1SDA100628R1 ABB TMG 320-1600 XT5 3P Thermomagnetic Trip Unit

1SDA100628R1 ABB TMG 320-1600 XT5 3P Thermomagnetic Trip Unit

ABB 1SDA100628R1 is a 320 A three-pole TMG thermomagnetic trip unit for SACE Tmax XT5 circuit breakers, providing adjustable thermal overload and 1600–3200 A magnetic short-circuit protection for generator applications.

SKU: 1SDA100628R1MPN: 1SDA100628R1
Price
List Price £526.15 ex VAT
Your Price (ex VAT) Save 25%
£394.61 25% OFF
You save £131.54 per unit
Manufacturer Lead Time Estimated Delivery 8 weeks
Get the best trade prices Trade exclusive

Create an online account to unlock exclusive pricing, special offers and more.

Create an online account Quick & easy setup
SUBTOTAL (EX VAT) £394.61
Trade pricing is personalised to your account

Manufacturer Lead Time

£394.61

Why Choose the ABB TMG 320-1600 XT5 3p Trip Unit?

The ABB 1SDA100628R1 is a TMG thermomagnetic trip unit designed for generator protection applications with three-pole ABB SACE Tmax XT5 moulded case circuit breakers. With a rated current of 320 A, it combines adjustable thermal overload protection with adjustable magnetic short-circuit protection for dependable protection of generators and associated low-voltage distribution circuits.

As part of the ABB SACE Tmax XT5 range, the TMG release provides straightforward thermomagnetic protection without requiring an electronic trip unit. Its thermal protection is adjustable from 0.7–1 × In, while the magnetic protection is adjustable from 5–10 × In, allowing the protection characteristics to be matched to the requirements of the generator and electrical installation.

The 1SDA100628R1 is a three-pole thermomagnetic protection release with a rated current of 320 A and a magnetic protection range of 1600–3200 A. Supplied as a separate trip unit, it must be combined with a compatible three-pole ABB XT5 breaking part to create the required moulded case circuit breaker assembly.

Key Advantages

  • Dedicated thermomagnetic generator protection for ABB SACE Tmax XT5 circuit breakers.
  • 320 A rated current for generator and power distribution applications.
  • Adjustable thermal overload protection from 0.7–1 × In.
  • Adjustable magnetic short-circuit protection from 5–10 × In.
  • 1600–3200 A magnetic protection range for configurable fault protection.
  • Three-pole configuration for three-phase electrical systems.
  • Thermomagnetic operation provides protection without requiring an electronic trip unit.
  • Designed for combination with compatible ABB XT5 breaking parts.

Key Features

  • ABB TMG thermomagnetic trip unit.
  • 320 A rated current (In).
  • Three-pole (3P) configuration.
  • Designed specifically for generator protection.
  • 0.7–1 × In adjustable thermal protection.
  • 5–10 × In adjustable magnetic protection.
  • 1600–3200 A magnetic short-circuit setting range.
  • Provides both overload and instantaneous short-circuit protection.
  • Separate protection release for use with a compatible XT5 breaking part.
  • Designed for the ABB SACE Tmax XT5 moulded case circuit breaker platform.

Reliable Thermomagnetic Protection for Generators

Generator circuits require protection against sustained overloads as well as high-current short-circuit faults. The ABB TMG release combines thermal and magnetic protection in a single trip unit, with independently adjustable operating ranges that allow the protection characteristics to be coordinated with the generator and downstream electrical system.

The adjustable thermal element protects against prolonged overcurrent conditions, while the magnetic element provides rapid operation when a substantial short-circuit current occurs. When combined with a compatible three-pole XT5 breaking part, the 1SDA100628R1 provides a practical protection solution for generators, standby power installations and associated low-voltage distribution systems.

Typical Applications

  • Low-voltage generator protection.
  • Standby and emergency generator systems.
  • Generator distribution switchboards.
  • Industrial power generation installations.
  • Commercial and infrastructure standby power systems.
  • Three-phase generator feeder protection.
  • Electrical systems requiring adjustable thermal and magnetic protection.

Technical Specifications

Series SACE Tmax XT5
ABB order code 1SDA100628R1
Product type Thermomagnetic trip unit / protection release
Release TMG
Release technology Thermomagnetic
Rated current (In) 320 A
Number of poles 3P
Protection application Generator protection
Thermal overload adjustment 0.7–1 × In
Thermal overload setting range 224–320 A
Magnetic adjustment 5–10 × In
Magnetic short-circuit setting range 1600–3200 A
Suitable for ABB SACE Tmax XT5
Rated operational voltage 690 V AC
Net weight approx. 1.35 kg
Package dimensions (L × W × H) 225 × 120 × 180 mm
Minimum order quantity 1 piece
Country of origin Italy
EAN / GTIN 8056221007047

Frequently Asked Questions

What is the ABB 1SDA100628R1 used for?

The ABB 1SDA100628R1 is a TMG thermomagnetic trip unit designed for use with compatible three-pole ABB SACE Tmax XT5 circuit breaker breaking parts, primarily providing overload and short-circuit protection for generator applications.

What is the rated current of the ABB TMG 1SDA100628R1?

The TMG trip unit has a rated current of 320 A.

What is the thermal protection adjustment range?

The thermal overload protection is adjustable from 0.7–1 × In, corresponding to approximately 224–320 A with the 320 A rated trip unit.

What is the magnetic protection adjustment range?

The magnetic short-circuit protection is adjustable from 5–10 × In, corresponding to 1600–3200 A.

Is the ABB 1SDA100628R1 a complete circuit breaker?

No. The 1SDA100628R1 is a separate thermomagnetic protection trip unit designed to be combined with a compatible three-pole ABB SACE Tmax XT5 breaking part to form the required circuit breaker assembly.

Trusted by Electrical Professionals Worldwide

ABB SACE Tmax XT circuit breaker systems are used across generator protection, industrial power distribution and infrastructure applications, providing flexible protection and dependable performance for modern low-voltage electrical installations.