip units continuously monitor current through a circuit breaker and initiate tripping when configured protection thresholds are exceeded. The ABB Ekip Dip platform provides adjustable electronic protection using straightforward DIP-switch settings, enabling protection characteristics to be matched to the requirements of the electrical distribution system.

The Ekip Dip LIG release combines long-time overload, instantaneous short-circuit and ground-fault protection. The adjustable settings of the 1SDA100647R1 make it suitable for coordinated protection of distribution circuits, cables and connected equipment when installed with a compatible ABB Tmax XT5 circuit breaker unit.

Typical Applications

  • Industrial low-voltage distribution switchboards.
  • Three-phase electrical distribution systems.
  • Commercial and infrastructure distribution panels.
  • Manufacturing and process plant power distribution.
  • Cable and feeder circuit protection.
  • ABB Tmax XT5 circuit breaker installations requiring adjustable electronic protection.

Technical Specifications

Series SACE Tmax XT
Product group T-Max XT 250 Range
Model / order code 1SDA100647R1
Product type Electronic circuit breaker trip unit
Release Ekip Dip LIG
Release type EL electronic release
Compatible frame Tmax XT5
Rated current (In) 250 A
Number of poles 3
Current type AC
Protection functions LIG
Overload adjustment range 0.4–1 × In
Short-circuit adjustment range 1–10 × In
Configuration type Loose or configurable
Standard IEC 60947-2
GTIN / EAN 8056221007238
Product net weight 1.395 kg

Frequently Asked Questions

What is the ABB 1SDA100647R1 used for?

The ABB 1SDA100647R1 is an Ekip Dip LIG electronic trip unit designed for use with compatible ABB Tmax XT5 moulded-case circuit breakers to provide adjustable protection for low-voltage power distribution circuits.

What is the rated current of the 1SDA100647R1?

The trip unit has a rated current of 250 A.

What does LIG mean on the Ekip Dip trip unit?

LIG identifies the unit's long-time (L), instantaneous (I) and ground-fault (G) protection functions, providing protection against overloads, short circuits and earth-fault conditions.

Which ABB circuit breaker is the 1SDA100647R1 designed for?

The 1SDA100647R1 is designed to be combined with a compatible 3-pole ABB Tmax XT5 circuit breaker unit.

Are the protection settings adjustable?

Yes. The Ekip Dip LIG provides adjustable electronic protection, including an overload setting range of 0.4–1 × In and short-circuit adjustment over a 1–10 × In range, with time-delay functionality.